Technical Information Ultrasonic Cleaner for PCBs (R3132) Health and Safety Data SAFETY DATA SHEET PRODUCT PRODUCT NAME: Ultrasonic cleaner for PCBs IDENTIFICATION PRODUCT CODE: UT/FLU01 PRODUCT TYPE: CLEANER AND DEGREASER SUPPLIER: Shesto Limited 3 Century Court, Tolpits Lane, Watford Hertfordshire, WD18 9RS Tel: +44 (0)208 451 6188 DATE ISSUED: 21-06-1118-08-15 COMPOSITION/ INGREDIENTS CAS NO. WT% HEALTH RISK INFORMATION sodium metasilicate 6834-92-0 1-10 Xi 36/38 ON INGREDIENTS non ionic surfactants 66455-14-9 1-10 Xn Ethylene glycol butyl ether 111-76-2 20-59 Xn 20/21/22,37 Dipropylene glycol methyl ether 34590-94-8 1-10 Xn 20/21/22,37 HAZARDS HUMAN HEALTH IDENTIFICATION HAZARDS: Harmful by inhalation, in contact with skin and if swallowed. Irritating to eyes and skin FIRST AID EYES: Immediately flood the eye with plenty of water for at least 15 minutes, holding the eye MEASURES open. Obtain medical attention immediately INGESTION: Wash out mouth with water. Have victim drink 240-300ml of water to dilute stomach contents. Obtain medical attention. Do not induce vomiting. SKIN: Immediately wash skin thoroughly with soap and water. Remove contaminated clothing as washing proceeds. Contaminated clothing should be washed or dry- cleaned before re-use. Obtain medical attention if blistering occurs or redness persists. INHALATION: Remove from exposure. Keep warm and at rest. If there is difficulty in breathing, give oxygen. If breathing stops or shows signs of failing, give artificial respiration. Do not use mouth to mouth ventilation. Obtain medical attention urgently. FIRE FIGHTING EXTINGUISHER: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. Select MEASURES extinguishing agent appropriate to other materials involved. Keep containers and surroundings cool with water spray. HAZARDS: Hazardous Combustion Products : CARBON OXIDES PROTECTIVE EQUIPMENT: As for personal protection. ACCIDENTAL SPILLAGE CLEANUP: Wash away to drain with plenty of water. Contain and absorb with sand RELEASE or earth. MEASURES PERSONAL PRECAUTIONS: As for exposure controls - personal protection. ENVIRONMENTAL: For large spillages collect for disposal. Inform local authorities for advice. HANDLING HANDLING: As for exposure controls - personal protection. AND STORAGE STORAGE: Store in original containers under dry conditions. Avoid extremes of temperature. EXPOSURE EXPOSURE CONTROL: OES-LTEL = not listed, OES - STEL = 2mg.m-3 CONTROLS/ RESPIRATORY: No special requirements. Good ventilation is normally sufficient. PERSONAL SKIN: Rubber or PVC gloves. PROTECTION EYES: Eye goggles or a face shield. Images & Content 2015 Shesto Limited. - E&OE - Specifications subject to change without prior notice 1 OF 2 1 OF 2 1 OF 2 www.shesto.co.uk +44 (0)208 451 6188 Flux Removing SolutionTechnical Information Ultrasonic Cleaner for PCBs (R3132) PHYSICAL & APPEARANCE: Clear liquid CHEMICAL ODOUR: characteristic - etheral PROPERTIES pH: 10-11 BOILING POINT (C): 100 MELTING POINT (C): N/A EXPLOSIVE PROPERTIES: N/A AUTO IGNITION TEMP: N/A FLASH POINT (C): N/A SPECIFIC GRAVITY : 1.01 VISCOSITY (cP,c): 1 - 10 SOLUBILITY IN WATER: completely soluble STABILITY AND: STABILITY: stable REACTIVITY MATERIALS TO AVOID: combustible materials, oxidising agents and bases.. CONDITIONS TO AVOID: Keep away from heat sources, HAZARDOUS DECOMPOSITION PRODUCTS: TOXICOLOGICAL EYES: Irritant. INFORMATION SKIN: Irritant. INGESTION: Concentrate may cause burning of the throat and possible damage to internal organs. INHALATION: Harmful by inhalation OTHER Health problems are greatly reduced when product is diluted and used as directed. ECOLOGICAL MOBILITY: Mobile INFORMATION DEGRADABILITY: All surfactants are readily degradable. BIO-ACCUMULATION: No evidence of bio-accumulation or tainting of seafood (4) AQUATIC TOXICITY: LC50 96 hr 100-1000mg/L (4) (pure sodium metasilicate) DISPOSAL MATERIALS: Contain and absorb with sand or earth. PACKAGING: Can be recycled after thorough rinsing. OTHER: Incineration is the recommended method of disposal. Dispose of in accordance with all applicable local and national regulations. TRANSPORT UN NO: INFORMATION ADR/RID HAZCHEM CODE: Non hazardous for transport IMDG CLASS IMDG PAGE REGULATORY CLASSIFICATION: Irritant. INFORMATION RISK PHRASES: R20/21/22- Harmful by inhalation, in contact with skin and if swallowed. R36/38 Irritating to eyes and skin. SAFETY PHRASES: S2 keep out of reach of children. S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S28 After contact with skin, wash immediately with plenty of water. S36/37/39 Wear suitable protective clothing, gloves and eye face protection. OTHER INFO: Solutions should be used with deionised, demineralised or distilled water as OTHER Calcium carbonate and other impurities in tap water can effect/reduce the INFORMATION Read the label before opening the container. cleaning properties of the solutions and produce undesirable side effects such as deposits Images & Content 2015 Shesto Limited. - E&OE - Specifications subject to change without prior notice 2 OF 2 2 OF 2 2 OF 2 www.shesto.co.uk +44 (0)208 451 6188 Flux Removing Solution