150W Single Output GE150 Family External Medical / ITE Power Supply FEATURES AND BENEFITS Compact Size: 6.5 x 2.8 x 1.5 Approved to EN/IEC/UL62368-1 Meets UL/EN/IEC60601-1-2, 4th Edition for EMC Approved to EN/IEC/UL60601-1, 3rd Edition No Load Input Power Meets DoE Efficiency Level VI Up to 150W of AC-DC Power Universal Input 85-264Vac Input Range Meets EN55011/CISPR11, FCC Part 15.109 E-Cap Life of >5 years 3 Year Warranty IP22 Rated Enclosure MODEL SELECTION Output Output Line Load Output Cable/ Input Model Number Volts Ripple & Noise Current Power Regulation Regulation Connector Configuration GE150A1251F01 12.0V 12.1A 145W 120mV pk-pk 1% 5% 16AWG, 1165mm, 4 cond., 6 pin GE150A1551F01 15.0V 9.67A 145W 150mV pk-pk 1% 5% Molex Mini-fit Class I Desktop, IEC60320 C14 GE150A1851F01 18.0V 8.33A 145W 180mV pk-pk 1% 5% Receptacle 18AWG, 1165mm, GE150A2451F01 24.0V 6.25A 150W 240mV pk-pk 1% 5% 4 cond., 6 pin Molex Mini-fit GE150A4851F01 48.0V 3.13A 150W 480mV pk-pk 1% 5% GE150A1251N01 12.0V 12.5A 145W 120mV pk-pk 1% 5% 16AWG, 1165mm, 4 cond., 6 pin GE150A1551N01 15.0V 10.0A 145W 150mV pk-pk 1% 5% Molex Mini-fit Class II Desktop, IEC60320 C8 GE150A1851N01 18.0V 8.33A 145W 180mV pk-pk 1% 5% Receptacle 18AWG, 1165mm, GE150A2451N01 24.0V 6.25A 150W 240mV pk-pk 1% 5% 4 cond., 6 pin Molex Mini-fit GE150A4851N01 48.0V 3.20A 150W 480mV pk-pk 1% 5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output return (-), insert a B in the part number where the A is located (ME150B1251F01). 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. GE150 Datasheet V0920 Copyright 2020 SL Power Electronics Corp. All rights reserved. Page 1150W Single Output GE150 Family External Medical / ITE Power Supply INPUT OUTPUT Output Voltage See models chart on pg 1. AC Input 100-240Vac, 10%, 47-63Hz, 1 Up to 150 Watts lower voltage -> Input Current 115Vac: 2.2A, 230Vac: 1.1A Output Power lower power Inrush Current 264Vac, cold start: will not exceed 60A Turn On Time Less than 1 sec 115Vac, full load F1, F2: 3.15A, 250Vac fuses (line & Input Fuses Hold-up Time 20mS min., at full Load, 100Vac input neutral lines) provided on all models Ripple and Noise See models chart on pg 1 Input-GND: <500A 264Vac, 60Hz, Total Regulation See models chart on pg 1 Earth Leakage Current NC Output- GND: Output-GND: 500s response time for return to within <50uA 264Vac, 60Hz, NC 0.5% of final value for any 50% load Efficiency >88%, typical Transient Response step over the range of 5% to 100% of <0.150W (meets DoE Efficiency Level rated load, i/t< 0.2A/s. Max. voltage No Load Input Power VI and CoC Tier 2 Requirements) deviation is +/-3.5%. PROTECTION Overtemperature Protection Will shut down upon an overtemperature condition, auto-recovery Overload Protection 125 to 180% of rating, Hiccup Mode Short Circuit Protection Hiccup Mode, auto recovery Overvoltage Protection 130 to 150% of output voltage, Hiccup mode EMI/EMC COMPLIANCE Conducted Emissions EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A IEC60601-1-2, 4th on Power Ports Edition, Table 4 EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Radiated RF EM Fields Susceptibility IEC60601-1-2, 4th Edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A IEC60601-1-2, Electrical Fast Transients (EFT) /Bursts 4th Edition, Table 5 Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A Surpasses to GND (CMN Mode) IEC60601-1-2, 4th Edition requirements Conducted Disturbances induced by RF EN55022/IEC61000-4-6, 3V/m Level 4, 0.15 to 80Mhz and 12V/m) in ISM and radio Fields bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz IEC60601-1-2, 4th Edition, Table 5 Rated Power Frequency Magnetic Field EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz IEC60601-1-2, 4th Edition, Table 4 Harmonic Current Emissions EN55011/EN61000-3-2, Class A EN55024/IECEN61000-4-11: 100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, Criteria A 100% dip for 20mS, Criteria A 100% dip for 5000mS (250/300 Voltage Interruptions, Dips, Sags & Surges cycles), Criteria B 60% dip for 100mS, Criteria B 30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 GE150 Datasheet V0920 Copyright 2020 SL Power Electronics Corp. All rights reserved. Page 2