TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 30W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy Industrial Levels of EN61000 EMC Requirements Meets EN55032/CISPR22 and FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin nd Approved to EN/IEC/UL60950-1, 2 Ed., Am. 2 E-cap life of >8 years >1,000,000 hours MTBF 3 Year Warranty Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE30A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, PLUS Heavy Industrial levels of various EN61000-4-x standards for EMC. Model Selection Model Output Output Ripple & Line Load Output Input Connector Configuration Number Volts Current Power Noise Regulation Regulation TE30A0503F01 5.0V 4.00A 20W 75mV pk-pk 1% 5% TE30A0903F01 9.0V 3.00A 27W 90mV pk-pk 1% 5% TE30A1203F01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 2.5 x 5.5 x 9.5mm Class I Desktop, TE30A1503F01 15.0V 2.00A 30W 150mV pk-pk 1% 5% Straight Barrel Type, IEC60320 C14 TE30A1803F01 18.0V 1.67A 30W 180mV pk-pk 1% 5% center positive Receptacle TE30A2403F01 24.0V 1.33A 30W 240mV pk-pk 1% 5% TE30A4803F01 48.0V 0.63A 30W 480mV pk-pk 1% 5% TE30A0503N01 5.0V 4.00A 20W 75mV pk-pk 1% 5% TE30A0903N01 9.0V 3.00A 27W 90mV pk-pk 1% 5% TE30A1203N01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 2.5 x 5.5 x 9.5mm Class II Desktop, TE30A1503N01 15.0V 2.00A 30W 150mV pk-pk 1% 5% Straight Barrel Type, IEC60320 C8 TE30A1803N01 18.0V 1.67A 30W 180mV pk-pk 1% 5% center positive Receptacle TE30A2403N01 24.0V 1.33A 30W 240mV pk-pk 1% 5% TE30A4803N01 48.0V 0.63A 30W 480mV pk-pk 1% 5% TE30A0503Q01 5.0V 4.00A 20W 75mV pk-pk 1% 5% TE30A0903Q01 9.0V 3.00A 27W 90mV pk-pk 1% 5% TE30A1203Q01 12.0V 2.50A 30W 120mV pk-pk 2.5 x 5.5 x 9.5mm Class II Desktop, 1% 5% TE30A1503Q01 15.0V 2.00A 30W 150mV pk-pk 1% 5% Straight Barrel Type, IEC60320 C18 TE30A1803Q01 18.0V 1.67A 30W 180mV pk-pk 1% 5% center positive Receptacle TE30A2403Q01 24.0V 1.33A 30W 240mV pk-pk 1% 5% TE30A4803Q01 48.0V 0.63A 30W 480mV pk-pk 1% 5% TE30A0503B01 5.0V 4.00A 20W 75mV pk-pk 1% 5% TE30A0903B01 9.0V 3.00A 27W 90mV pk-pk 1% 5% Class II Wall-Plug, TE30A1203B01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 2.5 x 5.5 x 9.5mm Interchangeable TE30A1503B01 15.0V 2.00A 30W 150mV pk-pk 1% 5% Straight Barrel Type, Blades (North TE30A1803B01 18.0V 1.67A 30W 180mV pk-pk 1% 5% center positive American Blade included) TE30A2403B01 24.0V 1.33A 30W 240mV pk-pk 1% 5% TE30A4803B01 48.0V 0.63A 30W 480mV pk-pk 1% 5% TE30A0503C01 5.0V 4.00A 20W 75mV pk-pk 1% 5% TE30A0903C01 9.0V 3.00A 27W 90mV pk-pk 1% 5% TE30A1203C01 12.0V 2.50A 30W 120mV pk-pk 1% 5% 2.5 x 5.5 x 9.5mm Class II Wall-Plug, TE30A1503C01 15.0V 2.00A 30W 150mV pk-pk 1% 5% Straight Barrel Type, Fixed North TE30A1803C01 18.0V 1.67A 30W 180mV pk-pk 1% 5% center positive American Blades TE30A2403C01 24.0V 1.33A 30W 240mV pk-pk 1% 5% TE30A4803C01 48.0V 0.63A 30W 480mV pk-pk 1% 5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1F ceramic and 47F low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace C in the model number with M, for UK blades, replace C with G, for Australia blades, replace C with H. 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (TE30B1203F01). www.slpower.com TE30 Rev 1.8 5-JAN-17 1TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series General Specifications Less than 700mS 115Vac, full load AC Input 100-240Vac, 10%, 47-63Hz, 1 Turn On Time Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an overtemperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection Input Fuse 2.0A, 250Vac Overload Protection 130 to 180% of rating, Hiccup Mode Earth Leakage Input-GND: <500A 264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Current Output-GND: <4mA 264Vac, 60Hz, NC Protection Overvoltage Meets US DoE Efficiency Level VI Average Hiccup Mode. See model chart above for Efficiency efficiency levels trip ranges. Protection Input-Output: 4000Vac 20 to 30W continuous See models chart for Output Power Isolation Input-Ground: 1500Vac specific voltage model ratings. Output-Ground: 1500Vac No Load Input <0.1W per DoE Efficiency Level VI Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Requirements Power -20C to +70C Operating Ripple and Noise See models chart on pg 1. Start Up at -40C, full load, (warmup period before Temperature all parameters are within published specifications). Temperature Output Voltage See models chart on pg 1. See Derating Charts below. Derating 500 s response time for return to within 0.5% Transient of final value for any 50% load step over the -40C to +85C Storage Temperature range of 5% to 100% of rated load, i/ t< Response 0.2A/ s. Max. voltage deviation is +/-3.5%. Operating: to 5000m. Regulation See models chart on pg 1. Altitude Non-operating: -500 to 40,000 ft. 1.4m from table top to wooden platform, 4 5% to 95%, non-condensing Drop Test Relative Humidity faces. Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of 10 three axis sweeps / axes, 3 axes >1,000,000 hours, full load, 110 & 220Vac Dimensions See outline drawings MTBF input, 25C amb., per Telcordia 332 Issue 6. >8 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25C Weight 250g E-Cap Life at 24 hrs per day, 365 days/year, 6 power up cycles per day. All specifications are typical at nominal input, full load, at 25C ambient unless noted. www.slpower.com TE30 Rev 1.8 5-JAN-17 2