PTA5000 Hermetically Sealed Modular Pressure Sensor Typical Applications Compressors Hydraulic Systems Agricultural Equipment Description Construction Equipment TThe PTA5000 utilizes Kavlicos thin lm strain Heat Pumps gauge sensing technology, incorporating a Wind Energy hermetically sealed design with no internal HVAC Systems sealing required. Designed for harsh Chemical Industry environments, a rugged 304 stainless steel housing surrounds the PTA5000 transducer. Standard Full Scale Pressure Ranges The PTA5000s small, compact design as well 0-100, 0-150, 0-200, 0-300, 0-600, as low overall weight is ideal for applications with 0-1000, 0-2000, 0-3000, 0-6000, 0-9000 spacing and weight limitations. This easy-to-use and 0-10000 Psi (Gage) sensor is media resistant, allowing for a broad range of liquid and gaseous media compatibility. Features It can be used at high operating temperatures and has internal temperature compensation. Hermetically Sealed Highly reliable, the PTA5000 provides accurate, Rugged & Durable high pressure measurements every time. Compact & Light-weight Resistant to Chemical Attack Speci cally designed for industrial applications, Superior Long-Term Stability & Repeatability the PTA5000 can be customized to t your application-speci c needs. So contact us to Outstanding Shock & Vibration Performance place your custom order now. Potsdamer Str. 14, 32423 Minden, Germany 235 E. Main St., Suite 102A, Northville, MI 48167, USA Tel: +49 571 3859-0 - Fax: +49 571 3859-119 Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810 Email: info kavlico.de Email: pressure.sensors kavlico.com www.kavlico.comTechnical Speci cations Pressure ranges from 0 to psi (gage) 100 150 200 300 600 1000 2000 3000 6000 9000 10000 psi (gage) 290 290 465 725 1160 1740 4640 5540 8700 13050 13050 Proof pressure Burst pressure psi (gage) 435 435 695 1085 1740 2610 6960 7250 11600 17400 17400 Individual customized calibration on request. Electrical Output Signal 4 - 20 mA 0.5 - 4.5 VDC ratiometric 0 - 10 VDC Operating supply voltage 8 - 30 VDC 5 VDC 5 % 14 - 30 VDC Power consumption Vsup 8 VDC Load 4.7 k 4.7 k 0,02 A Overvoltage protection min. 33 VDC min. 6 VDC min. 33 VDC Short-circuit proofness not applicable Yes *) Yes *) Reverse polarity protection Yes *) Yes *) Yes *) *) for min. 3 intervals at 5 minutes each at max. rated supply voltage *) for min. 10 seconds on assigned pins at max. rated supply voltage Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance to UL/EN/IEC 60950-1 or class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in this enviroment. For indoor and outdoor use, not exposed to direct sunlight. Pin assignment Current Output Voltage Output Connector PIN 1 / A PIN 2 / B PIN 3 / C PIN 4 PIN 1 / A PIN 2 / B PIN 3 / C PIN 4 M12 4-pole Vsup Iout Vsup Vout GND Packard Metri-Pack 150 Iout Vsup GND Vsup Vout Response time Accuracy Reference conditions to EN 61298-1 Accuracy *) Non-linearity **) 0.2 % of span Non-repeatability 0.1 % of span 1-year stability 0.2 % of span *) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down **) BFSL according to IEC 61298-2 Temperatures Medium -30 C to +120 C Environmental -30 C to +100 C (depending on electrical connector) Storage -30 C to +100 C (depending on electrical connector) Temperature coefficients TC zero 0.2 % of span / 10 K within temperature range 0 C to +80 C TC span 0.2 % of span / 10 K within temperature range 0 C to +80 C Conformity UL Standard(s) for Safety: Electrical Equipment for Measurement, Control and Laboratory Use - UL 61010-1 RoHS According to 2002/95/EC RoHS Directive Pressure equipment directive 97/23/EC CE EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B) and Immunity (industrial locations) Vibration resistance IEC 60068-2-64 (RANDOM) 20 PSD Shock resistance 25 g minimum according to EN 60068-2-27 Packard Electrical connector M12 - 4 pole Metri-Pack 150 - 3 pole Ingress protection IP67 / IP69K (with special mating connector) IP67 per IEC 60 529 Weight appr. 50 gram (sensor without mating connector) Media All class II fluids and gases compatible with stainless steel 304 (1.4301) Customized versions on request - contact factory for details. Potsdamer Str. 14, 32423 Minden, Germany 235 E. Main St., Suite 102A, Northville, MI 48167, USA Tel: +49 571 3859-0 - Fax: +49 571 3859-119 Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810 Email: info kavlico.de Email: pressure.sensors kavlico.com www.kavlico.com t t t