DIN Rail Mount DataSheet AC DC SeriesOne DR Series ATEX Ratings 3 Amps Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output UL 508 Endurance Rating for Enhanced Reliability UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280V, 3 A 600V, 3 A 60V, 3 A 100V, 3 A 4-32 VDC DR24D03X DR48D03X DR06D03X DR10D03X 90-140 VAC DR24B03X 200-280 VAC DR24A03X 18-36 VAC DR24E03X AVAILABLE OPTIONS Operating Voltage Switching Type Blank: Zero Voltage Turn-On 06: 1-60 VDC 10: 1-100 VDC (AC Output Only) Rated Load Current R: Instantaneous Turn-On 24: 24-280 VAC (AC Output) Series 48: 48-600 VAC 03: 3 Amps X R DR 06 D 03 Control Voltage Agency Approvals D: 4-32 VDC X: ATEX II 3G Ex nA IIC T4 Gc A: 200-265 VAC approved AC B: 90-140 VAC Output E: 18-36 VAC (1) Only Required for valid part number For options only and not required for valid part number (2) OUTPUT SPECIFICATIONS AC Output Description DR24x03X DR48x03X DR06D03X DR10D03X Operating Voltage (3) 24-280 Vrms 48-600 Vrms 1-60 VDC 1-100 VDC Transient Overvoltage Vpk 600 1200 N/A N/A Maximum Load Current, resistive (4) 3 Arms 3 Arms 3 3 Minimum Load Current 150 mArms 150 mArms 2.5 mAdc 2.5 mAdc Maximum Off-State Leakage Current Rated Voltage mA 0.1 0.1 0.1 0.1 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (5) 500 500 N/A N/A Maximum On-State Voltage Drop Rated Current Vpk 1.3 1.3 0.6 0.6 Maximum Surge Current (50/60Hz, 1 cycle) Apk 285/300 285/300 60 60 Maximum It for Fusing (50/60 Hz, 1/2 cycle) A sec 410/375 410/375 N/A N/A HP Rating UL 508/IEC60947 HP (KW) 240V 1/4 (.18) 1/4 (.18) N/A N/A HP Rating UL 508/IEC60947 HP (KW) 380V N/A 1/3 (.25) N/A N/A HP Rating UL 508/IEC60947 HP (KW) 480V N/A 1/2 (.37) N/A N/A Minimum Power Factor (at Maximum Load) 0.5 0.5 N/A N/A Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Weight (Typical) 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount DataSheet (2) INPUT SPECIFICATIONS Description DRxxDxxX DRxxBxxX DRxxAxxX DRxxExxX Control Voltage Range (6) 4-32 VDC 90-140 Vrms 200-265 Vrms 18-36 Vrms (1) Minimum Turn-On Voltage 4.0 VDC 90 Vrms 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 40 Vrms 4 Vrms 10 Vrms Minimum Input Current for mA (7) 9 3 2.5 3.5 Maximum Input Current for mA (7) 11 5 3.3 8 Maximum Turn-on Time msec (8) (9) 1/2 Cycle 20 msec 20 msec 20 msec 1/2 Cycle 30 msec 30 msec Maximum Turn-off Time msec (10) 30 msec Min/Max stranded/solid wire 22/16 AWG 22/16 AWG 22/16 AWG 22/16 AWG (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms (11) 9 10 Ohm Minimum Insulation Resistance ( 500 VDC) Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -20 to 40 C Ambient Storage Temperature Range -30 to 100 C Recommended Terminal Screw Torque Range 4.4-7.0 in-lb (0.5-0.8Nm) GENERAL NOTES (1) E option is UL certied for AC control voltage, but it works also with 18-36 VDC input range. (2) All parameters at 25C unless otherwise specied. (3) For AC output frequency is 47-63Hz (4) See Derating curves (5) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (6) DC control includes reverse polarity protection. (7) Input circuitry incorporates active current limiter. (8) Turn-on time for DC control random turn-on versions is 0.1 msec. (9) Turn-on time for DC output 600sec. (10) Turn-off time for DC output 300sec. (11) 2500 Vrms for DC output. Standards of Compliance IEC 62314 LC A, Resistive or Slightly Inductive Load Ratings: 3 A 40C ambient for DR24x03X, 3 A 40C ambient for DR48x03X LC B, Motor Loads Ratings: 0.18KW 240VAC for DR24x03X and 0.375KW 480 VAC DR48x13X Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classied) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for class I, Division 2 ATEX Compliance with Essential Health and Safety Requirements has been assessed by reference to Standards EN 60079-0:2012+A11:2013 and EN 60079-15-:2010 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.