60W Single Output SLE60PD Family Medical / Industrial Grade FEATURES AND BENEFITS CoC V5 Tier 2(2016) USB-C with Power Delivery Output 0.15W Standby Power Medical & ITE Safety Approvals 2 x MOPP Input to Output Isolation 5V, 9V, 12V, 15V, 20V Outputs, Up to 60W Suitable for Medical Equipment Up to Class BF 5,000m Operating Altitude AC Inlet IEC60320 C8 (c. II) Low Leakage Current 100A Interchangeable plugs (c.II) DOE Efficiency Level VI MODEL SELECTION Rated Ripple & Voltage Line & Load Model Number Volts Current Input Configuration Start Up Delay Power Tolerance Regulation Noise Class II Desktop, 150mV Line: 2% SLE60SPD9 6N01 5, 9, 12, 15, 20 V 3A 60W 5% 3s IEC60320 C8 Receptacle pk-pk Load: 5% Class II Interchangeable 150mV Line: 2% 5, 9, 12, 15, 20 V SLE60SPD96B01 3A 60W 5% 3s Blades (Sold Separately) pk-pk Load: 5% Notes: 1. N in the model number (SLE60SPD99N01) indicates IEC60320 C8 inlet (class II). 2. Power supply is not provided with a line cord. 3. Power supply is not provided with a USB-C cable. 4. Power supplies are not medical equipment (applied parts), medical product manufacturers shall take responsibility for further evaluation of class B/BF/CF compliance of their end product. INPUT SAFETY rrCEdUUeatoLLquiri66meti20donp 36ael6i0pp,me 81As -e-1ml1winc-11tiatts, h 3ioBrd nF Input Voltage Frequency 90VAC264VAC - 47Hz63Hz Medical: IEC60601-1, ANSI/AAMI ES60601-1 ITE: CB IEC62638-1, UL62638-1 Input Current 1.3A at 90VAC Medical: CAN/CSA C22.2 NO. 60601-1 ITE: CAN/ Inrush Current 100A max at 240VAC cold start UL CSA C22.2 NO. 62638-1 Touch Leakage Current 100A at 264VAC TUV Medical: EN60601-1 ITE: EN62638-1 SLE60 Datasheet v0221 Copyright 2021 SL Power Electronics Corp. All rights reserved. Page 160W Single Output SLE60PD Family Medical / Industrial Grade PROTECTION EMI/EMC COMPLIANCE Medical: IEC/EN 60601-1-2, CISPR 11 ITE: 120%200% rated output power, Au- Conducted Emissions Overload Protection EN55032 Class B, CISPR 22 to-recovery Medical: IEC/EN 60601-1-2, CISPR 11 ITE: 120%200% rated output voltage input Radiated Emissions Overvoltage Protection EN55032 Class B, CISPR 22 to reset Medical: IEC/EN 60601-1-2 ITE: EN55024, Short circuit Protection Trip and restart - Hiccup Mode Immunity CISPR 24 Electro-Static ISOLATION Discharge (ESD) EN61000-4-2, 15kV air, 8kV contact Immunity on Power Ports Isolation Safety Rating 4,000VAC Input to Output (2 x MOPP) Radiated RF EM Fields EN61000-4-3, 10V/m, 3V/m Susceptibility3 (80MHz2.7GMHz) ENVIROMENT Electrical Fast Transients EN61000-4-4, 2kV on AC port, 1kV on (EFT)/Bursts signal ports Operating Temperature 0C to 40C Surges, Line to Line (DM) EN61000-4-5, 2kV line to ground, 1kV Storage Temperature -20C to 70C and Line to Ground (CM) line to line (diff mode) Desktop - 185g / Wall Plug - 205g Weight EN61000-4-6, 3Vrms, 6Vrms (0.15MHz Conducted RF Immunity Dimensions 51.5mm x 88.0mm x 28.0mm 80MHz) Operating Humidity 5% RH to 95% RH, non-condensing Power Frequency EN61000-4-8, 30A/m Storage Humidity 5% RH to 95% RH Magnetic Field Immunity Voltage Dip Immunity EN61000-4-11, 0%, 70%, 0% of UT Operating Altitude 5,000m Harmonic Current Dielectric Withstand 4,000 VAC input to output EN61000-3-2, Class A Voltage Emissions Insulation Resistance 10M Ohms, 500VDC input to output Flicker Test EN61000-3-3 PACKAGING RELIABILITY Desktop : 16.8Kg Box - 80/carton MTBF >100,000 hours MIL-HDBK-217 at 25C Weight, Packing Qty Wall plug: 14.3Kg Box - 60/Carton OUTLINE DRAWING DC Cable Connector USB-C Disclaimer: The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. SLE60 Datasheet v0221 Copyright 2021 SL Power Electronics Corp. All rights reserved. Page 2