PM67 SERIES PANEL MOUNT SOLID STATE RELAYS Introduction The PM67 is a compact 3-phase solid state relay in a panel mountable 67.5mm wide package with output ratings up to 75 Amps per channel 40C. Its built-in overvoltage protection and the optional overtemperature protection make it suitable for demanding heating, motion and lighting applications. Its easy to install and its large cage clamp terminals allow connecting wires up to 2 AWG size on the output terminals without the use of any additional accessories, therefore reducing installation cost and time. UL approved and VDE certified, the PM67 is a powerful and versatile solid state relay with superior performance when compared to previous generations and competitor products. Features 3-Phase AC Output Panel Mount SSRs Output ratings up to 75 Amps at 600 VAC 2 & 3 controlled Legs option Over Temperature protection w/alarm (optional) Built-in overvoltage protection Clamp Cage terminal type accepts up to 2 AWG wire size. Layout of mounting holes compatible with standard hockey puck SSRs IP20 touch-safe housing AC or DC control cURus and VDE approved Applications Plastic injection molding equipment Packaging equipment Industrial ovens Lighting control Professional cooking equipment Pump control Conveyor drives HVAC&R PRODUCT SELECTION 25A 30A 50A 55A 60A 75A Control Voltage 4-32 VDC PM6760D25P PM6760D30P PM6760D50P PM6760D55P PM6760D60P PM6760D75P 90-280 VAC/VDC PM6760A25P PM6760A30P PM6760A50P PM6760A55P PM6760A60P PM6760A75P Page 1 www.sensata.com Copyright 2019 Sensata Technologies, Inc.Example : PM6760A25RPTA ORDERING OPTIONS Description of part number example PM67 60 x xx x P xx Family Operating Voltage 60 = 48-600 VAC Control Voltage D = 4-32 VDC (4-28 VDC for TA option) A = 90-280 VAC/VDC Rated Load Current 25 = 25A, 3-legs 55 = 55A, 2-legs 30 = 30A, 2-legs 60 = 60A, 3-legs 50 = 50A, 3-legs 75 = 75A, 2-legs Switching Type Blank = Zero voltage turn on R = Instantaneous turn on Overvoltage Protection P = With internal overvoltage protection (1) Over Temperature Protection Required for valid part number Blank = No Over Temperature protection TA = With Over Temperature Protection and Alarm Output For options only and not required for valid part number SPECIFICATIONS (2) Output Description 25A 30A 50A 55A 60A 75A 48-600 48-600 48-600 48-600 48-600 48-600 Operating Voltage (47-440Hz) V RMS (3) 1200 1200 1200 1200 1200 1200 Transient Overvoltage Vpk 1 1 1 1 1 1 Maximum Off-State Leakage Current Rated Voltage mA RMS 500 500 500 500 500 500 Minimum Off-State dV/dt Maximum Rated Voltage V/ sec 25 30 50 55 60 75 Load Current, General Use UL508/LC A IEC62314 40C A RMS 6.4/3.9 6.4/3.9 12/6.8 12/6.8 21/17.6 21/17.6 Load Current, Motor Starting UL508 FLA/LC B IEC62314 40C A RMS 100 100 100 100 150 150 Minimum Load Current mA RMS 286/300 286/300 716/750 716/750 1290/1350 1290/1350 Maximum 1 Cycle Surge Current (50/60Hz) Apk 1.25 1.3 1.25 1.3 1.15 1.20 Maximum On-State Voltage Drop Rated Current V RMS 409/375 409/375 2563/2343 2563/2343 8320/7593 8320/7593 Maximum 1/2 Cycle I t for Fusing (50/60Hz) A sec 0.5 0.5 0.5 0.5 0.5 0.5 Minimum Power Factor (at Maximum Load) 0.5/1.0/3.0 0.75/1.0/3.0 1.5/3.0/7.5 1.5/3.0/7.5 3.0/5.0/15.0 3.0/5.0/15.0 Motor Rating UL 508: 120 VAC / 240 VAC / 480 VAC HP 0.75/1.5/2.2 0.75/1.5/2.2 1.5/3.0/4.0 1.5/3.0/4.0 4.0/7.5/11.0 4.0/7.5/11.0 Motor Rating IEC62314: 240 VAC / 400 VAC / 500 VAC kW Page 2 www.sensata.com Copyright 2019 Sensata Technologies, Inc.