Product datasheet XCSE7533 Characteristics metal safety switch XCSE - 2NC+1NO-slow break- 2entries tapped 1/2 NPT-110/120V Main Range of product Preventa Safety detection Product or component type Safety switch Component name XCSE Design Rectangular Material Metal Head type Key operated turret head Contacts type and composition 2 NC + 1 NO Contacts operation Slow-break, break before make Solenoid contacts type and 1 NC + 1 NO (slow-break, simultaneous) composition Cable entry 2 entries tapped 1/2 NPT Electromagnet interlocking Locking on energisation and unlocking on de-energisation of solenoid Us rated supply voltage 110/120 V (- 20...10 %) Electrical connection Terminal, 1 x 0.5...2 x 1.5 mm with or without cable end Number of poles 3 Locking options description With interlocking, locking by solenoid Local signalling 2 LEDs green or orange (guard open/guard closed and locked) Signalling circuit voltage 110/240 V (voltage limits: 95...264 V) Complementary Positive opening With NC contact Supply voltage type AC/DC Supply frequency 50/60 Hz Load factor 1 Power consumption in VA 10 VA (inrush) 10 VA (sealed) Signalling circuit type AC Signalling circuit consumption 7 mA Mar 09, 2017 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsMechanical durability >= 1000000 cycles Minimum actuation speed 0.01 m/s Maximum actuation speed 0.5 m/s Ie rated operational current 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 Ithe conventional enclosed thermal 6 A current Ui rated insulation voltage 250 V for signalling circuit conforming to EN/IEC 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 Protection type Overvoltage protection for signalling circuit Short circuit protection 10 A cartridge fuse type gG (gl) Actutr forcible withdrawal rtc 2000 N Actuator force for extraction >= 20 N Operating rate 10 cyc/mn for maximum durability Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Safety reliability data B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) Body material Zamak Head material Zamak Depth 44 mm Height 146 mm Width 98 mm Product weight 1.14 kg Environment Standards EN/IEC 60947-5-1 EN/IEC 60204-1 UL 508 EN 1088/ISO 14119 CSA C22.2 No 14 EN/ISO 12100 Product certifications CSA UL Protective treatment TC Ambient air temperature for operation -25...40 C Ambient air temperature for storage -40...70 C Vibration resistance 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 10 gn for 11 ms conforming to IEC 60068-2-27 Class of protection against electric Class I conforming to EN/IEC 60536 shock IP degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1150 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold 2