Product datasheet xmlg006d21 Characteristics Main Range of product OsiSense XM Product or component type Electronic pressure sensors Pressure sensor type Pressure transmitter Pressure sensor name XMLG Pressure sensor size 87.02 psi (6 bar) Fluid connection type G 1/4A (male) conforming to DIN 3852-E Controlled fluid Air (5...257 F (-15...125 C)) Corrosive fluid (5...257 F (-15...125 C)) Hydraulic oil (5...257 F (-15...125 C)) Fresh water (0...125 C) Type of output signal Analogue Analogue output function 4...20 mA, 2 wires Electrical connection 3 pins 1 male connector M12 Us rated supply voltage 12 V DC, voltage limits: 8...33 V 24 V DC, voltage limits: 8...33 V Quantity per set Set of 1 Type of packing Individual Diameter 0.9 in (22.8 mm) Complementary Pressure setting range 0...87.02 psi (0...6 bar) Maximum permissible accidental pressure 195.8 psi (13.5 bar) Destruction pressure 217.56 psi (15 bar) Local display Without Electrical circuit type Control circuit Current consumption < 20 mA Materials in contact with fluid Ceramic FPM (Viton) Stainless steel type AISI 303 Operating position Any position Protection type Load short-circuit Reverse polarity Surge withstand 1 kV (42 Ohm) conforming to EN/IEC 61000-4-5 500 kV (12 Ohm) conforming to EN/IEC 61000-4-5 Uimp rated impulse withstand voltage 0.5 kV Response time on output < 2 ms Drift of the sensitivity +/- 0.015 % of measuring range/C Drift of the zero point +/- 0.015 % of measuring range/C Measurement accuracy +/- 0.3 % of the measuring range Repeat accuracy +/- 0.1 % of the measuring range Mechanical durability >= 10000000 cycles Product weight 0.21 lb(US) (0.095 kg) Height 58.1 mm Length 1.91 in (48.5 mm) Scale type Fixed differential Environment standards CE EN/IEC 61326-2-3 product certifications UL 508 CSA C22.2 No 14 1 / 3 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.EAC protective treatment TC ambient air temperature for operation 5...185 F (-15...85 C) ambient air temperature for storage -40...185 F (-40...85 C) vibration resistance 20 gn (f = 9...2000 Hz) conforming to EN/IEC 60028-2-6 shock resistance 25 gn 11 ms conforming to EN/IEC 60068-2-27 resistance to electrostatic discharge 15 kV (in air) conforming to EN/IEC 61000-4-2 8 kV (on contact) conforming to EN/IEC 61000-4-2 resistance to electromagnetic fields 182.88 V/yd (200 V/m) (80...1000 Hz) conforming to EN/IEC 61000-4-3 resistance to fast transients 4 kV conforming to EN/IEC 61000-4-4 resistance to conducted disturbances 30 V (0.15...80 Hz) conforming to EN/IEC 61000-4-6 resistance to magnetic fields 30 A/m conforming to EN/IEC 61000-4-8 IP degree of protection IP66 conforming to EN/IEC 60529 IP67 conforming to EN/IEC 60529 NEMA degree of protection NEMA 4 Offer Sustainability Not Green Premium product Not Green Premium product Compliant - since 0627 - Schneider Electric declaration Compliant - since 0627 - Schneider Electric declaration of conformity of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold WARNING: This product can expose you to chemicals WARNING: This product can expose you to chemicals including: including: Diisononyl phthalate (DINP), which is known to the State Diisononyl phthalate (DINP), which is known to the State of California to cause of California to cause cancer, and cancer, and Di-isodecyl phthalate (DIDP), which is known to the State Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth of California to cause birth defects or other reproductive defects or other reproductive harm. harm. For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months Dimensions Wiring Diagram 2-Wire Technique (4-20 mA) Output Curves 2 / 3