DIN Rail Mount Datasheet GNR 22.5mm Series Current ratings of 10, 20 and 30 amps Output voltage ratings: 24-280 and 48-600 VAC Direct Bond Copper (DBC) Substrate LED input status indicator UL 508 Endurance Rating for Enhanced Reliability UL/CSA Approved, CE Compliant Built-in overvoltage protection DIN Rail or Panel Mount Zero voltage or Instantaneous turn-on output PRODUCT SELECTION Control Voltage 10A 20A 30A 4-32 VDC GNR10DHZ GNR20DHZ GNR30DHZ 90-140 VAC GNR10BHZ GNR20BHZ GNR30BHZ 180-280 VAC GNR10AHZ GNR20AHZ GNR30AHZ AVAILABLE OPTIONS Operating Voltage Switching Type A: 180-260 VAC R: Instantaneous Turn-on B: 90-140 VAC (for DC control only) Series D: 4-32 VDC Z: Zero voltage Turn-on GNR 10 A H Z Terminal Layout Rated Load Current C: Contactor configuration 10: 10 Amps H: Relay configuration 20: 20 Amps 30: 30 Amps Required for valid part number For options only and not required for valid part number (1) OUTPUT SPECIFICATIONS Description GNR10 GNR20 GNR30 Operating Voltage (47-440Hz) Vrms 24-280 48-600 48-600 Transient Overvoltage Vpk, t=1 min. 600 1100 1100 Maximum Off-State Leakage Current Rated Voltage mArms 0.1 0.1 0.1 500 500 500 Static Off-State dv/dt ( V/sec, Ta=25C) (2) Maximum Load Current Arms 10 20 30 100 100 100 Minimum Load Current mArms 190/200 286/300 716/750 Maximum Surge Current (50/60 Hz, 1 cycle) Apk 65 85 150 1 Second Surge Current (Apk Ta=25C) 50/60 Hz 1.5 1.35 1.35 Forward Voltage Drop (Vpk max, Ta=25C) 182/166 410/374 2562/2334 Maximum I t for Fusing (50/60Hz, 1/2 cycle ) A sec - 1.2/9.8 3/4 / 13.8 HP Ratings at 120V / FLC Arms - 1/8 2/12 HP Ratings at 240V / FLC Arms 16/8 AWG 16/8 AWG 16/8 AWG Min/Max stranded wire 16/10 AWG 16/10 AWG 16/10 AWG Min/Max solid wire FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2018 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount Datasheet (1) INPUT SPECIFICATIONS Description GNRxxDx GNRxxBx GNRxxAx Control Voltage Range (3) 4.0-32 VDC 90-140 Vrms 180-280 Vrms Minimum Turn-On Voltage 4.0 VDC 90 Vrms 180 Vrms Must Turn-Off Voltage 1.0 VDC 10 Vrms 10 Vrms Minimum Input Current (for on-state) 6 mA 5 mArms 6 mA Maximum Input Current 10 mA 23 mArms 2 mA Input Resistance Current Regulated Current Regulated Current Regulated Maximum Turn-Off Time msec 1/2 Cycle 20 20 Maximum Turn-On Time msec (4) 1/2 Cycle 30 30 Min/Max stranded/solid wire 24/16 AWG 24/16 AWG 24/16 AWG (1) GENERAL SPECIFICATIONS Description Parameters Ambient Operating Temperature Range (3) -20 to 80C Ambient Storage Temperature Range -40 to 100 C 4000 Vrms Dielectric Strength, Input to Output (50/60Hz) Dielectric Strength, Input/Output to Ground (50/60Hz) 2500 Vrms Maximum Capacitance, Input/Output 8 pF Housing Material UL 94V0 (self extinguishing) Input Status Indicator Green LED Weight (typical) 7.94 oz (225g) GENERAL NOTES (1) All parameters at 25C unless otherwise specied. (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60C. (4) Turn-on time for Instantaneous version (R sufx) is 0.1 msec (for DC control only). For additional information or specic questions, contact Crydom Technical Support. (1) MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches millimeters Contactor Configuration 0.87 22.5 0.68 4.75 17.3 120.8 0.21 0.18 5.3 4.5 DIA. 3.47 3.54 3.85 88.2 3.54 89.8 97.8 89.8 0.21 5.3 DIA. 0.19 0.18 4.6 4.8 0.70 17.8 Do not forget to visit us at: www.crydom.com Copyright 2018 Crydom Inc. Specifications subject to change without notice.