10W-12W Single Output External Power 10W-12W Single Output External Power ME10 Family ME10 Family Medical Grade Medical Grade FEATURES AND BENEFITS Meets EN55011/CISPR11, FCC Part 15.109 Meets UL/EN/IEC60601-1-2, 4th Edition for Medical Class B Conducted & Radiated Emissions, with EMC* 6db Margin Approved to EN/IEC/UL60601-1, 3rd Edition E-Cap Life of >7 Years Applications with Isolation Levels which Satisfy the 2 MOPP Requirements >10,00,000 Hours MTBF Meets DoE Efficiency Level VI Requirements IP22 Rated Enclosure No Load Input Power Average Efficiency 3 Years Warranty Note: * Consult Factory for Table 9 compliance information. Up to 12W of AC-DC Power * IP22 does not include interchangeable blade versions. Universal Input 90 - 264VAC Input Range LPS Desktop and Wall-plug Versions MODEL SELECTION Output Output Ripple & Line Load Output Input Model Number Volts 1 Current Power Noise Regulation Regulation Connector Configuration 75mV pk-pk ME10A0503F01 5.0V 2.0A 10W 1% 5% 75mV pk-pk ME10A0603F01 5.9V 1.6A 10W 1% 5% 75mV pk-pk ME10A0703F01 7.5V 1.3A 10W 1% 5% 2.5 x 5.5 x 9.5mm Class I Desktop, Straight barrel type, IEC60320 C14 ME10A0903F01 9.0V 1.1A 10W 90mV pk-pk 1% 5% Center positive receptacle ME10A1203F01 12.0V 1.0A 12W 120mV pk-pk 1% 5% 150mV pk-pk ME10A1503F01 15.0V 0.8A 12W 1% 5% 24.0V 0.5A 12W 240mV pk-pk 1% 5% ME10A2403F01 5.0V 2.0A 10W 75mV pk-pk 1% 5% ME10A0503N01 75mV pk-pk ME10A0603N01 5.9V 1.6A 10W 1% 5% 75mV pk-pk ME10A0703N01 7.5V 1.3A 10W 1% 5% Class II 2.5 x 5.5 x 9.5mm Desktop, 90mV pk-pk Straight barrel type, ME10A0903N01 9.0V 1.1A 10W 1% 5% IEC60320 C8 Center positive receptacle 120mV pk-pk ME10A1203N01 12.0V 1.0A 12W 1% 5% 150mV pk-pk ME10A1503N01 15.0V 0.8A 12W 1% 5% 12W 240mV pk-pk 5% ME10A2403N01 24.0V 0.5A 1% 75mV pk-pk ME10A0503Q01 5.0V 2.0A 10W 1% 5% ME10A0603Q01 5.9V 1.6A 10W 75mV pk-pk 1% 5% ME10A0703Q01 7.5V 1.3A 10W 75mV pk-pk 1% 5% Class II 2.5 x 5.5 x 9.5mm Desktop, 90mV pk-pk Straight barrel type, ME10A0903Q01 9.0V 1.1A 10W 1% 5% IEC60320 C18 Center positive receptacle ME10A1203Q01 120mV pk-pk 12.0V 1.0A 12W 1% 5% ME10A1503Q01 15.0V 0.8A 150mV pk-pk 5% 12W 1% 240mV pk-pk ME10A2403Q01 24.0V 0.5A 12W 1% 5% ME10 Datasheet v1121 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 1 ME10 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.10W-12W Single Output External Power 10W-12W Single Output External Power 10W-12W Single Output External Power ME10 Family ME10 Family ME10 Family Medical Grade Medical Grade Medical Grade MODEL SELECTION Output Output Ripple & Line Load Output Input Model Number Volts 1 Current Power Noise Regulation Regulation Connector Configuration 75mV pk-pk ME10A0503B01 5.0V 2.0A 10W 1% 5% 75mV pk-pk ME10A0603B01 5.9V 1.6A 10W 1% 5% Class II 75mV pk-pk ME10A0703B01 7.5V 1.3A 10W 1% 5% Wall-plug, 2.5 x 5.5 x 9.5mm Interchangeable 90mV pk-pk ME10A0903B01 9.0V 1.1A 10W 1% 5% Straight barrel type, blades (North Center positive American blade 120mV pk-pk ME10A1203B01 12.0V 1.0A 12W 1% 5% included) 150mV pk-pk ME10A1503B01 15.0V 0.8A 12W 1% 5% 240mV pk-pk 24.0V 0.5A 12W 1% 5% ME10A2403B01 75mV pk-pk ME10A0503C01 5.0V 2.0A 10W 1% 5% 75mV pk-pk ME10A0603C01 5.9V 1.6A 10W 1% 5% 75mV pk-pk ME10A0703C01 7.5V 1.3A 10W 1% 5% Class II 2.5 x 5.5 x 9.5mm Wall-plug, Fixed Straight barrel type, 90mV pk-pk ME10A0903C01 9.0V 1.1A 10W 1% 5% North American Center positive blades 120mV pk-pk 1% 5% ME10A1203C01 12.0V 1.0A 12W 150mV pk-pk 15.0V 12W 1% ME10A1503C01 0.8A 5% 240mV pk-pk ME10A2403C01 24.0V 0.5A 12W 1% 5% Note: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1F ceramic and 47F low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia). 3. For EU fixed blades, replace C in the model number with M, for UK blades, replace C with G, for Australia blades, replace C with H. 4. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (ME10B0503F01). 5. All specifications are typical at nominal input, full load, at 25C ambient unless noted. INPUT OUTPUT AC Input 100-240VAC, 10%, 47-63Hz, 1 Hold-Up Time 20ms min at full load, 100VAC input Turn On Time Less than 700ms 115VAC, Full load Input Current 115VAC: 0.45A, 230VAC: 0.22A Patient Leakage 264VAC, cold start: will not exceed 40A Inrush Current <100A 264VAC, 60Hz, NC Current <500A 264VAC, 60Hz, SFC F1, F2: 3.15A, 250Vac fuses (line & neutral lines) (Output to Earth) Input Fuses provided on all models 10 to 12W continuous - See models chart for Output Power specific voltage model ratings Earth Leakage Current <500A 264VAC, 60Hz, NC (Input to Ground) <1mA 264VAC, 60Hz, SFC Output Voltage See models chart Efficiency >87%, Typical Ripple and Noise See models chart <0.1W per DoE Efficiency Level VI requirements No Load Input Power 500s response time for return to within 0.5% of final value for any 50% load step over the range of Transient Response 5% to 100% of rated load, i/t< 0.2A/s Max voltage deviation is +/-3.5% Regulation See models chart ME10 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. ME10 Datasheet v1121 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 2 ME10 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.