Power entry modules without line filter
GSF1
www.schurter.com /PG05
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole
Screw-On Version Snap-in version Pick & Place Version
C14
70 C
Description Characteristics
- Panel Mount :
- PCB mount with snap-in or screw-on feet
Sandwich/rear-side Suitable for automatic PCB assembling
- All single elements are already wired
- 2 Functions :
- Fuseholder on the inside of the equipment prevents accidental use of
Appliance Inlet Protection class I , with or without Fuseholder for fuse-
incorrect fuse-links by the user
links 5 x 20 mm on the rear-side 1- or 2-pole
- With or without rear-side insulation cover
- For PCB mounting
- Blister tray as optional packaging variant
- Pick and place version
- Suitable for use in equipment according to IEC/UL 60950
Approvals
Other versions on request
- Approval Reference Type: GSF1
- Ground terminal with quick-connect terminal 6,3 x 0,8 mm
- VDE Certificate Number: 40024857
- Ground terminal with solder terminal
- UL File Number: E93617, E96454
- For protection class II
- CSA Certification Record: 38456
- CCC File Number: 2006010204183182
Weblinks
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz appliance inlet/-outlet C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
Ratings UL/CSA 10 A / 250 VAC; 60 Hz
conditions) pin-temperature 70 C, 10 A,
without fuseholder 16A (UL)
Protection Class I
Dielectric Strength > 3 kVAC between L-N
Fuseholder optional, 1 or 2 pole, Shocksafe cate-
> 4 kVAC between L/N-PE
gory PC2 acc. to IEC 60127-6,
(1 min/50 Hz)
for fuse-links 5 x 20 mm
Allowable Operation Tempe- -25 C to 70 C
Rated Power Acceptance @ 5 x 20: 3.15 W (1 pole)/ 2.5 W (2-pole)
rature
Ta 23 C per pole
IP-Protection from front side IP 40 acc. to IEC 60529
Power Acceptance @ Ta > Admissible power acceptance at higher
Insulation cover Suitable for appliances with protection
23C ambient temperature see derating cur-
class I acc. to IEC 61140
ves
Terminal For PCB mounting
Panel Thickness S Snap-in: 1.5/2/2.5/3 mm
Material: Housing Thermoplastic, black, UL 94V-0
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in General Product
Information
Connectors 1Power entry modules without line filter
GSF1
www.schurter.com /PG05
Dimensions [mm]
with insulation cover
19.3
6
AS
max. R4.5
26.8
0.1
30.3
1.5
11.5
29.9
15.9
34
A = 6 mm for standard versions for mounting from rear-side
A = 5 mm for pick and place versions
S = 0 mm for mounting from rear-side
27
max. R2
0.1
27.7
27.5
A = 6 mm for standard versions for sandwich mounting
A = 5 mm for pick and place versions
Drilling diagrams
without fuseholder with 1-pole fuseholder with 2-pole fuseholder Pick and Place versions
without / with 1-pole or
18.1 9.05 12.7 25.4
2-pole fuseholder
0.10
25.4
1.4 1.4 1.4
1.4 3.5 1.6
D1 1.6 D1 1.6 D1 1.6
5.8 1.6
27 27 27 0.05 0.05
2.3 1.6 2.3
0.10
26.7
D1 for snap-in mounting = 6 0.05 D1 for snap-in mounting = 6 0.05 D1 for snap-in mounting = 6 0.05
D1 for self-tapping screw = 3.6 0.1 D1 for self-tapping screw = 3.6 0.1 D1 for self-tapping screw = 3.6 0.1
1* only for protection class II
Derating Curves
1-pole 2-pole
3.15 2.5
2.0
2.5
I = 1.0 I
n
I = 1.0 I
2.0 n
1.5
I = 0.7 I
n
I = 0.7 I
n
1.5
I = << I
n
I = << I 1.0
n
1.0
0.5
0.5
0.0
0.0
020406080100
020406080 100
Ambient Air Temperature T C Ambient Air Temperature T C
a a
2 Connectors
Admissible Power Acceptance in Watt 12
9.9
21.9
24.45
9.9
19.35
0.1
5.5
19.7
Admissible power acceptance in Watt
per pole
9.9
25.5
5.5
0.05
10.9
2.5
1*
0.05
6.5
0.1
22.3