Product data sheet XMPA12B2142 Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product OsiSense XM Pressure sensor type Electromechanical pressure sensor Pressure sensor name XMP Pressure sensor size 12 bar Fluid connection type G 1/4 (female) conforming to ISO 228 Controlled fluid Air (0...70 C) Fresh water (0...70 C) Sea water (0...70 C) Cable entry 2 entries incorporating Pg 13.5 plastic cable gland, cable outer diameter: 9...13 mm conforming to NF C 68-300 Contacts type and com- 2 NC snap action position Product specific appli- - cation Pressure switch type of Regulation between 2 thresholds operation Electrical connection Screw-clamp terminals, clamping capacity: mini- mum : 2 x 4 mm Electrical circuit type Power circuit Scale type Adjustable differential Local display Without Sale per indivisible 1 quantity Complementary Adjustable range of switching point on falling pres- 0.3...10.3 bar sure Adjustment range high setting 1.3...12 bar Possible differential minimum at low setting 1 bar Possible differential minimum at high setting 1.7 bar Possible differential maximum at high setting 8.4 bar Destruction pressure 30 bar Type of decompression valve Without Control type Without Terminal block type 4 terminals Pressure actuator Diaphragm Materials in contact with fluid Canvas covered nitrile Chromated zinc alloy Enclosure material PA impregnated with fibreglass Operating position Any position Operating rate 10 cyc/mn Repeat accuracy < 3.5 % Ui rated insulation voltage 500 V conforming to EN/IEC 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1 Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3 <= 25 MOhm conforming to NF C 93-050 method A Jun 12, 2017 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Electrical durability 1000000 cycles (1.5 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) 500000 cycles (3 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) 600000 cycles (1.5 kW, operating rate: 10 cyc/mn, load factor: 0.4, 230 V AC 3 phases) 700000 cycles (2.2 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) Mechanical durability 1000000 cycles Setting Knurled knob and nut Terminals description ISO n1 (1-2)NC (3-4)NC Depth 98 mm Height 106 mm Width 57 mm Environment Product certifications EAC Standards CE EN/IEC 60947-4-1 Ambient air temperature for operation -25...70 C Ambient air temperature for storage -40...70 C Vibration resistance 3 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 50 gn conforming to IEC 60068-2-27 Class of protection against electric shock Class I conforming to IEC 60536 IP degree of protection IP54 conforming to EN/IEC 60529 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0627 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product end of life instructions Need no specific recycling operations 2