Power Supplies 4 GL Series: Single & Multi Output Switchers Cover and Bracket Options Cover options can be ordered separately. They are designed to simply mechanical integration of the power supplies into systems and add an extra measure of electrical safety for service personnel. Bracket kits can be ordered separately for GL110 series only. It is needed when the cover option is used. Catalog Number Description Enclosure kit for the GL20 and GL40 UL 60950 GLX40 EN 60950 Enclosure kit for the GL50 GLX50 Enclosure kit for the GL60 GLX60 The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to Enclosure kit for the GL80 GLX80 500 watts for use in various industrial and medical applica- Bracket kit for the GL110 GLX110-B tions requiring standard footprint size and very high reliability. Cover kit for the GL110 GLX110-C Enclosure kit for the GL120 These low-pro le AC/DC switchers offer universal input GLX120 voltage with no switches or jumpers, ideal for higher volume Cover kit for the GLQ140 GLX140-C worldwide applications. Cover with top fan kit for the GLQ140 GLX140-CF Cover kit for the GL150 GLX150-C All models feature: Cover kit for the quad output GL170 GLX17Q-C Industry standard footprints Cover kit for the single output GL170 GLX17S-C Universal input Cover end fan kit for the GL250 GLX250-CEF Full power to 50C Cover with top fan kit for the GL250/350 GLX250-CF High demonstrated MTBF (Table 1) Automatic overvoltage protection Overload protection Mating Connectors Built-in EMI Filtering Can be ordered separately for units with Molex Extensive safety approvals connection Derated operation to 70C Kits include mating housing and pins for input and output 250 VA and higher VA size enclosed connection Two year limited warranty Catalog Number Description Many models feature: GLX40, GLX50 and GLX60 Mating Connector Kit 70-841-006 EN61000-3-2 Compliance GLS110 Mating Connector Kit 70-841-007 Supervisory outputs (5 V/12 V) GLQ110 Mating Connector Kit 70-841-008 th Wide-adjustable oating 4 output GLS120 Mating Connector Kit 70-841-020 Single wire current share GLQ123 Mating Connector Kit 70-841-012 Medical approvals GLQ142 Mating Connector Kit 70-841-017 Remote Sense GLS150 Mating Connector Kit 70-841-009 Adjustable main output Power Fail and DC Good signals GLQ150 Mating Connector Kit 70-841-010 Wide-adjustable on single output models GLQ170 Mating Connector Kit 70-841-015 GLS170 Mating Connector Kit 70-841-016 GLX250 Mating Connector Kit 70-841-005 GLS500 Mating Connector Kit 70-841-024 (Table 2) Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 141Power Supplies 4 Specifications GLQ120, GL250, GL20, GL40 GL50 GL60, GL110 GL140 GL150 GL170 GL500 GLS120 GL350 Input 85 - 132 Vac 85 - 264 Vac 90 - 264 Vac 85 - 264 Vac or 170 - 264 Vac Input 85 - 264 Vac 120 - 300 Vdc 85 - 264 Vac (1) 120 - 300 Vdc 127 - 300 Vdc 120 - 300 Vdc auto-selected. Voltage 220 - 300 Vdc 47-63 Hz , 400 40 Hz 47-63 Hz Frequency GL20: <15A peak GL250: GLQ120: 115 Vac <30A 20 A max., <18A peak 38 A max., cold peak 230 Vac, cold start 115 Vac, <60A peak start 25C 50 A max., cold start 25C. 25C. Inrush <36 A peak 230 Vac, 38 A max, cold start 25C cold start 230 Vac, Current GL40: <18A peak GL350: cold start 25C GLS120: 25C cold start 115 Vac <36A 38 A max., 40A max., cold 25C peak 230 Vac, cold start start 25C cold start 25C 25C. GLQ120: 65% 80% - 85% typical at full 85% typical 70% typical 70% typical typical load. GLS120: 75% typical at full load at full load, Efficiency at full load at full load at full load 80% typical at nominal line full load FCC Class B CISPR 22 Class B EN55022 Class B EMI/RFI Non-medical: <0.5mA GLQ120: Non-Medical: Medical: 275 A Non-Medical: <1 mA Non-Medical: Non-Medical: 0.1 mA Safety 50/60 Hz <0.5 mA 50/60 Hz, <0.5 mA <0.5 mA 1.0 mA <0.5 mA Medical: <0.5 mA Ground 264 Vac input for Medical: 264 Vac input. Medical: Medical: < 75 A 50/60 Hz, 50/60 Hz, < 250 A 50/60 Hz, Class I <0.25mA < 75A GLS120: <0.3mA Leakage 50/60 Hz, 264 Vac input 264 Vac input 1.0 mA 264 Vac input 50/60 Hz 50/60 Hz 0.5mA 50/60 Hz, Current 264 Vac input 50/60 Hz, 264 Vac input for 264 Vac input 50/60 Hz, 264 Vac input 264 Vac input Class II (for single 264 Vac input output only) Output Refer to the selection table Power 3.3 - 5.5V on GL60: -5, main -12 - +10% minimum 5% minimum Adjustment 20% minimum for 2:1 wide -5, +10% 15V on 3rd GL110: 5% on main, 5-25 V single output only 5% minimum ratio 2:1 wide ratio 5% Range on minimum output 3.3 - on main, 5-25 V th models minimum on 4 output Main Output 25 V on 4th th on 4 output output 20 ms full load, 10/20 ms 115/230 Hold-up 20 ms full load, 115 Vac nominal line 115 Vac nominal line Vac Input line Time Short circuit protection on all outputs. Primary overload protection Overload 5 V output: 5.7 5 V output: 5.7 5 V output 5.7 to 5 V output 5.7 3.3 V and 5 V to 6.7 Vdc. 10% to 40% to 6.7 Vdc. 20-35% 6.7 Vdc. Other - 6.7 Vdc. Other output: 20% to Tracks out- Overvoltage 30-50% above Other out- above Other outputs above outputs 10% to outputs 10% 35% puts 1, 3 & 4 nominal output puts10% to 25% nominal 10% to 25% nominal Protection 25% above to 25% above above nominal 10 to 35% above nominal output above output nominal output nominal output output output nominal output Compensates for 0.5 V lead drop minimum Will operate without remote sense connected, Reverse connection protected Remote Sense General (2) Storage: -40C to +85C Operating: 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C start up. Temperature Electro- Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4 -2, -3, -4, -5, -6, -8, -11 Level 3 magnetic Susceptibility Operating non-condensing up to 95% RH Humidity Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz Vibration (2 G peak 8 Hz to 500 Hz for GL500) >550,000 hours demonstrated at full load and 25C ambient conditions MTBF Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certi cate and report CE Mark (LVD) Safety Medical: UL 2601 CSA 22.2 No. 601.1 EN 60601-1 Notes: (1) Proper circuit protection required when operating with a DC input voltage. (2) Regulation and ripple may deviate from the spec at -20C start up. Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 142