Product data sheet XC2JC10111 Characteristics limit switch XC2-J - roller lever - 1 C/O Main Range of product OsiSense XC Series name Special format Product or component Limit switch type Product specific appli- For severe applications cation Device short name XC2J Body type Fixed Head type Rotary head Material Metal Movement of operating Rotary head Type of operator Thermoplastic roller lever Switch actuation By 30 cam Type of approach Lateral approach, 2 directions Number of poles 1 Contacts operation Snap action Minimum torque for 0.3 N.m tripping Maximum actuation 1.5 m/s speed Complementary Fixing mode By the body Electrical connection Screw-clamp terminals, 1 x 0.5...2 x 2.5 mm Cable entry 1 entry incorporating cable gland, cable outer diameter: 6...13.5 mm Contacts insulation form Za Contacts material Silver plated contacts Positive opening Without Minimum actuation speed 0.001 m/min Contact code designation AC-15 A300(Ue = 240 V, Ie = 3 A) Ithe = 10 A EN/IEC 60947-5-1 DC-13 Q300(Ue = 250 V, Ie = 0.27 A) EN/IEC 60947-5-1 Ui rated insulation voltage 500 V conforming to IEC 60947-5-1 500 V conforming to NF C 20-040 group C 300 V conforming to CSA C22.2 No 14 Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3 <= 25 MOhm conforming to NF C 93-050 method A Short circuit protection 10 A by cartridge fuse, type gG Electrical durability 5000000 cycles DC-13, 120 V 4 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles DC-13, 24 V 10 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles DC-13, 48 V 7 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C Mechanical durability 30000000 cycles Width 40 mm Height 143...183 mm Depth 65 mm Product weight 0.62 kg Terminals description ISO n1 (13-14-11-12)OF Feb 5, 2018 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Environment Shock resistance 25 gn for 18 ms conforming to IEC 60068-2-27 Vibration resistance 10 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 IP degree of protection IP65 conforming to IEC 60529 IP657 conforming to NF C 20-010 IK degree of protection IK08 Class of protection against electric shock Class I conforming to IEC 60536 Class I conforming to NF C 20-030 Ambient air temperature for operation -25...70 C Ambient air temperature for storage -40...70 C Protective treatment TC Product certifications CSA DEMKO NEMKO Standards EN/IEC 60947-5-1 IEC 60337-1 UL 508 VDE 0660-200 CSA C22.2 No 14 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1014 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product end of life instructions Need no specific recycling operations 2