Product data sheet XMLP6K0PP13 Characteristics pressure transmitter - XMLP - 6000psi - 1/4 18NPT - 0,5..4,5V - Packard - set 1 Main Range of Product OsiSense XM Product or Component Electronic pressure sensors Type Pressure sensor type Pressure transmitter Pressure sensor name XMLP Electrical circuit type Control circuit Pressure Rating 6000psi (41368.54kPa) Local display Without Controlled fluid Fresh water 32248F (0120C)) Air -22248F (-30120C)) Hydraulic oil -22248F (-30120C)) Gas -22248F (-30120C)) Refrigeration fluid -22248F (-30120C)) Fluid connection type 1/4 - 18 NPT (male) Electrical connection 1 male connector Packard Metripack 150 3 pins Us rated supply 5 V DC SELV 4.55.5V) voltage Current Consumption < 5 mA Type of output signal Analogue Analogue output 0.5...4.5 V, 3-wire function Quantity per Set Set of 1 Type of Packing Individual Complementary Pressure setting range 06000psi (0.0041368.54kPa) Maximum permissible accidental pressure 11600psi (79979.18kPa) Destruction pressure 24000psi (165474.17kPa) Materials in contact with fluid Stainless steel type AISI 304 Stainless steel type 17-4PH Operating position Any position Protection Type Load short-circuit Reverse polarity Electromagnetic compatibility Susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...1000 MHz Electrical fast transient/burst immunity test EN/IEC 61000-4-4 2 kV 1.2/50 s shock waves immunity test EN/IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm Radiated RF fields EN/IEC 61000-4-6 10 V 0.15...80 MHz Electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact Uimp rated impulse withstand voltage 0.5kV Response time on output < 5 ms 92 % of full scale Measurement accuracy +/- 0.5 % of the measuring range Resolution Infinity Drift of the sensitivity +/- 0.02 % of measuring range/K Drift of the zero point +/- 0.02 % of measuring range/K Long term stability +/- 0.2 % of the measuring range Mechanical durability 10000000cycles Net Weight 0.11lb(US) (0.05kg) Diameter 1.18in (30mm) Length 1.46in (37mm) Scale type Fixed differential Jan 22, 2022 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Environment Standards CE EN/IEC 61326-1 Product Certifications CULus RCM EAC Protective treatment TC Ambient air temperature for operation -22212F (-30100C) Ambient Air Temperature for Storage -22212F (-30100C) Vibration resistance 20 gn 102000Hz) EN/IEC 60068-2-64 Shock resistance 25 gn 11ms EN/IEC 60068-2-27 IP degree of protection IP65 conforming to EN/IEC 60529 IP67 conforming to EN/IEC 60529 Ordering and shipping details Category 21561-XMLK,XMLP PRESSURE TRANSMITTERS Discount Schedule DS2 GTIN 03389119076272 Package weight(Lbs) 0.14lb(US) (0.063kg) Returnability No Country of origin DE Packing Units Package 1 Height 0.410dm Package 1 width 0.640dm Package 1 Length 0.940dm Contractual warranty Warranty 18 months 2