TF3000A400K 3000W Single Output TF3000HV Family Industrial Grade FEATURES AND BENEFITS 3000W Fan-Cooled (Load & Temp. Controlled) Remote Setting Multi PSU via RS232,RS485 & IC Programmable Output Voltage (0% ~ 105%) Power OK Signal Programmable Output Current (0% ~ 105%) Remote ON/OFF, Remote Sense Function Forced Current Sharing at Parallel Operation Protection: OVP, OLP, OTP, Fan Failure Constant Current Limit 3 Year Warranty Selectable +5V/0.5A or +9V/0.3A Aux Output Global Control via RS232 MODEL SELECTION Output Rated Current Output Ripple & Line Load Voltage 4 Model Number Efficiency 1 3 Volts Current Range Power Noise Regulation Regulation Tolerance TF3000A150K 150V 20A 0-20A 3000W 1500mV pk-pk 1% 1% 2% 93% TF3000A200K 200V 15A 0-15A 3000W 2000mV pk-pk 1% 1% 2% 93% TF3000A250K 250V 12A 0-12A 3000W 2500mV pk-pk 1% 1% 2% 93% TF3000A300K 300V 10A 0-10A 3000W 3000mV pk-pk 1% 1% 2% 93% 400V 7.5A 0-7.5A 3000W 4000mV pk-pk 1% 1% 2% 93% 1. De-rating may apply in low input voltage. Check the derating curve for details 4. Tolerance: includes setup time tolerance, line regulation and load regulation. Notes : 5. Other output voltages available, consult factory. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted 6. All specifications are typical at 230Vac, full load, at 25C ambient unless noted. pair-wire terminated with a 0.1uF & 47uF parallel capacitor. INPUT OUTPUT Output Voltage See Model Selection Table on pg 1 Input Voltage and 100-240Vac, 10%, 47-63Hz, 1127-370Vdc 1 Frequency 3000W continuous See model selection 1 115Vac: 19.7A (2000W output) Output Power table for specific voltage model ratings Input Current 230Vac: 14.5A (3000W output) Voltage Range 5.0% Typical adjustment by potentiometer (VR1) Inrush Current 33A/115VAC, 65A/230VAC Voltage Tolerance See Model Selection Table on pg 1 Efficiency See Model Selection Table Hold-Up Time 14ms/230VAC at full load Power Factor 0.95/230VAC, 0.98/115VAC at full load 1100ms Turn On Time Leakage Current < 3.5mA/240VAC 300ms at full load Rise Time Ripple and Noise See Model Selection Table on pg 1 De-rating may apply in low input voltage. Please check the de-rating Notes : 1. curve for more details Line/Load Regulation See Model Selection Table on pg 1 De-rating may apply in low input voltage. Please check the de-rating Notes : 1. curve for more details CONNECTOR INFORMATION Input Connector Output Connector Signal Connector Term. 1) AC LINE Pinout: Term. 2) NEUTRAL + and - See Signal Connector Table on pg 3 Term. 3) GROUND Connector: JST PHDR-24VS or equivalent Mating Connector 10 wire lugs 1/4-20 Wire Lugs /terminal: Pins: JST SPHD-002T-P0.5 or equivalent TF3000HV Datasheet v0321 Copyright 2021 SL Power Electronics Corp. All rights reserved. Page 13000W Single Output TF3000HV Family Industrial Grade EMI/EMC COMPLIANCE AUXILIARY SIGNALS Conducted Emissions Certified EN 55022 EN 61204-3 EN 61000-6-3 Selectable +5V/0.5A or +9V/0.3A auxiliary Auxiliary Power output Radiated Emissions Certified EN 55022 EN 61204-3 EN 61000-6-3 Remote ON / OFF Electro-Static Discharge By external switch Control (ESD) Immunity on Power EN55024/IEC61000-4-2 ports Open drain signal low when PSU turns on, Max. Power OK Signal Radiated RF EM Fields sink current: 20mA, Max. drain voltage: 40V EN55022/EN61000-4-3 Susceptibility Adjustment of output voltage is between Output Voltage Trim 0 ~ 105% of rated output Electrical Fast EN55024/IEC61000-4-4 Transients (EFT) /Bursts Adjustment of output current is between Output Current Trim 0 ~ 105% of rated output Surges, Line to Line EN55024/IEC61000-4-5 (Diff Mode) and Line to GND (CMN Mode) Please refer to Current Sharing with Remote 1 Parallel (Current Sharing) Sensing (Parallel Connection) Diagram Conducted Disturbances EN55022/IEC61000-4-6 induced by RF Fields Notes : 1. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power. Rated Power frequency EN55024/IEC1000-4-8 magnetic fields PROTECTION Voltage Interruptions, EN55024/IECEN61000-4-11 Dips, Sags & Surges Variable OVP Refer to VCI VS OVP curve.(OVP Harmonic Current EN61000-3-2 Overvoltage Protection Tolerance 7%), Latch Type (Recovery after Emissions reset AC power ON or inhibit). Flicker Test EN61000-3-3 Short Circuit Protection Constant current, auto-recovery Notes : 1. The power supply is considered a component which will be installed into Overtemperature a final equipment. The final equipment must be re-confirmed that it still 855C measured on NTC. Auto recovery Protection meets EMC directives. Overload Protection 105% of rated power, constant current type SAFETY Safety Certifications UL62368-1, EN62368-1 ISOLATION SPECIFICATIONS Input-Output: 3000Vac 1 Input-Ground: 1500Vac Isolation 1 Isolation Output-Ground: 500Vac RELIABILITY Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC MTBF >112,000 hours per MIL-HDBK-217F Notes : 1. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC ENVIRONMENT Operating Temperature -25 ~ +60C (Refer to load de-rating curve) Temperature Derating See Derating Curve Vibration 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64 Dimensions 170 x 64 x 280mm 6.69 x 2.5 x 11.02 inch Cooling Load and temperature control fan Relative Humidity 20% to 90%, non-condensing Storage Temperature and Humidity -40 ~ +85C, 10 ~ 95% RH Weight & Packing 2.6kg 6pcs/carton, 16.6kg/1.86CUFT TF3000HV Datasheet v0321 Copyright 2021 SL Power Electronics Corp. All rights reserved. Page 2