40W Single Output External P40W Single Output External Powerower 40W Single Output External Power ME40 FME40 Familyamily ME40 Family Medical GrMedical Gradeade Medical Grade FEATURES AND BENEFITS MedicalMedical Meets UL/EN/IEC60601-1-2, 4th edition Up to 40W of AC-DC power for EMC* Meets EN55011/CISPR11, FCC Part 15.109 Approved to EN/IEC/UL60601-1, 3rd edition Class B conducted & radiated emissions, with 6db margin 2 MOPP input to output isolation IP22 rated enclosure Meets DoE efficiency level VI requirements No load input power E-cap life of >8 years Average efficiency >10,00,000 hours MTBF Universal input 90 - 264VAC input range 3 years warranty Desktop and Wall-plug versions Note: * Consult Factory for Table 9 compliance information. MODEL SELECTION Output Output Ripple & Line Load Overvoltage Output Cable Input Volts Model Number 1 Current Power Noise Regulation Regulation Trip Range & Connector Configuration ME40A0503F01 5.0V 5.00A 25W 100mV pk-pk 1% 5% 120%-150% 100mV pk-pk ME40A0903F01 9.0V 4.00A 36W 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm Class I Desktop, Straight barrel type, IEC60320 C14 ME40A1203F01 12.0V 3.40A 40W 120mV pk-pk 1% 5% 120%-150% Center positive receptacle 180mV pk-pk ME40A1803F01 18.0V 2.22A 40W 1% 5% 120%-150% 240mV pk-pk ME40A2403F01 24.0V 1.70A 40W 1% 5% 120%-140% 100mV pk-pk ME40A0503N01 5.0V 5.00A 25W 1% 5% 120%-150% 100mV pk-pk ME40A0903N01 9.0V 4.00A 36W 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm Class II Desktop, 120mV pk-pk Straight barrel type, IEC60320 C8 ME40A1203N01 12.0V 3.40A 40W 1% 5% 120%-150% Center positive receptacle 180mV pk-pk ME40A1803N01 18.0V 2.22A 40W 1% 5% 120%-150% 24.0V 1.70A 40W 240mV pk-pk 1% 120%-140% ME40A2403N01 5% 25W 100mV pk-pk 120%-150% ME40A0503Q01 5.0V 5.00A 1% 5% ME40A0903Q01 9.0V 4.00A 36W 100mV pk-pk 120%-150% 1% 5% 2.5 x 5.5 x 9.5mm Class II Desktop, 120mV pk-pk Straight barrel type, IEC60320 C18 ME40A1203Q01 12.0V 3.40A 40W 1% 5% 120%-150% Center positive receptacle 180mV pk-pk ME40A1803Q01 18.0V 2.22A 40W 1% 5% 120%-150% 240mV pk-pk ME40A2403Q01 24.0V 1.70A 40W 1% 5% 120%-140% 100mV pk-pk ME40A0503B01 5.0V 5.00A 25W 1% 5% 120%-150% 36W 100mV pk-pk 120%-150% ME40A0903B01 9.0V 4.00A 1% 5% 2.5 x 5.5 x 9.5mm Class II Wall-plug, ME40A1203B01 12.0V 3.40A 40W 120mV pk-pk 1% 5% 120%-150% Straight barrel type, Interchangeable Center positive blades 180mV pk-pk ME40A1803B01 18.0V 2.22A 40W 1% 5% 120%-150% 240mV pk-pk ME40A2403B01 24.0V 1.70A 40W 1% 5% 120%-140% ME40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 1 ME40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.40W Single Output External P40W Single Output External Powerower 40W Single Output External Power 40W Single Output External Power ME40 FME40 Familyamily ME40 Family ME40 Family Medical GrMedical Gradeade Medical Grade Medical Grade MODEL SELECTION Output Output Ripple & Line Load Overvoltage Output Cable Input Model Number Volts 1 Current Power Noise Regulation Regulation Trip Range & Connector Configuration 100mV pk-pk ME40A0503C01 5.0V 5.00A 25W 1% 5% 120%-150% 100mV pk-pk ME40A0903C01 9.0V 4.00A 36W 1% 5% 120%-150% 2.5 x 5.5 x 9.5mm Class II Wall-plug, 120mV pk-pk Straight barrel type, Fixed North ME40A1203C01 12.0V 3.40A 40W 1% 5% 120%-150% Center positive American blades ME40A1803C01 18.0V 2.22A 40W 180mV pk-pk 1% 5% 120%-150% 240mV pk-pk ME40A2403C01 24.0V 1.70A 40W 1% 5% 120%-140% Note: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. 2. Standard models are fitted with North American blades. Order blade kit KT-1027K for other blades (EU. UK, Australia). 3. For EU fixed blades, replace C in the model number with M, for UK blades, replace C with G, for Australia blades, replace C with H. 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (TE40B1203F01). INPUT OUTPUT AC Input 100-240VAC, 10%, 47-63Hz, 1 Hold-Up Time 20ms at full load, 100VAC input Less than 700ms 115VAC, Full load Input Current 115VAC: 1.2A, 230VAC: 01.6A Turn On Time 40W continuous - See models chart for specific 264VAC, cold start: will not exceed 40A Inrush Current Output Power voltage model ratings F1, F2: 2.0A, 250VAC fuses (line & neutral lines) Input Fuses Output Voltage See models chart on pg 1 provided on all models Ripple and Noise See models chart on pg 1 Input-GND: <500A 264VAC, 60Hz, NC Leakage Current 500s response time for return to within 0.5% of final Output-GND: <4mA 264VAC, 60Hz, NC value for any 50% load step over the range of 5% to Transient Response Efficiency >87%, Typical 100% of rated load, i/t< 0.2A/s. Max. voltage deviation is +/-3.5% No Load Input <0.1W per DoE efficiency level VI requirements Regulation See models chart on pg 1 Power Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. PROTECTION SAFETY Overtemperature Will shutdown upon an overtemperature condition Safety Standards EN/IEC/UL60601-1, 3rd edition Auto-recovery Protection Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks 130 to 180% of rating, Hiccup mode Overload Protection total. Non-operating: Half-sine waveform, impact Shock Short Circuit acceleration of 100G, Pulse duration of 6ms Hiccup mode, Auto recovery Protection Number of shocks: 3 for each of the three axis Overvoltage Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. Hiccup mode. See models chart for trip ranges Protection Safety Drop Test 1.4m from table top to wooden platform, 6 faces RELIABILITY Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. >1,000,000 hours, Full load, 110 & 220 VAC input, MTBF 25C amb., per Telcordia 332 Issue 6 ISOLATION SPECIFICATIONS >8 years life based on calculations at 115VAC/60Hz & E-Cap Life 230VAC/50Hz, Ambient 25C at 24 hrs per day, Input-Output: 2 MOPP 365 days/year, 6 power up cycles per day Input-Ground: 1 MOPP Isolation Output-Ground: 1 MOPP Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. Note: All specifications are typical at nominal input, full load, at 25C ambient unless noted. ME40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. ME40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 2 ME40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.