Product data sheet XCSDMP5005 Characteristics coded magnetic switch XCSDMP - 1 NC + 2 NO - 1 NO staggered - 5m Product availability: Stock - Normally stocked in distribution facility Main Range of product Preventa Safety detection Product or component Coded magnetic switch type Component name XCSDMP Design Rectangular, standard Size 88 x 25 x 13 mm Contacts type and com- 1 NC + 2 NO position Contact operation 1 NO staggered Material Plastic Electrical connection Pre-cabled Cable composition 6 x 0.25 mm Cable length 16.4 ft (5 m) Number of poles 3 Approach directions 3 directions System Voltage 24 V DC Ui rated insulation volt- 100 V DC age Complementary Sa assured operating distance 0.31 in (8 mm) Sar assured tripping distance 0.79 in (20 mm) Ie rated operational current <= 100 mA Uimp rated impulse withstand voltage 2.5 kV conforming to EN/IEC 60947-5-1 Resistance across terminals 10 Ohm Short-circuit protection 500 mA external cartridge fuse type gG (gl) Contacts material Rhodium Electrical durability 1200000 cycles Maximum switching voltage DC Switching capacity in mA 0.1...100 mA Insulation resistance 1000 MOhm Breaking capacity 10 VA Switching frequency 150 Hz Safety level Can reach category 4 (with the appropriate monitoring system and correctly wired) conforming to EN/ISO 13849-1 Can reach PL = e (with the appropriate monitoring system and correctly wired) conforming to EN/ISO 13849-1 Can reach SIL 3 (with the appropriate monitoring system and correctly wired) con- forming to EN/IEC 61508 Safety reliability data B10d = 50000000 (value given for a life time of 20 years limited by mechanical or contact wear) Enclosure material Thermoplastic PBT Cable material PVC Depth 0.51 in (13 mm) Height 3.46 in (88 mm) Width 0.98 in (25 mm) Product weight 0.4 lb(US) (0.18 kg) Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Environment Standards ISO 14119 UL 508 EN/IEC 60204-1 EN/ISO 12100 EN/IEC 60947-5-1 CSA C22.2 No 14 Product certifications BG UL CSA Protective treatment TH Ambient air temperature for operation -13...185 F (-25...85 C) Ambient air temperature for storage -40...185 F (-40...85 C) Vibration resistance 10 gn (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 30 gn 11 ms conforming to IEC 60068-2-27 Sensitivity to magnetic fields <= 0.3 mT Electrical shock protection class Class II conforming to EN/IEC 61140 IP degree of protection IP66 conforming to IEC 60529 IP67 conforming to IEC 60529 Ordering and shipping details Category 22411 - LIMIT SWITCHES,IEC,XCKJ Discount Schedule T GTIN 00785901435914 Nbr. of units in pkg. 1 Package weight(Lbs) 0.76000000000000001 Returnability Y Country of origin FR Offer Sustainability RoHS (date code: YYWW) Compliant - since 0729 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference not containing SVHC above the threshold California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and - - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 2