20W Single Output 20W Single Output GB20 Family GB20 Family Medical & Industrial Grade Medical & Industrial Grade FEATURES AND BENEFITS rd 20W Open Frame and PCB-mount Power Supply Approved to CSA/EN/IEC/UL60601-1, 3 Edition Medical 1.6 x 3.38 x 1.0 Package E-cap Life of >7 Years Universal Input 90-264VAC >1,000,000 Hours MTBF <0.1W No Load Input Power 3 Year Warranty Industrial Approved to CSA/EN/IEC/UL62368-1 Meets Class B Radiated & Conducted EMI, with Margin Meets Heavy iIndustrial and IEC60601-1-2 th 4 Edition Levels of EMC Note: *Consult Factory for compliance information. MODEL SELECTION Rated Output Ripple & Line Load Input Output 2 Model Number Volts 1 Current Power Noise Regulation Regulation Class/Termination Termination Class I (Grounded) input, 75mV pk-pk GB20S05K01 5.0V 3.0A 15W 1% 5% 3-pin AMP/Molex type 4-pin AMP/Molex type GB20S07K01 7.5V 2.0A 15W 75mV pk-pk 1% 5% connector connector for K and C Change K to C for versions GB20S09K01 9.0V 2.0A 18W 90mV pk-pk 1% 5% class II input 120mV pk-pk GB20S12K01 12.0V 1.5A 18W 1% 5% Change K to P for PCB 120mV pk-pk GB20S15K01 15.0V 1.2A 18W 1% 5% mount pins, class I input PCB mount pins for P and V versions 240mV pk-pk GB20S24K01 24.0V 0.8A 20W 1% 5% Change K to V for PCB mount pins, class II input GB20S48K01 0.4A 20W 480mV pk-pk 1% 5% 48.0V Note: 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 2. Other output voltages available, consult factory. 3. All specifications are typical at 230VAC, full load, at 25C ambient unless noted. INPUT OUTPUT <700ms Input Voltage and Turn On Time 100-240VAC, 10%, 47-63Hz, 1 Frequency Hold-Up Time 20ms/100VAC at full load Input Current 115VAC: 0.5A, 230VAC: 0.2A 15W-20W continuous See models chart for specific Output Power 264VAC, cold start: will not exceed 40A peak Inrush Current voltage model ratings Input Fuses 3.15A, 250VAC fuse in both line and neutral Output Voltage See models chart Earth Leakage Current <500A 264VAC, 60Hz, NC 500s resp.time for return to w/in 0.5% of final (Input to Ground) <1mA 264VAC, 60Hz, SFC value for any 50% load step from 5% to 100% of Transient Response rated load, i/t<0.2A/s Earth Leakage Current <100A 264VAC, 60Hz, NC Max voltage deviation is +/-3.5% (Output to Ground) <500A 264VAC, 60Hz, SFC Regulation See models chart Efficiency >88%, typical Note: All specifications are typical at 230VAC input, full load, at 25C ambient unless noted. 0.9, min., 230VAC, 80-100% load vector, 25C Power Factor ambient Note: All specifications are typical at 230VAC input, full load, at 25C ambient unless noted. GB20 Datasheet v0721 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 1 20W Single Output 20W Single Output 20W Single Output GB20 FGB20 Familyamily GB20 Family Medical & Industrial Grade Medical & Industrial Grade Medical & Industrial Grade PROTECTION SAFETY Will shutdown upon an overtemperature condition, Overtemperature ITE/Industrial Safety EN/IEC/UL62368-1 Auto-recovery Protection rd Medical Safety EN/IEC/UL60601-1, 3 edition 130% to 160% of rated output current value, Overload Protection Hiccup mode Hiccup mode Short Circuit Protection EMI/EMC COMPLIANCE 120% to 150% of nominal output voltage, Overvoltage Protection Hiccup Mode EN55032, EN55011/CISPR11 Class B, FCC Part Conducted Emissions 15.107, Class B: 6db margin type, at 115 and 230VAC EN55032, EN55011/CISPR11 Class B, FCC Part Radiated Emissions RELIABILITY 15.109, Class B: 3db margin type, at 115 and 230VAC Electro-Static Discharge EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, >1,000,000 hours, full load, 110 & 220VAC input, (ESD) Immunity on +/- 15kV air, Criteria A MTBF 25C amb., per telcordia 332 issue 6, stress method th Power Ports IEC60601-1-2, 4 edition, Table 4 >7 year life based on calculations at 115VAC/60Hz EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, E-cap Life & 230VAC/50Hz, ambient 25C at 24 hrs per day, Radiated RF EM Fields 80% AM at 1kHz 365 days/year, 6 power up cycles per day Susceptibility th IEC60601-1-2, 4 edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, Electrical Fast 100Khz rep rate, 40A, Criteria A Transients (EFT)/Bursts ISOLATION SPECIFICATIONS th IEC60601-1-2, 4 edition, Table 5 Surges, Line to Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, Input-Output : 4000VAC (2 MOPP) (Diff Mode) and Line to +/-4kV CM, Criteria A Isolation Input-Ground : 1500VAC (1 MOPP) th GND (CMN Mode) Surpasses IEC60601-1-2, 4 edition requirements Output-Ground : 1500VAC (1 MOPP) EN55022/IEC61000-4-6, 3.6V/m Level 4, (0.15 to Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: TBD Conducted Disturbances 80Mhz and 12V/m) in ISM and amateur radio bands Induced by RF Fields between 0.15Mhz and 80Mhz, 80% AM at 1KHz th IEC60601-1-2, 4 edition, Table 5 ENVIRONMENT Rated Power Frequency EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60Hz th Magnetic Fields IEC60601-1-2, 4 edition, Table 4 -25 ~ +70C, see derating curve for operation above Operating Temperature 40C EN55024/IECEN61000-4-11: --100% dip for 10 ms, at 0, 45, 90, 135, 180, 225, StorageTemperature -40C ~ +85C 270 and 315 degrees, 100% dip for 20ms, 0 deg., Voltage Interruptions, Criteria A Convection Cooling Dips, Sags & Surges --100% dip for 5000ms (250/300 cycles), Criteria B --60% dip for 100ms, Criteria B Relative Humidity 5% to 90%, Non-condensing --30% dip for 500ms, Criteria A th Operating: 0.003g/Hz, 1.5grms overall, 3 axes, IEC60601-1-2, 4 edition, Table 5 10 min/axis, 1-500Hz Harmonic Current Non-Oper.: random waveform, 3 minutes per axis, 3 EN55011/EN61000-3-2, Class A Vibration Emissions axes and sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave/minutes, Flicker Test EN61000-3-3 vibration time of 10 sweeps/axes, 3 axes Note: 1. The power supply is considered a component which will be installed into a final equipment. Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks The final equipment must be re-confirmed that it still meets EMC directives. total 2. All specifications are typical at nominal input, full load, at 25C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Shock Non-Operating: Half-sine waveform, impact acceleration of 50G, pulse duration of 6ms, Number of shocks: 3 for each of the three axis 41 x 86 x 25mm Dimensions 1.6 x 3.38 x 1.0 inch Weight 120g Note: Same dimensions for PCB & Pin Variants. GB20 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. GB20 Datasheet v0721 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 2