Air Combination Filter Regulator + Lubricator JIS Symbol AC10A to AC60A Filter Regulator Lubricator How to Order Option/Semi-standard: Select one each for a to l. AC 30 A 03 DE Option/Attachment/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30A-F03DE1-KSV-136NR Symbol Description Body size 10 20 30 40 50 60 Metric thread (M5) Nil Rc Thread type Note 1) N NPT Note 2) F G + M5 M5 01 1/8 02 1/4 03 Port size 3/8 04 1/2 06 3/4 10 1 + Nil Without auto drain Float type a C Float type auto drain (N.C.) auto drain D Float type auto drain (N.O.) + Nil Without pressure gauge Note 3) E Square embedded type pressure gauge (with limit indicator) Pressure Round type pressure gauge (without limit indicator) gauge G Round type pressure gauge (with limit indicator) b M Round type pressure gauge (with color zone) E1 Output: NPN output / Electrical entry: Wiring bottom entry Digital E2 Output: NPN output / Electrical entry: Wiring top entry pressure E3 Output: PNP output / Electrical entry: Wiring bottom entry switch E4 Output: PNP output / Electrical entry: Wiring top entry + Nil Without attachment c Check valve Note 4) K Mounting position: AW+K+AL + Nil Without attachment Pressure d Note 5) switch S Mounting position: AW+S+AL + 3-port valve for Nil Without attachment e residual pressure V Mounting position: AW+AL+V release + Nil 0.05 to 0.85 MPa setting f Set pressure Note 6) 1 0.02 to 0.2 MPa setting + Nil Polycarbonate bowl 2 Metal bowl 6 Nylon bowl Note 7) g Bowl 8 Metal bowl with level gauge C With bowl guard 6C Nylon bowl with bowl guard + Nil With drain cock Filter regulator Drain guide 1/8 Note 9) h J Note 8) drain port Drain guide 1/4 Note 10) W Drain cock with barb fitting: For 6 x 4 nylon tube 306 Semi-standard Attachment OptionAir Combination Series AC10A to AC60A AC20A AC40A Symbol Description Body size 10 20 30 40 50 60 Lubricator Nil Without drain cock i lubricant 3 Lubricator with drain cock exhaust port + Nil Relieving type Exhaust j mechanism N Non-relieving type + Nil Flow direction: Left to right k Flow direction R Flow direction: Right to left + Nil Name plate and pressure gauge in imperial units: MPa Note 11) Note 13) Note 13) Note 13) Note 13) Note 13) Note 13) l Pressure unit Z Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, F Note 12) Note 14) Note 14) Note 14) Note 14) Note 14) ZA Digital pressure switch: With unit conversion function Note 1) Drain guide is NPT1/8 (applicable to the AC20A) Note 6) The only difference from the standard Note 11) For thread type: M5 and NPT. This product is for and NPT1/4 (applicable to the AC30A to AC60A). specifications is the adjusting spring for the overseas use only according to the new The auto drain port comes with 3/8 one-touch regulator. It does not restrict the setting of 0.2 Measurement Law. (The SI unit type is provided fitting (applicable to the AC30A to AC60A). MPa or more. When the pressure gauge is for use in Japan.) The digital pressure switch will Note 2) Drain guide is G1/8 (applicable to the AC20A) attached, a 0.2 MPa pressure gauge will be fitted. be equipped with the unit conversion function, setting to psi initially. and G1/4 (applicable to the AC30A to AC60A). Note 7) Refer to Chemical Data on page 287 when Note 3) Option G, M are not assembled and supplied selecting a case material. MPa and psi are shown together on the pressure unit. loose at the time of shipment. Note 8) Float type auto drain: The combination of C and D Note 12) For options: E1, E2, E3, E4. This product is for Note 4) Not available with piping port size: 06. is not possible. overseas use only according to the new Note 5) The bracket position varies depending on the Note 9) Without a valve function Measurement Law. (The SI unit is provided for pressure switch mounting. Note 10) Metal bowl: The combination of 2 and 8 is not use in Japan.) possible. Note 13) : For thread type: M5 and NPT only Note 14) : Select with options: E1, E2, E3, E4. Standard Specifications Model AC10A AC20A AC30A AC40A AC40A-06 AC50A AC60A Filter regulator AW10 AW20 AW30 AW40 AW40-06 AW60 AW60 Component Lubricator AL10 AL20 AL30 AL40 AL40-06 AL50 AL60 Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Note 1) Pressure gauge port size 1/16 1/8 1/4 Fluid Air Note 2) Ambient and fluid temperature 5 to 60C (with no freezing) AC Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa AF Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa Note 3) AR Relief pressure Set pressure + 0.05 MPa at relief flow rate of 0.1 l/min (ANR) Nominal filtration rating 5 m AL Recommended lubricant Class 1 turbine oil (ISO VG32) Bowl material Polycarbonate AW Bowl guard Semi-standard Standard A G Regulator construction Relieving type Mass (kg) 0.20 0.59 0.75 1.41 1.46 3.33 3.40 AV Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC20A to AC60A). AF800 Note 2) 5 to 50C for the products with the digital pressure switch AF900 Note 3) Not applicable to the AC10A. 307 Semi-standard