DC Voltage Falcon F35 Series Digital Panel Meter Full 3-1/2 Digit, Bright Red 0.56 (14.2mm) Display Broad Range Display Scaling Short 2.94 (74.7mm) Deep, 1/8 DIN Case Screw Terminal Connector for Easy Installation Four User-Settable Ranges: 200mV, 2V, 20V, 200V Jumper-Selectable Decimal Point Optional Isolated 9-32VDC Power Supply Optional Excitation Output of 12VDC or 24VDC The Falcon Series digital indicators are premium quality Compactly designed for applications requiring minimal rear 1/8 DIN meters for industrial applications. All Falcon units panel depth, the Falcon fits a standard 1/8 DIN panel cutout feature jumper selectable decimal point (internal and on the (92mm x 45mm) and requires less than 3 behind the panel. connector for remote decimal point) and display scaling, A screw terminal connector is a standard feature for easy providing wide application flexibility. In addition, signal input wiring of the power supply and signal input connections. ranges are easy to change with jumpers on the main board. The Falcon has a 0.56 bright red LED display for high vis- ibility. Installation and Panel Cutout 4.04 102.5mm 3.59 91.2mm Engineering Label 1.77 45mm 3.62 91.9mm Mounting Requirements The Falcon series 1/8 DIN indicators require a panel cutout of 1.77 (45mm) high by 3.62 (92mm) wide. To install the Falcon into a panel cut- out, remove the clips from the side of the meter. Slide the meter through 2.94 0.51 3.78 13mm 74.7mm your panel cutout, then slide the mounting clips back on the meter. Press 96mm evenly to ensure a proper fit. 1.74 1.89 Engineering Label Placement 44.2mm 48mm 2.28 If replacement of the engineering unit label is required, place the tip of a 57.9mm ball-point pen into the small hole at the base of the engineering label in the bezel. Slide the label up until it pops out. Grasp and remove. Slide the new label half the distance in, then use the ball-point pen to slide it down into place.Specifications DISPLAY ENVIRONMENTAL MECHANICAL Type: 7-segment, red LED Operating Temperature: 0 to 55C Bezel: 3.79 x 1.89 x .51 Height: 0.56 (14.2mm) Storage Temperature: -10 to 60C (96 x 48 x13mm) Decimal Point: 3-position programmable, Relative Humidity: 0 to 85% non-condensing Depth: 2.94 (74.7mm) internally or on the terminal block Temperature Coefficient: Panel Cutout: 3.62 X 1.77 Overrange indication: most significant (0.01% of input 0.05 count)/C (91.9 x 45mm 1/8 DIN) digit = 1 other digits blank Warm-up Time: Less than 15 minutes Case Material: 94V-1, UL rated Noryl Polarity: Automatic, with indication, Weight: 9.0oz (255.1g) indication implied NOISE REJECTION NMRR: 50dB, 50/60Hz INPUTS: DC Voltage POWER REQUIREMENTS CMRR: (with 1K unbalanced 60Hz): Input Display Input Maximum AC Voltages: 120 or 220VAC, 10%, 90dB min. Range Resolution Impedance Overload 50/60Hz 200mV 100 V 100M 100V DC Voltages: 9-32VDC, 1% ANALOG TO DIGITAL CONVERSION 2V 1mV 10M 250V Power Consumption: 3VA Technique: Dual slope integration 20V 10mV 10M 250V Rate: 3 samples per second, nominal 200V 100mV 9.9M 250V ACCURACY 25 C 0.1% of reading 1 count Wiring Diagram Decimal Point Selection 1 2 3 45 67 8 9 10 11 12 From terminal block: The decimal point can be set from the rear screw terminal block by connecting the appropriate decimal point (DP 1, 2, 3, ) to the DP C terminal. The J105 jumper must be in the D position (see diagram underFrom front pane). Input Signal: Connect the signal to be monitored to the IN HI and Decimal IN LO terminals. IN HI is terminal 1, IN LO is terminal 2. Point Connect 1 2 3 45 67 8 9 10 11 12 1.999 DP C to DP1 Supply Power: Connect the supply power to terminals 11 and 19.99 DP C to DP2 199.9 DP C to DP3 12. Note that if AC power is supplied, terminal 11 is for Neutral, 1999 No Decimal and terminal 12 is for Hot. If DC power is used, terminal 11 is for -DC, and 12 is for +DC. From front panel: The decimal point can also be selected by removing the front bezel from the meter. Move the push-on jumper Display Hold: This feature allows you to hold the displayed value J105 across the correct letter. indefinitely. A remote switch can be used to make the connection. To activate the display hold, pins 3 and 4 (Hold +REF). This con- Decimal Jumper nection must be kept isolated from other circuitry. To hold multiple Point Position at J105 units, separate poles of the switch must be used to maintain the 1.999 A isolation. 19.99 B 199.9 C These instruments are designed for maximum safety to the 1999 D* operator when mounted in a panel according to instructions. * No Decimal Point They are not to be used unmounted or for exploratory mea- surements in unknown circuits. Before switching the instrument on, make sure the supply volt- age matches the power source required of the instrument as indicated on the hook-up label affixed to the instrument. Voltage Range Selection All Falcon Indicators are configured initially per the customer specifica- Note: JU101 and JU102 are hard wire jumpers, and are removed by tions. Range changes can be accomplished as follows: cutting them. Resoldering the JU jumpers is not recommended. If this is required, or if a function is to be changed (from volts to current), Simpson Disconnect power from the unit. Remove the unit from the panel. recommends returning the Falcon to the factory or an Authorized Service Remove the front bezel by inserting slotted screwdriver in the vertical Center. After moving the jumpers to the desired location, put the Falcon slots on either side of the bezel and then turning to pry the bezel off. back together and install in your panel, or proceed to calibration. Unscrew the two Phillips head screws at either side of the circuit board. Finally, push on the green connector assembly in the back of the unit J101 to slide the main circuit board out from the meter. Change jumpers JU101 JUMPER V A POSITION according to the chart below. AT ON J101 FOR AMPS J102 JU102 FOR VOLTS T101 Note: If a new range is selected, the calibration procedure must also A be performed. J103 J104 Input J103 J106 JU101 JU102 R J106 JUMPER POSITION Range AT ON J103 JU106 JU112 JUMPER POSITION FOR 2V. AT ON J106 200mV C R V Yes 2V A R V No See Chart 20V B R V No 200V D R V No A B C D E IN HI IN LO HOLD +REF DP 1 DP2 DP3 DP C +EXC -EXC AC GND AC LO -DC AC HI +DC IN HI IN LO HOLD +REF DP 1 DP2 DP3 DP C +EXC -EXC AC GND AC LO -DC AC HI +DC