GPC80 Commercial/GPM80 Medical 80 Watt Global Single and Multiple Output Performance Switchers PERFORMANCE MEDICAL SWITCHERS FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Medical & Industrial Approved to EN/CSA/IEC/UL62368-1 RoHS Compliant Model Available (G suix) SPECIFICATIONS Ac Input Output Noise 85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Input Current Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A Transient Response Main output500 s typical response time for return to within 0.5% of final value Hold-Up Time for a 50% load step change. i/t<0.2 A/s. Maximum voltage deviation is 3.5%. 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Startup/shutdown overshoot less than 3%. Output Power Remote Sense 80 W continuous, 110 W with air flow. Peak ratings are for 60 s maximum Provided as a standard feature on single-output models. duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. Voltage Adjustment Built-in potentiometer adjusts voltage 5% on outputs 1 & 2. Overload Protection Fully protected against short circuit and output overload. Short circuit protec- EMI/EMC Compliance tion is cycling type power limit on outputs 1 & 2 foldback type on outputs 3 All models include built-in EMI filtering to meet the following emissions & 4. Recovery after fault is automatic. Factory set to begin power limiting at requirements: 120 W. See output ratings chart for additional notes or conditions. EMI SPECIFICATIONS COMPLIANCE LEVEL Overvoltage Protection Conducted Emissions GPC80 EN55022 Class B FCC Class B Main outputs: 124% 12% typical. Conducted Emissions GPM80 EN55011Class B FCC Class B Efficiency Static Discharge EN61000-4-2, 6 kV contact, 8 kV air 70% at full rated load, nominal input voltage, depending on model and load RF Field Susceptibility EN61000-4-3, 3 V/meter distribution. Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Input Protection Line Frequency Harmonics EN61000-3-2 Class A Internal ac fuse provided. Designed to blow only if a catastrophic failure oc- curs in the unit. Commercial Leakage Current 0.7 mA 254 Vac 60 Hz input. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start Commercial Safety conditions will not exceed 34 A. Approved to EN/CSA/IEC/UL62368-1. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV Temperature Coefficient 0.03%/C typical on all outputs. under normal and single fault conditions. Environmental Medical Leakage Current Designed for 0 to 50C operation at full rated output power derate output 35 A 254 Vac 60 Hz input. current and total output power by 2.5% per C above 50C. See Environmen- tal and Packaging Specifications on next page. Medical Commercial Safety Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 and IEC601.1. UL file E116994 Power Fail (optional) CSA LR46516. The output(s) are intended for safety earthed Signal Output and TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and The signal is factory set to trip on 84 to 94 Vac brown-out depending upon single fault conditions. incoming line impedance and distortion. Other settings are available to the user through adjustment of built-in potentiometer (consult factory for as- sistance). For Power fail option, add -PF after model number. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical RoHS Output Output Output Total Model Model Suffix* Output No. Output Minimum Maximum (B) Maximum ( C ) Output Peak Noise P-P Regulation (A) 12 A 16 A 50 mV 2% GPC80A GPM80A G 1 +5 V 1.0 A 12 A 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 1.2 A 1.2 A 120 mV 3% 3 -12 V 0 A 1 A 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80B GPM80B G 1 +5 V 1.0 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 -5 V 0 A 1 A 1.2 A 1.2 A 50 mV 3% GPC80C GPM80C G 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% GPC80D GPM80D G 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0 A 2 A 3 A 4 A 240 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80 E GPM80E G 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 3 A 4 A 240 mV 2% 2 +24 V 0 A 2 A 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A GPC80P GPM80P G 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0.5 A 3.5 A 4.5 A 4.5 A 400 mV +10%/-5% D 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 2 A 2 A 2.5 A 120 mV 3% GPC80-5 GPM80-5 G 1 5 V 0 A 16 A 20 A 22 A 50 mV 2% GPC80-12 GPM80-12 G 1 12 V 0 A 6.7 A 9.2 A 9.2 A 120 mV 2% GPC80-15 GPM80-15 G 1 15 V 0 A 5.3 A 7.3 A 7.3 A 150 mV 2% GPC80-24 GPM80-24 G 1 24 V 0 A 3.4 A 4.6 A 4.6 A 240 mV 2% GPC80-28 GPM80-28 G 1 28 V 0 A 2.9 A 3.9 A 3.9 A 280 mV 2% GPC80-48 GPM80-48 G 1 48 V 0 A 1.7 A 2.3 A 2.3 A 480 mV 2% * Add G suffix to part number for RoHS compliant model. Contact factory for availability. A. Total regulation is denfi ed as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Ratings for unrestricted natural convection cooling output 1 & 2 combined load not to exceed 14A continuous total power = 80W. C. Ratings with 26 cfm forced air cooling output 1 & 2 combined load not to exceed 16A continuous total power = 110W. D. To maintain these regulation conditions, the +5V current must be at least 1/4 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted within 1% with at least a 1A load to maintain regulation on this input. E. For Power Fail option, add -PF after the model number. GPC80/GPM80 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) See individual specs -40 to +85C A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g pk pk orthogonal axes, total 6 shocks. C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to Altitude -500 to 10,000 ft -500 to 40,000 ft 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms hr./axis non-operating. SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone: (805) 486 4565 Fax: (805) 487 8911 Email: sl slpower.com Rev. 12/06. Data Sheet 2006 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.