Product data sheet XPSAC5121 Characteristics module XPSAC - Emergency stop - 24 V AC DC Product availability: Stock - Normally stocked in distribution facility Main Range of product Preventa Safety automation Product or component Preventa safety module type Safety module name XPSAC Safety module applica- For emergency stop and switch monitoring tion Function of module Switch monitoring Emergency stop Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061 Safety reliability data DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 210.4 years conforming to EN/ISO 13849-1 PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 Type of start Unmonitored Connections - terminals Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm flexible cable with cable end, without bezel Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 1.5 mm flexible cable with cable end, with bezel Captive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 1 mm flexible cable with cable end, with- out bezel Captive screw clamp terminals, clamping capacity: 2 x 0.5...2 x 1.5 mm flexible cable with cable end, with double bezel Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm flexible cable without cable end Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm solid cable without cable end Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm flexible cable without cable end Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm solid cable without cable end Output type Relay instantaneous opening 3 NO, volt-free Number of additional 1 solid state output circuits Us rated supply volt- 24 V AC (- 20...10 %) age 24 V DC (- 20...20 %) Complementary Supply frequency 50/60 Hz Power consumption in W <= 1.2 W DC Power consumption in VA <= 2.5 VA AC Uc control circuit voltage 24 V Breaking capacity C300: 180 VA, AC-15 (holding) relay output C300: 1800 VA, AC-15 (inrush) relay output Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output Output thermal current 6 A per relay relay output Ith conventional free air thermal current 10.5 A Associated fuse rating 4 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Minimum output current 10 mA relay output Minimum output voltage 16 V for relay output Response time on input open <= 100 ms Ui rated insulation voltage 300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1 300 V (degree of pollution: 2) conforming to IEC 60947-5-1 Uimp rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 Local signalling 2 LEDs Current consumption 40 mA at 24 V DC (on power supply) 90 mA at 24 V AC (on power supply) Mounting support 35 mm symmetrical DIN rail Product weight 0.35 lb(US) (0.16 kg) Environment Standards EN/ISO 13850 EN/IEC 60947-5-1 EN 1088/ISO 14119 EN 60204-1 Product certifications TV UL CSA IP degree of protection IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 Ambient air temperature for operation 14...131 F (-10...55 C) Ambient air temperature for storage -13...185 F (-25...85 C) Ordering and shipping details Category 22477 - SAFETY MODULES (PREVENTA) Discount Schedule SAF2 GTIN 00785901420569 Nbr. of units in pkg. 1 Package weight(Lbs) 0.41999999999999998 Returnability Y Country of origin ID Offer Sustainability California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause can- cer and birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 2