DIN Rail Mount DataSheet DRC Series with EMR Auxiliary Contacts Start / Stop Reversing 7.6 Amp AC Semiconductor Motor Controller Load voltage range up to 600 VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) See DRC Series models with Solid State Auxiliary Contacts Solicon DRC Series with EMR Auxiliary Contacts are Solid State instantaneously upon application of the control voltage unless an Contactors intended for frequently switching on and off three instantaneous change of direction is commanded, then it will phase loads up to 5 HP, 600 VAC 7.6 Amps. They are available in delay the direction change by 100msec in order to prevent both contactor versions DRC3P and reversing contactor versions simultaneous forward and reverse operations. DRC3R. All the models of Solicon DRC Series with EMR Auxiliary Contacts The Solicon Contactor DRC3P is available in either instantaneous combine the benefits and advantages of a solid state contactor turn-on (for Motor Control) or zero voltage turn-on (for Resistive with the functionality and simplicity of use of an Loads). It is available in either 2 or 3 controlled leg versions. The electromechanical contactor thanks to the proprietary thermal 2 legs control version is particularly suitable for motor control management technology (Patented) and complete electrical circuits where the neutral conductor is not utilized. insulation (no grounding required) the embedded EMR auxiliary contacts, normally open and/or normally closed, are intended to The Solicon Reversing Contactor DRC3R includes an interlock be used at 110VDC/140VAC. All models include overvoltage control that allows only off, forward and reverse operation in a protection. safe mode while providing high space saving it switches PRODUCT SELECTION Control Voltage 1 NO + 1NC Auxiliary Contact 2 NO Auxiliary Contact 24 VAC/DC DRC3P48D433, DRC3P60D433 DRC3P48D440, DRC3P60D440 24 VDC DRC3R40E440, DRC3R48E440 AVAILABLE OPTIONS Operating Voltage Load Current per Phase 40: 400 VAC 4: 7.6 Amp FLA (3R function only) (x2 Controlled Legs Switching Mode 48: 480 VAC & 3R function) (3P function only) 60: 600 VAC 4.8 Amp FLA Blank: Zero Voltage Turn-On (3P function only) Series (x3 Controlled Legs only) R: Instantaneous Turn-On DRC 3P 48 D 4 33 R 2 Function Control Voltage Auxiliary Contacts, Controlled Legs 3P: Contactor D: 18-30 VAC/DC N.O. - N.C. (3P function only) 3R: Reversing Contactor (3P function only) 33: 1 Normally Open EMR Blank: 3 Controlled Legs E: 18-30 VDC 1 Normally Closed EMR 2: 2 Controlled Legs (3R function only) (3P function only) 40: 2 Normally Open EMR Required for valid part number For options only and not required for valid part number FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount DataSheet (1) OUTPUT SPECIFICATIONS Description DRC3P48D4x DRC3P48D4x2 DRC3P60D4x DRC3P60D4x2 DRC3R40E440 DRC3R48E440 Operating Voltage (47-63Hz) VRMS 48-530 48-530 48-600 48-600 48-415 48-510 Transient Overvoltage Vpk (2)(3) 1200 1200 1200 1600 1200 1200 Maximum Off-State Leakage Current Rated Voltage mARMS 3.0 3.0 1.0 1.0 5.5 5.5 Maximum Off-State dv/dt Maximum Rated Voltage V/sec 500 500 500 500 500 500 Load Current, General Use UL508 /AC51 40C ARMS (4) 5 7.6 5 7.6 7.6 7.6 Load Current, Motor Controller UL508 /AC-53a 480VAC ARMS (4) 4.8 7.6 4.8 7.6 7.6 7.6 Minimum Load Current ARMS 0.15 0.15 0.15 0.15 0.15 0.15 Maximum Surge Current Apk 1 Cycle 60Hz 750 750 750 750 750 625 Maximum Surge Current Apk 1 Cycle 50Hz 716 716 716 716 716 597 2 2 Maximum I t for Fusing (8.33msec) A sec 2330 2330 2330 2330 2330 1621 2 2 Maximum I t for Fusing (10msec) A sec 2560 2560 2560 2560 2560 1779 Maximum On-State Voltage Drop Rated Current VRMS 1.15 per channel 1.15 per channel 1.15 per channel 1.15 per channel 1.3 per channel 1.3 per channel Minimum Power Factor (with Maximum Load) 0.5 0.5 0.7 0.7 0.5 0.5 Ratings according to UL 508/IEC60947-4-2 HP/kW : 240 VAC 1/.75 2/1.5 1/.75 2/1.5 2/1.5 2/1.5 Ratings according to UL 508/IEC60947-4-2 HP/kW : 400 VAC 2/1.5 3/2.2 2/1.5 3/2.2 3/2.2 3/2.2 Ratings according to UL 508/IEC60947-4-2 HP/kW : 480 VAC 3/2.2 5/3.7 3/2.2 5/3.7 - 5/3.7 Motor Ratings 600 VAC HP/kW - - 3/2.2 5/3.7 - - (1) INPUT SPECIFICATIONS Description Option D Option E Control Voltage Range 18-30 VAC / VDC 18-30 VDC Minimum Turn-On Voltage (5) 18 VAC / VDC 18 VDC Must Turn-Off Voltage 4 VAC / VDC 4 VDC Minimum Input Current (for on-state) mA 12.5 12.5 Maximum Input Current mA 32 32 Nominal Input Impedance Ohms Current Regulated Current Regulated Maximum Delay to Turn-On msec (6) 20 100 30 Maximum Turn-Off Time msec (7) 30 20 (1) AUXILIARY CONTACTS Description Normally Open Sufx 40 3P Normally Closed / Normally Open Sufx 33 Normally Open Sufx 40 3R Maximum Operating Voltage 110VDC/ 140VAC 110VDC/ 250VAC 110VDC/ 140VAC Transient Overvoltage Vpk 250 250 250 Maximum Load Current Adc/Arms (8) 0.5/0.35 0.3/0.25 0.5/0.35 Maximum Contact Rating W (8) 10/7 33/62.5 10/7 Minimum Load Current mA 10 10 10 Maximum Delay to Turn-On msec 20 20 10030 Maximum Turn-Off Time msec 30 30 20 Maximum Delay to Turn-On msec 20 20 10030 8 8 8 Mechanical Life Expectancy Ops. 10 10 10 5 5 5 Electrical Life Expectancy Ops. 10 10 10 (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) (9) 3750 Vrms 9 Minimum Insulation Resistance ( 500 VDC) 10 Ohms Maximum Capacitance, Input/Output 20 pF Ambient Operating Temperature Range (10) -20 to 60 C Ambient Storage Temperature Range -30 to 85 C Weight (typical) 2 Controlled Legs (6.9 oz 197 g ) / 3 Controlled Legs (8.0 oz 228 g ) Housing Material UL94 V-0 Housing Color Black and Light Gray LED Status Indicator (color) (11) Forward (Green) / Reverse (Amber) Short Circuit Current Rating (12) 100kA Pollution Degree 2 Protection Degree (13) IP20 Humidity 85% non-condensing Control and Auxiliary Contact Terminal Screw Torque Range (lb-in/Nm) 12 / 1.36 Load Terminal Screw Torque Range (lb-in/Nm) 15 / 1.7 2 Input Terminal Wire Capacity 18-12 AWG (IEC 1-4 mm ) (stranded /solid) 2 Output Terminal Wire Capacity 18-10 AWG (IEC 1-6 mm ) (stranded /solid) Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.