HS122DR Series Assemblies 45 amp AC output 40C Single or Dual Channel output 3 to 32 VDC input control voltage DIN Rail mounted uL, CSA, VDE, CE approved SSRs PRODUCT SELECTION Description 45 A 45 A 45 A 3-32 VDC Control HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U OUTPUT SPECIFICATIONS (1) Description HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U Operating Voltage (47-63Hz) Vrms 24-280 48-660 24-280 Transient Overvoltage Vpk 600 1200 600 Maximum Off-State Leakage Current Rated Voltage mArms 10 10 0.1 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (2) 500 500 500 Maximum Load Current Arms 45 45 45 Minimum Load Current Arms 0.04 0.04 0.15 Maximum Surge Current (16.6ms) Apk 625 625 750 Maximum On-State Voltage Drop Rated Current Vpk 1.6 1.7 1.3 Maximum It for Fusing (8.3 msec) A sec 1620 1620 2320 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 INPUT SPECIFICATIONS (1) Description HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U Control Voltage Range 3-32 VDC 3-32 VDC 4-32 VDC Minimum Turn-On Voltage 3.0 VDC 3.0 VDC 4.0 VDC Minimum Turn-Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC Maximum Reverse Voltage 32 VDC 32 VDC 32 VDC Typical Input Current 3.4 mA 5 VDC 2.0 mA (3) 10 mA 12 VDC Nominal Input Impeadance 1500 Ohms (3) (3) Maximum Turn-On Time msec 1/2 Cycle 1/2 Cycle 1/2 Cycle Maximum Turn-Off Time msec 1/2 Cycle 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS Description HS122DR-Dxx50 HS122DR-CC2450W3U Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 4000 Vrms 9 9 Minimum Insulation Resistance ( 500 V DC) 10 Ohms 10 Ohms Maximum Capacitance, Input/Output 8 pF 10 pF Ambient Operating Temperature Range -40 to 80C -40 to 80C Ambient Storage Temperature Range -40 to 125C -40 to 125C Status Indicator Display None Yes Weight (typical) 1.43 lb. (649g) 1.49 lb (662g) Encapsulation Themally Conductive Epoxy Themally Conductive Epoxy Recommended Terminal Screw Torque Range: 6-32 Screws - 10 in/lbs. 8-32 Screws - 20 in/lbs. 8-32 Screws - 20 in/lbs. (Screws dry without (Screws dry without grease) grease) Thermal pad installed Yes Yes GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3) Input circuitry for DC control version incorporates active current limiter (HD and Dual model only) MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 Agency approvals are for relay only. E116949 (D2450) E116950 (HD6050, CC2450W3U) LR81689 (D2450, HD6050) 10143 UG (D2450, HD6050) Rev. 110811