Product datasheet XB5AW36M5 Characteristics blue flush complete illum pushbutton 22 spring return 1NO+1NC 220...240V Main Range of product Harmony XB5 Product or component type Complete illuminated push-button Device short name XB5 Bezel material Plastic Fixing collar material Plastic Mounting diameter 22 mm Sale per indivisible quantity 1 Shape of signaling unit head Round Type of operator Spring return Operator profile Blue flush unmarked Operator additional information With plain lens Contacts type and composition 1 NO + 1 NC Contact operation Slow-break Connections - terminals Screw clamp terminals : <= 2 x 1.5 mm with cable end conforming to EN/IEC 60947-1 Screw clamp terminals : 1 x 0.22...2 x 2.5 mm without cable end conforming to EN/IEC 60947-1 Light source Protected LED Bulb base Integral LED Us rated supply voltage 220...240 V AC, 50/60 Hz Complementary Height 42 mm Width 30 mm Depth 57 mm Terminals description ISO n1 (13-14)NO (21-22)NC Product weight 0.056 kg Resistance to high pressure washer 7000000 Pa at 55 C,distance: 0.1 m Contacts usage Standard contacts Nov 07, 2017 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsPositive opening With positive opening conforming to EN/IEC 60947-5-1 appendix K Operating travel 1.5 mm (NC changing electrical state) 2.6 mm (NO changing electrical state) 4.3 mm (total travel) Operating force 3.5 N (NC changing electrical state) 3.8 N Mechanical durability 10000000 cycles Tightening torque 0.8...1.2 N.m conforming to EN 60947-1 Shape of screw head Cross head compatible with Philips no 1 screwdriver Cross head compatible with pozidriv No 1 screwdriver Slotted head compatible with flat 4 mm screwdriver Slotted head compatible with flat 5.5 mm screwdriver Contacts material Silver alloy (Ag/Ni) Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 Ith conventional free air thermal 10 A conforming to EN/IEC 60947-5-1 current Ui rated insulation voltage 600 V (degree of pollution: 3) conforming to EN/IEC 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1 Ie rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 Electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C Electrical reliability < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4 < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4 Signalling type Steady Supply voltage limits 195...264 V AC Current consumption 14 mA Service life 100000 h at rated voltage and 25 C Surge withstand 1 kV conforming to IEC 61000-4-5 Environment Protective treatment TH Ambient air temperature for storage -40...70 C Ambient air temperature for operation -40...70 C Overvoltage category Class II conforming to IEC 60536 IP degree of protection IP69 IP67 IP66 conforming to IEC 60529 IP69K NEMA degree of protection NEMA 13 NEMA 4X IK degree of protection IK05 conforming to IEC 50102 Standards EN/IEC 60947-5-1 CSA C22.2 No 14 JIS C 4520 EN/IEC 60947-1 UL 508 EN/IEC 60947-5-4 Product certifications RINA GL BV 2