Non resettable fuses MGA www.schurter.com/PG01 2 Surface Mount Fuse, 3.2 x 1.55 mm, Super-Quick-Acting FF, 125 VAC, 125 VDC, 150 C UL 248-14 125 VAC 125 VDC Super-Quick-Acting FF Description Applications - Max. ambient temperature 150 C - Medical equipment - Hermetically sealed and robust construction - Military - Thin-film technology References - Impermeable to potting compound used to achieve hermetic seal for Packaging Details use in intrinsically safe applications according to ATEx and IECEx re- Weblinks quirements. pdf-datasheet, html-datasheet, General Product Information, Approvals, Standards CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop, - UL 248-14 SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for - CSA C22.2 no. 248.14 product Approvals - UL File Number: E41599 Technical Data Rated Voltage 32 - 125 VAC, 125 VDC Soldering Methods Reflow, Wave Rated current 0.2 - 5 A Solderability 245 C / 3 sec acc. to IEC 60068-2-58, Test Td Breaking Capacity 50 A Resistance to Soldering Heat 260 +0/-5 C / 30 sec acc. to IPC/JE- Characteristic Super-Quick-Acting FF DEC J-STD-020D, Level 1 Mounting PCB,SMT Life Test MIL-STD-202, Method 108A Admissible Ambient Air Temp. -55 C to 150 C 1000h 0.60 x In 70C Climatic Category 55/150/21 acc. to IEC 60068-1 Load Humidity Test MIL-STD-202, Method 103B Material: Housing Ceramic 0.1 x In 0.85 r.H. 85C Material: Terminals Tin-Plated Nickel Moisture Resistance Test MIL-STD-202, Method 106E Unit Weight 0.03 g (50 cycles in a temp./mister chamber) Storage Conditions 0 C to 60 C, max. 70% r.h. Terminal Strength MIL-STD-202, Method 211A Product Marking none (Deflection of board 1 mm for 1 minute) Thermal Shock MIL-STD-202, Method 107D (200 air-to-air cycles from -55 to +125C) Resistance to Solvents MIL-STD-202, Method 215A Flammability min. UL 94V-1 (acc. to EIA/IS-722, Test 4.12) Dimension 3.2 mm Reflow soldering pads 0.51.55 1.5 1.1 3.2 Fuses 1 1.55 2Non resettable fuses MGA www.schurter.com/PG01 2 Pre-Arcing Time Rated Current In 1.0 x In min. 2.5 x In max. 0.2 A - 5 A 4 h 5 s Time-Current-Curves 100000 10000 1000 100 10 1 0.1 0.01 0.001 10 1 Multiple of Rated Current In All Variants Rated Cur- Rated Vol- Rated Vol- Breaking Voltage Drop Cold Resi- Melting It 4.0 Order Number rent A tage VAC tage VDC Capacity 1.0 In typ. stance typ. In typ. As mV m 0.2 125 125 1) 258 1020 0.0008 l 3410.0021.xx 0.25 125 125 1) 250 800 0.0009 l 3410.0022.xx 0.375 125 125 1) 165 361 0.0037 l 3410.0025.xx 0.5 125 125 1) 150 247 0.0042 l 3410.0027.xx 0.75 125 125 1) 100 115 0.01 l 3410.0029.xx 1 125 125 1) 124 98.7 0.035 l 3410.0031.xx 1.5 125 125 1) 105 56 0.064 l 3410.0033.xx 2 125 125 1) 98 39 0.089 l 3410.0035.xx 2.5 125 125 1) 90 29.5 0.15 l 3410.0036.xx 3 125 125 1) 88 24.1 0.18 l 3410.0037.xx 4 63 125 2) 83.5 17 0.23 l 3410.0240.xx 5 32 125 3) 90 13.5 0.45 l 3410.0141.xx Most Popular. Availability for all products can be searched real-time: