Hawk 3 Digital Panel Meter / Controller File E199939 All parameters set from easy to understand front panel access One, two or four 5-amp relays optional Five user-selectable brightness levels 1/8 DIN, shallow depth case, 3.24 RS485 digital communications optional (H345) 12 or 24 DCV Excitation output optional, maximum 30mA 12V and 20mA 24V 4-20mA or 0-10 DCV analog retransmission optional NEMA 4X rated front panel 1 Rev. 04-15Hawk 3 Digital Panel Meter / Controller Specifications Specifications - Cont DISPLAY ENVIRONMENTAL Type 7- segment, red LED, 4 or 5 digits Operating Temperature 0 to 50C Height 0.56 (14.2mm) Storage Temperature -10 to +60C Brightness 5 settings, user programmable Relative Humidity < 80% for the temp. up to 31C and decreasing linearly to 50% relative humidity at 50C Decimal Point 4 or 5 position, user programmable Ambient Temp 25C Overrange Indication Display flashes EEEE indicating Maximum Value Exceeded (Example: H335) Temperature Drift 100 ppm /C Warmup time 10 minutes Underrange Indication Display flashes -EEE indicating Minimum Value Exceeded (Example: H335) Alarm Indicators 4 LED indicators for up to four independent NOISE REJECTION setpoints NMRR 60 dB 50-60 Hz Linearization H335 2 points CMRR 70 db 50-60 Hz H345 16 points For indoor use to an altitude up to 200m POWER REQUIREMENTS A TO D CONVERSION AC 85 to 250 VAC or 120VAC 10VA Technique Successive approximation with oversampling DC 9 to 36 DCV 10VA Sample Rate 10 conversions per second Isolation 250V RMS MAX Display Rate User Programmable from 1 - 420 updates / Note: Each supply is shown at the maximum and minimum values minute (240 default) except the 120 VAC unit, which is allowed 10% ACCURACY 25C as % of rdg RS-485 Specications (only available on H345) 4-1/2 digit 3-1/2 digit 2 wire / Half duplex, Baud rate: 9600 baud, 1ms delay per character, DC Current 32 Nodes Maximum on Bus. High (5A, 2A) 0.2% of reading 0.3% of reading Optically and magnetically isolated for ground loop elimination 1 count 1 count All others 0.05% of reading 0.1% of reading 1 count 1 count MECHANICAL DC Volts Bezel 3.92 x 2.0 x 0.52 (99.8mm x 51.9mm x High (600V) 0.1% of reading 0.2% of reading 132mm) 1 count 1 count Depth 3.24 (82.3mm) behind panel All others 0.05% of reading 0.1% of reading 1 count 1 count Panel cutout 3.62 x 1.77 (92mm x 45mm) 1/8 DIN Resistance Weight 10 oz. (283.5 g) All ranges 0.1% of reading 0.1% of reading Cover NEMA 4X Rated front panel 2 counts 2 counts * AC Current ELECTRICAL High (2A, 5A) 0.2% of reading 0.3% of reading 2 counts 2 counts Accuracy Listed as % of reading at 25C. All others 0.1% of reading 0.2% of reading Add 100ppm/C to compensate for drift. 2 counts 2 counts Tested at 50Hz, include +/-1 count for every * AC Volts 100Hz above 50 Hz High (600V) 0.1% of reading 0.2% of reading Transient Overvoltage Installation Category III, Pollution Degree 2 1 count 1 count Analog Output Sampling Rate = 100 mSec. All others 0.05% of reading 0.1% of reading 1 count 1 count Reaction Time 0 to Full Scale = 10 Sec * AC functions measured at 50 hz, include 1 count for each additional 100 Hz above 50 Hz 2 Rev. 04-15