Power Supplies Silver Line Series Single & Multi-Output Linears The SolaHD Silver Line Series follows the industry accepted footprint for open frame, linear power supplies. Standard screw terminal connections and optional covers are offered for safety considerations. Applications Industrial Control Circuits and Components Instrumentation E137632 Drives Specifications CNC Machinery Parameter Condition Limit Equipment for food industry Input Microprocessor Circuits 100/120/220/230/240 Input Voltage Vac Selectable Analog Circuits 47-63 Hz Input Frequency Noise sensitive Circuitry and Sensors Output for 10% change 0.05% Line Regulation Features for 50% change 0.05% Load Regulation 3.0 mV maximum Easy-to-install screw terminal connections Ripple Peak-to-Peak Cover options DC Output 5% Minimum Adjustment Range Industry standard footprint All 5-Volt outputs include Universal input and approvals (115/230 Vac) build-in OVP as standard Overvoltage (setting is 6.2 V 0.4 V) Low noise, extremely quiet DC output. For noise Protection OVP is optionally sensitive or analog circuitry. available on other types Transient Fast transient response. Ideal for test applications. at 50% Load Changes 50 msec. Response Time Built-in OVP on 5 V models and optional on Automatic current Overload 12, 15 and 24 V models limit foldback Protection Available to compensate Automatic resetting overload protection for output voltage drop 0.5 Vdc Remote Sensing Short circuit protected on selected models. General Two year limited warranty Operating Derate to 40% at +70C 0 to +50 C Temperature Range Certifications and Compliances Storage -25 C to +85 C Temperature Range Recognized Component, ITE UL 60950 E137632 Temperature - UL 60950-1/CSA C22.2 N0. 60950-1 CUL/CSA-C22.2 0.01% 0 C No. 234-M90 Coefficient (Typical) After warm-up .5% Stability For most system Linear power supplies applications they will have inherently low EMI/RFI meet requirements of conducted and radiate FCC Class B and VDE noise levels 0871 for Class B Derate power by an additional 15% Cover Option Forced air. 20 CFM required for full rating Cooling Derate 30% without cooling Specifications are typical. Load Regulation on outputs without Remote Sense, .1% typical. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 174 February 2021Power Supplies SL Series Selection Table Dimensions - inches (mm) Catalog Number Output 1 Output 2 Output 3 Case 2 5 V 3 A * A SLS-05-030-1T 2 B1 SLS-05-060-1T 5 V 6 A * 2 C SLS-05-090-1T 5 V 9 A * 2 I2 SLS-05-120-1T 5 V 12 A * 2 12 V 1.7 A or 1 A SLS-12-017T 15 V 1.5 A 2 12 V 3.4 A B1 SLS-12-034T 2 SLS-12-051T 12 V 5.1 A C 2 12 V 6.8 A I2 SLS-12-068T 2 SLS-15-045T 15 V 4.5 A C 2 15 V 6 A I2 SLS-15-060T SLS-24-012T 24 V 1.2 A v A 2 24 V 2.4 A B2 SLS-24-024T Case A 2 24 V 3.6 A C SLS-24-036T 2 24 V 4.8 A I2 SLS-24-048T 2 24 V 7.2 A K SLS-24-072T 2 24 V 12.0 A L SLS-24-120T 12 V 1 A or -12 V 1 A or 1 H1 SLD-12-1010-12T 15 V .8 A -15 V .8 12 V 1.8 A or -12 V 1.8 A or 1 D SLD-12-1818-12T 15 V 1.5 A -15 V 1.5 A 2 2 12 V 3.4 A -12 V 3.4 A I3 SLD-12-3434-12T 2 2 15 V 3 A -15 V 3 A I3 SLD-15-3030-15T 2 2 12 V 3.4 A I1 SLD-12-6034-05T 5 V 6 A * 2 12 V 1.5 A C1 SLD-12-3015-05T 5 V 3 A * 12 V .4 A or -12 V .4 A or 1 2 H2 SLT 12-20404-12T 5 V 2 A * 15 V .4 A -15 V .4 A 2 2 12 V 1 A or -12 V 1 A 1 2 F SLT 12-31010-12T 5 V 3 A * 15 V .8 A or -15 V .8 A -12 V 1.8 12 V 1.8 A or 1 2 SLT 12-61818-12T 5 V 6A * A or -15 V G2 15 V 1.5 A 1.5 A Over Voltage Protector (OVP) Case B 6.2 V to 34 V For Cases B through K J1 SLO-12-000-1 Adjustable 8 A 6.2 V to 34 V For Case A or Cases B through K Cover Options SLO-12-000-TB J2 Adjustable 8 A (when used with a cover) Catalog Catalog Notes: Description Description Number Number * With Built-In OVP Cover for Cases Cover for Case A SLCASA-CVR SLCASI-CVR 1. 12/15 Volt models are factory set for 12 Volt operation. 15 Volt operation I1, I2, & I3 is field adjustable. Cover for Case B Cover for Case K SLCASB-CVR SLCASK-CVR 2. With Remote Sense (R.S.) Cover for Case C Cover for Case L SLCASC-CVR SLCASL-CVR Note: Covers are sold separately. When used, derate the power supply by 15% of its rated value. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 175 February 2021