General Purpose Passive Oscilloscope Probes Pomona Models 4550B, 5795A, 5800A, 5803A, 5806A, 5827A, 6049A, 6069A, 6265, 6266, SP150B FEATURES: Pomonas latest design of Passive Oscilloscope probes feature a one piece (monolithic) design for robust probe life. Probe bandwidth ratings are specified as a system bandwidth. System bandwidth includes both probe and oscilloscope together as a system. The result is a probe frequency response that can essentially can be considered transparent. For ease of use, Readout Actuator for probe attenuation sensing and a Ground Reference switch are featured on some probe models. Full set a accessories are included with each probe. All probes meet IEC1010-2-031, 300V, CAT I Model : Attention: System System Compensation Voltage Input Res. Input Cap. Readout Gnd. Bandwidth Risetime Range (pf.): Max. (M ) (pf.): Actuator Ref.: (3dB) MHz.: ns (Note 2) Pin: 4550B X1/X10 15/100 23.33/3.5 10-60 300 1/10 64/10.5 X 5795A X10 100 3.5 10-60 300 10 9.5 5800A X1 30 11.66 N/A 300 1 57 5803A X10 200 1.75 10-60 300 10 10 5806A X1/X10 20/200 17.5/1.75 10-60 300 1/10 77/11.5 X 5827A X100 200 1.75 15-50 300 10 5.5 6049A X10 150 2.33 10-30 300 10 10.5 6069A X10 250 1.75 10-30 300 10 10 6265 X10 60 5.83 10-60 300 10 10.5 6266 X1/X10 20/60 17.5/5.83 10-60 300 1/10 65/11 X SP150B X1/X10 15/150 23.33/2.33 10-60 300 1/10 50/15 X 1.) Measurements based on 1M Ohm, 20 pf. Oscilloscope. All dimensions are in inches. Tolerances (except noted): .xx = .02 (,51 mm), .xxx = .005 (,127 mm). All specifications are to the latest revisions. Specifications are subject to change without notice. Registered trademarks are the property of their respective companies. Made in USA 6/9/99 PomonaACCESS 90474 (800) 444-6785 or (425) 446-6010 Sales: 800-490-2361 Fax: 888-403-3360 SY/EH/LS More drawings available at www.pomonaelectronics.com Technical Assistance: 800-241-2060 S: Engineering Release DataSheets FlukeDataSheet d4550B-SP150B 6 01.doc Page 1 of 6 General Purpose Passive Oscilloscope Probes Pomona Models 4550B, 5795A, 5800A, 5803A, 5806A, 5827A, 6049A, 6069A, 6265, 6266, SP150B 2.) Maximum probe input voltage is limited to the lesser of 300VDC (includes AC peak to 1.3MHz.) or on X1, to the driven equipments input rating. * Oscilloscope Model 5827 has a cable length of 2.0 Meters. Model : Attention: System System Compensation Voltage Input Res. Input Cap. Readout Gnd. Bandwidth Risetime Range (pf.): Max. (M ) (pf.): Actuator Ref.: (3dB) MHz.: ns (Note 2) Pin: 6101A X10 150 2.33 10-30 300 10 10.5 X 6102A X10 250 1.4 10-30 300 10 10 X Model : Attention: System System Compensation Voltage Input Res. Input Cap. Readout Gnd. Bandwidth Risetime Range (pf.): Max. (M ) (pf.): Actuator Ref.: (3dB) MHz.: ns (Note 2) Pin: 5809A X10 300 1.17 10-60 300 10 17 5812A X10 300 1.17 10-60 300 10 17 X 1.) Measurements based on 1M Ohm, 20 pf. Oscilloscope. 2.) Maximum probe input voltage is limited to the lesser of 300VDC (includes AC peak to 1.3MHz.) or on X1, to the driven equipments input rating. All dimensions are in inches. Tolerances (except noted): .xx = .02 (,51 mm), .xxx = .005 (,127 mm). All specifications are to the latest revisions. Specifications are subject to change without notice. Registered trademarks are the property of their respective companies. Made in USA 6/9/99 PomonaACCESS 90474 (800) 444-6785 or (425) 446-6010 Sales: 800-490-2361 Fax: 888-403-3360 SY/EH/LS More drawings available at www.pomonaelectronics.com Technical Assistance: 800-241-2060 S: Engineering Release DataSheets FlukeDataSheet d4550B-SP150B 6 01.doc Page 2 of 6