DIN Rail Mount Datasheet CTR Series Ratings 25 A per phase 600 VAC DIN-RAIL or Panel Mount 90mm (width) package UL 508 Endurance Rating for Enhanced Reliability SCR output for heavy industrial loads Overvoltage Protection Built in (Internal TVS) LED input Status indicator AC or DC control Zero voltage or instantaneous turn-on output UL Recognized, CE, RoHS and EMC Compliant PRODUCT SELECTION Control Voltage 25 A 4-32 VDC Control CTRD6025 90-140 VAC Control CRTB6025 180-280 VAC Control CTRC6025 AVAILABLE OPTIONS Control Voltage B: 90 to 140 VAC Output Rating C: 180 to 280 VAC 25: 25 Amps/phase D: 4 to 32 VDC Series CTR D 60 25 -10 CTR: Standard 3 phase Thermal Pad Line Voltage Rating 90 mm DIN rail mount Blank: Zero Voltage 60: 48 to 600 VAC SSR package Turn-On -10: Instantaneous Turn-On Required for valid part number For options only and not required for valid part number Not all part number combinations are available. * Contact Crydom Technical Support for information on the availability of a specific part number. (1) OUTPUT SPECIFICATIONS Description CTRx6025 Operating Voltage (47-63Hz) VRMS 48-600 Transient Overvoltage Vpk 1100 Maximum Load Current Arms (2) 25 Minimum Load Current Arms 0.1 Maximum Off-State Leakage Current Rated Voltage mArms 0.25 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (3) 500 Maximum On-State Voltage Drop Rated Current Vpk 1.35 Maximum Surge Current (50/60 Hz, 1 cycle) Apk 286/300 Maximum I t for Fusing (50/60Hz, 1/2 cycle ) A sec 410/374 UL/IEC 60947 Motor Control Rating 240V HP/KW (4) 1/0.74 UL/IEC 60947 Motor Control Rating 380V HP/KW (4) 2/1.48 UL/IEC 60947 Motor Control Rating 480V HP/KW (4) 3/2.22 Minimum Power Factor (with Maximum Load) 0.5 Min/Max stranded wire 16/8 AWG Min/Max solid wire 16/10 AWG FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2020 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount Datasheet (1) INPUT SPECIFICATIONS Description CTRD6025 CTRB6025 CTRC6025 Control Voltage Range 4.0-32 VDC 90-140 Vrms 180-280 Vrms Minimum Turn-On Voltage 4.0 VDC 90 Vrms 180 Vrms Must Turn-Off Voltage 1.0 VDC 10 Vrms 10 Vrms Minimum Input Current (5) 22 mA 15 mA 19 mA Maximum Input Current (5) 28 mA 19 mA 24 mA Maximum Turn-On Time msec (6) 1/2 Cycle 20 20 Maximum Turn-Off Time msec 1/2 Cycle 30 30 Min/Max stranded/solid wire 24/16 AWG 24/16 AWG 24/16 AWG (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 9 Minimum Insulation Resistance ( 500 VDC) 10 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -20 to 80C Ambient Storage Temperature Range -40 to 100 C Status Indicator Display Green LED Weight (typical) 21.2 oz. (600g) Terminals Box Clamp Type Recommended Terminal Screw Torque Range: 5.0-6.0 in lib (0.6-0.7 Nm) Min. Side bye Side Spacing 0.8 inch (20mm) (1) MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches millimeters 3.54 90.0 4.86 3.26 123.4 82.8 3.59 3.82 3.47 91.2 97.0 88.1 0.18 4.5 3.26 82.8 GENERAL NOTES (1) All parameters at 25C unless otherwise specied. (2) See Derating Curves. (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (4) At 40C Ambient temperature. (5) Turn-on time for DC control Instantaneous turn-on versions is 0.05 msec. (6) Input circuitry incorporates active current limiter. (7) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60C. For additional information or specic questions, contact Crydom Technical Support. Do not forget to visit us at: www.crydom.com Copyright 2020 Crydom Inc. Specifications subject to change without notice.