Power Supplies 3 SDP Low Power DIN Rail Series The compact, lightweight DIN Rail power supplies come in output voltages from 5 to 48 Vdc and power ratings of up to 100 Watts. These extra small, efficient units are designed specifically for the industrial environment. Each unit is rated from -10C to 70C, with no derating necessary until above 60C. Many extra industrial features are standard for the TM SDP PowerBoost overload circuitry can start up industrial loads (i.e. motors, relays, solenoids and DC-DC converters), that can cause ordinary power supplies to E137632 foldback or shutdown. Each unit contains a DC indicator E61379 E234790 and front panel adjustment potentiometer. With the SolaHD Three year limited warranty SDP series, you can count on a high grade design. NEC Class 2 power supply acc. to NFPA 70 article 725-41 (a)(2) except Model SDP 4-24-100RT Applications Industrial Control Certifications and Compliances Process Control Listed, Industrial Control Equipment, E61379 Machine Control - UL 508, CSA C22.2 No. 107.1 Building Automation Recognized Component, ITE, E137632 UL 60950 E137632 Instrumentation - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition CUL/CSA-C22.2 No. 234-M90 Recognized Component, Haz. Loc., E234790 UL 60950 E137632 Features - ISA 12.12.01, CSA C22.2 No. 213 CUL/CSA-C22.2 No. 234-M90 Ultra slim 15W footprint - Class I, Division 2, Groups A, B, C, D No tools required for mounting - IEC/EN60950-1, 2nd Edition Adjustable output TM RoHS Compliant PowerBoost industrial overload design Overvoltage, short circuit protection Related Products Continuous short circuit protection SDN Series Low output noise SCP Series Screw terminal connections Selection Table Catalog Number DC Output Voltage Output Current Ripple / Noise Size (H x W x D) - in. (mm) 5 - 6 V 5 A SDP 5-5-100T 10 - 12 V 3 - 2.5 A SDP 2-12-100T 2.95 in x 1.77 in x 3.58 in (75.0 mm x 45.0 mm x 91.0 mm) 12 - 15 V 4.2 - 3.4 A SDP 3-15-100T 48 - 56 V 1 A SDP 1-48-100T 2.95 in x 0.9 in x 3.8 in 0.6 A <50 mVpp SDP 06-24-100T (75.0 mm x 22.8 mm x 96.7 mm) 1.3 A SDP 1-24-100T 2.95 in x 1.77 in x 3.58 in (75.0 mm x 45.0 mm x 91.0 mm) 24-28 Vdc 2.1 A SDP 2-24-100T 3.8 A SDP 4-24-100LT 2.95 in x 2.85 in x 3.8 in (75.0 mm x 72.5 mm x 96.7 mm) 4.2 A SDP 4-24-100RT * * NEC Class 1 Contact Technical Services at (800) 377-4384 with any questions. 134 Visit our website at www.solahd.com. Power Supplies 3 SDP Series Specifications (24 V models) Catalog Number Description SDP 06-24-100T SDP 1-24-100T SDP 2-24-100T SDP 4-24-100LT SDP 4-24-100RT Input 1 85-264 Vac, 90-375 Vdc 85-132 / 176-264 Vac, 210-375 Vdc Input Voltage 47-63 Hz Input Frequency 0.4 A / 0.25 A 0.7 A / 0.4 A 1.1 A / 0.7 A 1.8 A / 1.0 A 2.2 A / 1.2 A Input Current Not required. Unit provides internal fuse (T3A, not accessible) External Fusing > 25 ms Hold-Up Time > 80% typ. > 83% typ. > 86% typ. > 88% typ. Efficiency < 3.75 W typ. < 6.1 W typ. < 8.1 W typ. < 12 W typ. Losses Output 24 V (22.5 - 28.5 Vdc Adj.) 24 V (24 - 25.7 Vdc Adj.) 24 V (22.5 - 28.5 Vdc Adj.) Output Voltage Voltage Regulation Static 0.5% V , dynamic + 2% V overall out out 2 < 50 mVpp Ripple/Noise > 26 Vdc, but < 27.2 > 30 Vdc, but < 33 Vdc, > 30 Vdc, but < 33 Vdc, auto recovery Overvoltage Protection (OVP) Vdc, auto recovery auto recovery Output Noise Radiated EMI values below EN61000-6-2 Suppression Rated Continuous 0.63 A 24 Vdc / 1.3 A 24 Vdc / 2.1 A 24 Vdc / 4.2 A 24.5 Vdc / 3.8 A 24.5 Vdc 0.54 A 28 Vdc 1.1 A 28 Vdc 1.8 A 28 Vdc 3.6 A 28 Vdc Loading Continuous operation at overload/short-circuit: up to 1.5 x Nominal Current Continuous Overload Behavior Unit is continuously protected against short-circuit, overload and open-circuit. Protection 35 V Power Back Immunity Installation Green LED on, when V OK. Status Indicators out Molded plastic housing using UL 94 approved flameproof material rating 94V-2. Case & Mounting Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Dimensions 2.95 x 0.90 x 3.80 2.95 x 1.77 x 3.58 2.95 x 2.85 x 3.80 H x W x D - inches (mm) (75.0 x 22.8 x 96.7) (75.0 x 45.0 x 91.0) (75.0 x 72.5 x 96.7) Weight - lbs (kg) 0.4 lbs (.18 kg) 0.5 lbs (.23 kg) 0.7 lbs (.32 kg) Standard: Vertical Optional: Horizontal or on top (Contact Technical Services). Mounting Orientation Ventilation/Cooling Normal convection, no fan required Above/below: 25 mm recommended. Free space for cooling Connection 2 Input: screw terminals, connector size range: 20-12AWG (1.5 - 6 mm ) for solid or stranded conductors. Connector size range General Electromagnetic EN61000-6-3 (Includes EN61000-6-4) Class B (EN 55022) incl. Annex A Emissions (EMC) Electromagnetic EN61000-6-2 (Includes EN61000-6-1) (EN55024) Criterion A: no derogation of performance Immunity (EMI) Storage: -25C to +85C Operation: -10 to +60C full power with linear derating to half power from 60C to 70C. Temperature (Convection cooling, no forced air required). > 500,000 hours according to Telcordia/Bellcore Document SR-332, Issue 1 MTBF Up to 90% RH, noncondensing IEC 68-2-2, 68-2-3 Humidity SELV (acc. EN60950) Safe Low Voltage IP20 (IEC529), Protection Class 1 (IEC536) Protection Class/Voltage 3 year limited warranty Warranty Notes: 1. Not UL listed for DC input. 2. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. Contact Technical Services at (800) 377-4384 with any questions. 135 Visit our website at www.solahd.com.