Panel Mount Datasheet HA / HD60 Series Ratings from 25A to 125A 48-660 VAC AC or DC control SCR output for heavy industrial loads Direct bond copper substrate Zero Voltage or instantaneous turn-on outputs EMC compliant to Level 3 UL/CSA/VDE Approved, CE Compliant to EN60950-1 Direct power lead frame Improved SEMS screw and washer Epoxy free design Redesigned housing with anti-rotation barriers For Generation 3 datasheet click here PRODUCT SELECTION Control Voltage 25A 50A 90A 125A 4-32 VDC HD6025 HD6050 HD6090 HD60125 90-280 Vrms HA6025 HA6050 HA6090 HA60125 18-36 Vrms HA6025E HA6050E HA6090E HA60125E AVAILABLE OPTIONS Control Voltage A: 90-280 VAC Overvoltage Protection Thermal Pad D: 4-32 VDC Blank: Not Included Blank: Not Included Series AxxxxE: 18-36 VAC P: Included (3) H: Included H A 60 25 E K P G H -10 Switching Type Operating Rated Load Current Termination Input Status LED Voltage 25: 25 Amps Blank: Screw Blank: Not Included Blank: Zero Voltage Turn-On 60: 48-660 VAC 50: 50 Amps F: Quick Connect G: Included -10: Instantaneous Turn-On(4) (1) 90: 90 Amps (Up to 50 Amps models) 125: 125 Amps K: Hex standoffs (2) Required for valid part number For options only and not required for valid part number * Not all part number combinations are available. Contact Crydom Technical Support for informacion on the availability of a specific part number. (5) OUTPUT SPECIFICATIONS Descrption 25A 50A 90A 125A Operating Voltage (47-440Hz) Vrms 48-660 48-660 48-660 48-660 Transient Overvoltage Vpk 1200 1200 1200 1200 Maximum Off-State Leakage Current Rated Voltage mArms 1.0 1.0 1.0 1.0 Minimum Off-State dv/dt Maximum Rated Voltage V/sec 500 500 500 500 Maximum Load Current Arms (2)(6) 25 50 90 125 Minimum Load Current mArms 150 150 150 150 Maximum 1 Cycle Surge Current (50/60Hz) Apk 235/250 597/625 1145/1200 1670/1750 Maximum On-State Voltage Drop Rated Current Vrms 1.15 1.15 1.15 1.15 Thermal Resistance Junction to Case (Rjc) C/W 0.8 0.45 0.27 0.22 Maximum 1/2 Cycle I t for Fusing (50/60Hz) A sec 285/259 1770/1629 6560/5976 13950/12709 Minimum Power Factor ( at Maximum Load) (3) 0.5 0.5 0.5 0.5 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.Panel Mount Datasheet (5) INPUT SPECIFICATIONS Description HD60xx HA60xx HA60xxE Control Voltage Range 4-32 VDC 90-280 Vrms 18-36 Vrms Minimum Turn-On Voltage 4.0 VDC (7) 90 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 10 Vrms 4.0 Vrms Maximum Reverse Voltage -32 VDC - - Minimum Input Current 7.0 mA 5 mA 16 mA Maximum Input Current 12 mA 10 mA 20 mA Nominal Input Impedance Current Regulated (8) Maximum Turn-On Time msec 1/2 Cycle 20 20 Maximum Turn-Off Time msec 1/2 Cycle 30 30 (5) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 9 Minimum Insulation Resistance ( 500 VDC) 10 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 C Ambient Storage Temperature Range -40 to 125 C Weight (typical) 2.6 oz (74.9 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 Input/Load terminal Screw Torque Range (in-lb/Nm) (2) w/K option 8-10 / 0.9-1.13 Input/Output Terminal Screw Thread Size 6-32 UNC / 8-32 UNC Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator w/G option (green) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 40C ambient temperature (9) 7,210,376 hours (823 years) MTBF (Mean Time Between Failures) at 60C ambient temperature (9) WIRING DIAGRAM AC Input Current vs Input Voltage Recommended Wire Sizes V Standard Regulated DC Input Wire Size Wire Pull-Out 25 Terminals (Solid / Stranded) Strength (lb) N (10) Load 20 2 24 AWG (0.2 mm ) / 0.2 minimum 10 44.5 Input 1 ( ) 2 ( ) 15 2 2 x 12 AWG (3.3 mm ) / 3.3 maximum 90 400 2 10 20 AWG (0.5 mm ) / 0.518 minimum 30 133 2 Output 2 2 x 10 AWG (5.3 mm ) / 5.3 110 490 5 1 OUTPUT S OL I D S T A T E R EL A Y 2 2 x 8 AWG (8.4 mm ) / 8.4 maximum 90 400 0 0 5 10 15 20 25 30 4 INPUT 3 DC Input Voltage 4 ( / ) 3 (+ / ) EQUIVALENT CIRCUIT BLOCK DIAGRAMS Diagram: HD60xx Diagram: HAxxxx 4 1 4 1 -DC AC AC AC Current Limiter (11) Trigger AC/DC (12) Trigger (12) Converter Circuit Circuit (11) +DC 3 2 AC AC 3 2 AC Current Limiter Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice. Input Current (mA)