150W Single Output ME150 Family External Medical Power Supply FEATURES AND BENEFITS Medical Compact Size: 6.5 x 2.8 x 1.5 Meets UL/EN/IEC60601-1-2, 4th Edition for EMC* Approved to EN/IEC/UL60601-1, 3rd Editionwith Isolation Meets DoE Efficiency Level VI and EU CoC Version 5, Levels which Satisfy the 2 MOPP Requirements Tier 2 Requirements No Load Input Power Average Efficiency Up to 150W of AC-DC Power Universal Input 85-264Vac Input Range Meets EN55011/CISPR11, FCC Part 15.109 Class B E-Cap Life of >10 years Conducted & Radiated Emissions, w/6db Margin IP22 Rated Enclosure >3M Hours MTBF 3 Year Warranty** MODEL SELECTION Output Output Ripple & Line Load Input Model Number Volts Output Connector 1 Current Power Noise Regulation Regulation Configuration ME150A1251F01 12.0V 12.5A 150W 120mV pk-pk 1% 5% ME150A1551F01 15.0V 10.0A 150W 150mV pk-pk 1% 5% Class I Desktop, ME150A1851F01 18.0V 8.33A 150W 180mV pk-pk 1% 5% 6 pin Molex Type2 IEC60320 C14 Receptacle ME150A2451F01 24.0V 6.25A 150W 240mV pk-pk 1% 5% ME150A4851F01 48.0V 3.20A 150W 480mV pk-pk 1% 5% ME150A1251N01 12.0V 12.5A 150W 120mV pk-pk 1% 5% ME150A1551N01 15.0V 10.0A 150W 150mV pk-pk 1% 5% Class II Desktop, ME150A1851N01 18.0V 8.33A 150W 180mV pk-pk 1% 5% 6 pin Molex Type2 IEC60320 C8 Receptacle ME150A2451N01 24.0V 6.25A 150W 240mV pk-pk 1% 5% ME150A4851N01 48.0V 3.20A 150W 480mV pk-pk 1% 5% ME150A1251Q01 12.0V 12.5A 150W 120mV pk-pk 1% 5% ME150A1551Q01 15.0V 10.0A 150W 150mV pk-pk 1% 5% Class II Desktop, ME150A1851Q01 18.0V 8.33A 150W 180mV pk-pk 1% 5% 6 pin Molex Type2 IEC60320 C18 Receptacle ME150A2451Q01 24.0V 6.25A 150W 240mV pk-pk 1% 5% ME150A4851Q01 48.0V 3.20A 150W 480mV pk-pk 1% 5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output return (-), insert a B in the part number where the A is located (ME150B1251F01). 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. Consult factory for availability of 48V model, and models woth Q01 (C18 input receptacle). ME150 Family Datasheet v0621 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 1150W Single Output ME150 Family External Medical Power Supply INPUT OUTPUT AC Input 100-240Vac, 10%, 47-63Hz, 1 Output Voltage See models chart on pg 1. Input Current 115Vac: 2.2A, 230Vac: 1.1A Output Power 150W continuous See models chart for specific voltage model ratings Inrush Current 264Vac, cold start: will not exceed 60A Turn On Time Less than 1 sec 115Vac, full load Input Fuses F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models Hold-up Time 20mS min., at full Load, 100Vac input Earth Leakage Current Input-GND: <500A 264Vac, 60Hz, NC Output- Ripple and Noise See models chart on pg 1 GND: <4mA 264Vac, 60Hz, NC Total Regulation See models chart on pg 1 Efficiency >88%, typical 500s response time for return to within 0.5% of Transient Response No Load Input Power <0.150W (meets DoE Efficiency Level VI and CoC final value for any 50% load step over the range Tier 2 Requirements) of 5% to 100% of rated load, i/t< 0.2A/s. Max. voltage deviation is +/-3.5%. PROTECTION Overvoltage Protection 130 to 150% of output voltage, Hiccup mode Short Circuit Protection Hiccup Mode, auto recovery Over temperature Pr otection Will shutdown upon an overtemperature condition, auto-recovery Overload Protection 125 to 180% of rating, Hiccup Mode EMI/EMC COMPLIANCE Conducted Emissions EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A on Power ports IEC60601-1-2, 4th Edition, Table 4 Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz IEC60601-1-2, 4th Edition, Table 4 Electrical Fast Transients (EFT) /Bursts EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A IEC60601-1-2, 4th Edition, Table 5 Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A to GND (CMN Mode) Surpasses IEC60601-1-2, 4th Edition requirements Conducted Disturbances induced by RF EN55022/IEC61000-4-6, 3V/m Level 4, 0.15 to 80Mhz and 12V/m) in ISM and amateur radio bands between Fields 0.15Mhz and 80Mhz, 80% AM at 1KHz IEC60601-1-2, 4th Edition, Table 5 Rated Power Frequency Magnetic Field EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz Immunity IEC60601-1-2, 4th Edition, Table 4 Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: - 100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, Criteria A 100% dip for 20mS, Criteria A - 100% dip for 5000mS (250/300 cycles), Criteria B - 60% dip for 100mS, Criteria B - 30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 ME150 Family Datasheet v0621 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 2