LV1 09 Gesamt EN.book Seite 69 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 3RH, 3TH Contactor Relays 3RH1 contactor relays, 4- and 8-pole Overview The SIRIUS generation of controls is a complete, modular sys- AC and DC operation tem family, logically designed right down to the last detail, from IEC 60947, EN 60947 (VDE 0660) the basic units to the accessories. The 3RH1 contactor relays are suitable for use in any climate. Contactor relays and coupling relays They are finger-safe according to EN 50274. Size S00 with accessories The 3RH1 contactor relays have screw or Cage Clamp termi- nals. Four contacts are available in the basic unit. 1 Contactor relay, see page 3/70 2 Coupling relay for auxiliary circuits, see page 3/78 3 Solid-state time-delay block, ON-delay, see page 3/106 4 Solid-state time-delay block, OFF-delay, see page 3/106 5 Auxiliary switch block with solid-state time delay, see page 3/105 (versions with ON or OFF-delay) 6 1-pole auxiliary switch block, cable entry from above, see page 3/100 7 2-pole auxiliary switch block, cable entry from above, see page 3/100 8 1-pole auxiliary switch block, cable entry from below, see page 3/100 9 2-pole auxiliary switch block, cable entry from below, see page 3/100 10 4-pole auxiliary switch block, see page 3/100 (terminal designations according to EN 50011 or EN 50005) 11 2-pole auxiliary switch block, standard version or solid-state compatible version, see page 3/100 (terminal designations according to EN 50005) 12 Solder pin adapter for contactor relays with 4-pole auxiliary switch block, see page 3/111 13 Solder pin adapter for contactor relays and coupling relays, see page 3/110 14 Additional load module for increasing the permissible residual current, see page 3/109 15 Surge suppressor with LED, see page 3/108 16 Surge suppressor without LED, see page 3/108 Siemens LV 1 2009 3/69 3LV1 09 Gesamt EN.book Seite 70 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 3RH, 3TH Contactor Relays 3RH1 contactor relays, 4- and 8-pole Selection and ordering data AC and DC operation PU (UNIT, SET, M) = 1 PS* = 1 unit PG = 101 Size S00 3RH11 ..-1... 3RH11 ..-2... 3RH12 ..-1... 3RH12 ..-2... Rated opera- Contacts Rated control DT Screw terminals Weight DT Cage Clamp Weight tional current supply voltage U per PU terminals per PU s I /AC-15/AC-14 approx. approx. e at 230 V Ident. Version Order No. Price Order No. Price No. per PU per PU ANO NC V AC kg kg For screw and snap-on mounting onto 35 mm standard mounting rail Terminal designations according to EN 50011 1) 50/60 Hz AC operation 640 E4-- 24 3RH11 40-1AB00 0.200 3RH11 40-2AB00 0.200 110 3RH11 40-1AF00 0.200 3RH11 40-2AF00 0.200 230 3RH11 40-1AP00 0.200 3RH11 40-2AP00 0.200 31 E3124 3RH11 31-1AB00 0.200 3RH11 31-2AB00 0.200 110 3RH11 31-1AF00 0.200 3RH11 31-2AF00 0.200 230 3RH11 31-1AP00 0.200 3RH11 31-2AP00 0.200 22 E2224 3RH11 22-1AB00 0.200 3RH11 22-2AB00 0.200 110 3RH11 22-1AF00 0.200 3RH11 22-2AF00 0.200 230 3RH11 22-1AP00 0.200 3RH11 22-2AP00 0.200 With permanently mounted auxiliary switch block for safety applications according to SUVA 644 E44230 3RH12 44-1AP00 0.250 B 3RH12 44-2AP00 0.250 62 E62230 3RH12 62-1AP00 0.250 B 3RH12 62-2AP00 0.250 DC operation DC solenoid system 640 E4-- 24 3RH11 40-1BB40 0.260 3RH11 40-2BB40 0.260 220 3RH11 40-1BM40 0.260 B 3RH11 40-2BM40 0.260 31 E3124 3RH11 31-1BB40 0.260 3RH11 31-2BB40 0.260 220 3RH11 31-1BM40 0.260 B 3RH11 31-2BM40 0.260 22 E2224 3RH11 22-1BB40 0.260 3RH11 22-2BB40 0.260 220 3RH11 22-1BM40 0.260 B 3RH11 22-2BM40 0.260 With permanently mounted auxiliary switch block for safety applications according to SUVA 644 E4424 3RH12 44-1BB40 0.310 A 3RH12 44-2BB40 0.310 62 E6224 3RH12 62-1BB40 0.310 A 3RH12 62-2BB40 0.310 For other voltages see page 3/71, for contactors with perma- nently mounted auxiliary switch block please inquire. For accessories, see page 3/100 and 3/102. For multi-unit packing and reusable packaging, see Appendix -> Order informatio. 1) Coil operating range at 50 Hz: 0.8 to 1.1 x U s at 60 Hz: 0.85 to 1.1 x U . s * You can order this quantity or a multiple thereof. Siemens LV 1 2009 3/70 3