65W Single Output SLB65 Family Medical / Industrial Grade FEATURES AND BENEFITS Medical Small 2 X 3 x 1.2 Form Factor Approved To Ul/CSA/IEC/IEC62368-1 For 1U Applications 2 x MOPP Isolation 65W Convection Cooled Meets 4th Edition/Heavy Industrial EMC Universal Input 80-264VAC -20C To 70C Operating Temperature Range Approved to UL/CSA/IEC/IEC60601-1, 3rd. Ed. 3 Years Warranty MODEL SELECTION Output Current Total OVP Output Powe r Model Number Volts Convection Cooled Ripple & Noise* Regulation Threshold 0.5%RMS, SLB65S05x 5V 8.0A 40 Watts 2% 7.9 1.1V 1.5% pk-pk 0.5%RMS, SLB65S12x 12V 5.0A 60 Watts 2% 14.0 1.1V 1.5% pk-pk 0.5%RMS, SLB65S15x 15V 4.0A 2% 18.0 1.5V 65 Watts 1% pk-pk 0.5%RMS, SLB65S18x 18V 3.6A 2% 21V 3.0V 65 Watts 1% pk-pk 0.5%RMS, SLB65S24x 24V 2.71A 65 Watts 2% 28.0 4.0V 1% pk-pk 0.5%RMS, SLB65S48x 48V 1.35A 65 Watts 2% 55.0 4.0V 1% pk-pk Notes: Replace the at the end of the model number with for class II (ungrounded) input or replace with for class I (grounded) input. INPUT AC Input Voltage 80-264VAC, Single phase AC Input Current 115VAC: TBD 230VAC: 1.0A Inrush Current 85A maximum 25C Cold Start 264VAC Input Fuse 3.15A, 250VAC Fuse Provided on All Models <100uA Patient Leakage Current Earth Leakage Current <500uA 264VAC, 60Hz input, NC AC Input Frequency 47-63Hz SLB65 Datasheet v0521 Copyright 202 1 SL Power Electronics Corp. All rights reserved. Page 165W Single Output SLB65 Family Medical / Industrial Grade EFFICIENCY Model Number Typical Measured 25C SLB65S12x, S L B 6 5 S 1 5 x 89% 230VAC, Full load 86.5% 115VAC, Full load SLB65S18x 89% 230VAC, Full load 87% 115VAC, Full load SLB65S24x 89% 230VAC, Full load 87% 115VAC, Full load S L B 6 5 S 4 8 x 88% 230VAC, Full load 88% 115VAC, Full load OUTPUT Hold-up Time 12ms typical from loss of AC input at 115VAC Turn On Time <2 seconds 115VAC (<3s for 12V output) Output Power Max of 65 Watts for convection cooled 20 MHz Bandwidth, differential mode Measured with noise probe directly Ripple and Noise 0.5% RMS, 1%~1.5% pk-pk for all models across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors 500s typ. response time for return to within 0.5% of final value for a Transient Response Measured 25C 50% load change, i/t< 0.2A/s Max voltage deviation is 3.5% Minimum Load No minimum load is required Total regulation is the maximum Total Regulation 2% for all models deviation from nominal voltage for all loading conditions Cooling Convection (65W Output) 5% overshoot at turn-on, 5% overshoot at turn-off, under all Overshoot conditions ENVIRONMENT Operating Temperature -20C to +70C Temperature Derating 40% derating at 70C Cooling Convection Storage Temperature -40C to +85C Operating: 500 to 5,000 meters Altitude Non-operating: 500 to 40,000 ft Relative Humidity 5% to 95%, Non-condensing Shock Non-operating: Half-sine, 40 gpk, 10ms, 3 axes, 6 shocks total Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, Vibration 1 hr in each of three axes SLB65 Datasheet v0521 Copyright 202 1 SL Power Electronics Corp. All rights reserved. Page 2