Uninterruptible Power Supplies S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS The new SolaHD S4K4U6000C and the S4K6U10KC Industrial UPS Series are the first true On-Line industrial UPS that provide higher output power factor, higher efficiency, flexible output voltage, an integrated maintenance bypass switch and internal batteries all in slim 4U (7.0) and 6U (10.5 ) enclosures respectively. The S4K4UC and S4K6UC features true On-Line (double conversion) topology providing the ultimate in protection against a wide range of potential power problems. The S4K4UC design of two 3 kVA, 120V inverters allow flexible output voltage to meet mixed load voltage requirements. The UPS automatically configures the output voltage to match the input configuration without requiring tap selections. Self ENPC diagnostics simplify maintenance and troubleshooting. The E179213 standard maintenance bypass switch provides an additional Automatic frequency detection (60 or 50 Hz) level of protection. Power factor correction The S4K4UC and S4K6UC also feature a wide input voltage Self-diagnostics simplify maintenance and window to support the critical load without having to transfer troubleshooting to the battery. This extends system availability when back-up Remote emergency Power Off (REPO) is truly needed. TM Intellislot USB and terminal block communication ports Compatible with most standby generators Applications Uses an average of 35% less energy than their standard Industrial Computers counterparts Robotics and Process Controls Provides continuous uptime for the connected equip- Industrial Automation Systems ment, with capacity and battery back-up delivered in Network Servers cabinets that use 4U to 6U of rack space Enterprise Telecommunication Systems Two year limited warranty Printing and Publishing Machinery Pharmaceutical and Medical Diagnosis Equipment Certifications and Compliances Industrial and Commercial Machinery Listed, UPS Equipment Micro-processor Controlled Equipment - UL 1778 Mission Critical Devices - CSA C22.2 No. 107.3 IEEE/ANSI C62.41 Category A & B Features ISTA Procedure 1A True double conversion topology ABS Type Approved Higher power factor of 0.80 (6kVA) and 0.90 (10kVA) RoHS Compliant Both models offer 208/120V or 240/120V ENERGY STAR certified Configurable as a tower or rack mounting Highest density, 6 kVA in only 4U and 10 kVA in only 6U of rack space Related Products Easily installed in 18 to 32 deep rack using rack Portable MCR Power Conditioners mount kit SRS1832 Surge Protective Devices User replaceable, hot-swappable internal battery module Active Tracking Filters Extended battery cabinets Includes both automatic and manual maintenance bypass switch Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 86 March 2017Uninterruptible Power Supplies S4K 6 and 10 kVA Specifications Table 1: UPS Specifications Model Number Parameters S4K4U6000C S4K6U10KC 4800 W/6000 VA 9000 W/10000 VA Rating Dimensions, W x D x h, in. (mm) 10.30 x 26.50 x 16.90 6.80 x 26.10 x 16.90 (173.0 x 662.0 x 430.0) Unit (261.0 x 672.0 x 430.0) 16.70 x 32.80 x 24.10 13.20 x 33.10 x 26.10 (336.0 x 842.0 x 662.0) Shipping (424.0 x 832.0 x 612.0) Weight, lbs. (kg) Unit 56.2 (25.50) 78.3 (35.50) 70.5 (32.00) 92.6 (42.00) Shipping Input AC Parameters 50 or 60 Hz (Factory default is 60 Hz) Nominal Operating Frequency 120/208 Vac 120 Factory Default Vac 120C L1L2 Factory Default Input Phase Angle 120, 180, 240 degrees auto-sensing on application of alternating current Allowable Input Phase Angle (Restrictions for LN voltage other than 120 Vac) 120 Vac nominal Factory Default L1N, L2N Vac 100/110/115/120/127 Vac (Can be modified with configuration program) User Configurable L1N, L2N Vac 4070 Hz Input Frequency w/o Battery Operation Hardwire terminal block 3W + G (LLNG) Input Power Connection 150 Vac L1N, L2N Maximum Allowable Vac Output AC Parameters 120/208 Vac 120C Factory Default Vac 120C L1L2 Factory Default Output Phase Angle 120, 180, 240 degrees auto-sensing on initial application of input alternating current Allowable Output Phase Angle 120 Vac nominal Factory Default L1N, L2N Vac 100/110/115/120/127 Vac, 2% User Configurable L1N, L2N Vac L1-N, L2-N Overload Rating 1 minute 105% to 130% 10 seconds 131% to 150% 1 second 151% to 200% At least 5 cycles >200% (impact load) Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 87 March 2017