GLQ110 Series Installation & Operating Instructions Installation & Safety Output Ratings To comply with the published safety standards, the following must be observed when Convection Cooling 30 CFM Forced Air Cooling Output Voltage using this power supply: Model Max. Output Max. Output Max. Output Max. Output (V) Current (A) Power (W) Current (A) Power (W) 1. Maximum ambient temperature for the power supply must not exceed 50C. +5 9.0 11.0 +12 4.5 5 2. When installing the power supply in the end-use equipment, special attention GLQ112 -12 0.7 1.0 is required to ensure safety compliance with the following safety standards: 5 to 25 2.5 3.0 UL60950, EN60950-1, IEC60950-1, and CSA22.2 No. 234-M90 including the +5 9.0 11.0 requirements for creepage distances, clearances, and distance through insulation +15 4.5 5.0 between primary wiring and earth or secondary (SELV) wiring. GLQ113 80 110 -15 0.7 1.0 5 to 25 2.5 3.0 3. The power supplys rated input voltage is automatically selected. Please refer to +5 9.0 11.0 the specification sheet for the input voltage range. +12 4.5 5.0 GLQ114 4. The maximum output power of the supply must not exceed the rating indicated in -12 0.7 1.0 the specification sheet. +24 3.5 4.5 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Connector PIN Designation 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply Input Connector PIN GLQ112 GLQ113 GLQ114 before servicing. 1 GND SK1 3 Neutral 7. When operating with a dc input voltage range, the unit input must be protected by 5 Line a dc rated fuse in the end-use installation system. Output Connector PIN GLQ112 GLQ113 GLQ114 8. The internal fuse should only be replaced with a 4 A, 250 V ac, Type SP0001.1010 1 manufactured by Schurter AG, Type 216004 manufactured by Littelfuse or Type 2 +5 V S501 manufactured by Cooper. 3 4 9. This power supply is marked following the provisions of the Low Voltage 5 Common Directive, 2006/95/EC. 6 SK2 7 For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or 8 +12 V +15 V +12 V send an e-mail to tech solahd.com. Please visit our Web site at www.solahd.com for 9 +12 V +15 V +12 V additional product information and specification sheets. 10 -12 V -15 V -12 V 11 +5 V to +25 V +5 V to +25 V +24 V 12 -5 V to -25 V -5 V to -25 V Common 1 +Sense SK201 2 -Sense 1 P OK SK202 2 GND P/N: A272-168 Rev 2 12/29/09 Ref: 033610016025 V O/P ADJ GLQ110 Series Installation & Operating Instructions Mechanical Outline Mechanical Dimensions .25 6.35 SK201 SK202 1 4.28 4.00 SK2 108.6 101.6 2.50 5 ~ 25 V 3.50 O/P ADJ 63.5 88.9 12 1 3 SK1 5 6.40 162.6 6.50 165.1 .25 6.35 7.30 185.5 7.00 177.8 Bottom View with Optional L-Bracket Top View 2.20 56.0 .86 21.8 5.90 150.0 Side View with Optional L-Bracket All dimensions are in inches mm Screw size: 6-32 GLQ112, GLQ113, and GLQ114 are commercial designations of model numbers LPQ112, LPQ113, and LPQ114 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice.