Power Protection and Conditioning STFE Elite Series - SolaHD Tracking Filters with Surge Protection The STF Elite DIN Rail Mount Series combines SolaHD Tracking technology with UL Listed surge protection to protect against the full spectrum of voltage transients and surges. It continuously tracks the input AC power line responding instantly into action upon detecting extraneous high-frequency noise and high-voltage transients caused by everyday events such as turning on machinery, motors or equipment. The STFE Series attenuates or reduces the amplitude of normal mode noise to a minimum of -90 dB that occurs in a frequency range of 100 kHz to 50 MHz, and common mode noise to a minimum of 60 dB that occurs in a frequency E324279 range of 5 MHz to 50 MHz. STFE provides the industrys best IEEE C62.41 Category A and B Ringwave protection. The STFE Series is built to meet your unique requirements, Certifications and Compliances and are available in hardwired DIN Rail mount, single phase configuration. They are designed for years of trouble free UL Recognized Component operation and require little or no operator intervention after - UL 1449, Type 4 locations installation. - UL 1283 - CSA C22.2 No. 8 Applications ABS Type Approval (Pending) Control Panels CE Compliance (Pending) Factory Automation Installations RoHS Compliant Point of Use Industrial Equipment Programmable Logic Controllers Related Products Dedicated Industrial and Machine Tools Equipment Power Conditioners Uninterruptible Power System Features Power Supplies Series connected DIN Rail mounted filter Durable metal mount clip Selection Table Transient protection in all modes (L-N, L-G, and N-G) Single phase applications up to 20 Amps Catalog Number Input Voltage Operating temperature from -40 C to +50 C 120 V Single Phase, 2 Wire + Ground STFE03010N (-40 F to +122 F) 120 V Single Phase, 2 Wire + Ground STFE05010N Screw terminal connections - Reliable and convenient screw clamp connections 120 V Single Phase, 2 Wire + Ground STFE10010N - Accept 10-16 AWG wire 120 V Single Phase, 2 Wire + Ground STFE20010N - Meet IP20 specifications for ingress protection 240 V Single Phase, 2 Wire + Ground STFE03024L LED status indication Form C contact for remote monitoring 240 V Single Phase, 2 Wire + Ground STFE05024L Five year limited warranty 240 V Single Phase, 2 Wire + Ground STFE10024L 240 V Single Phase, 2 Wire + Ground STFE20024L Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 33 January 2021Power Protection and Conditioning STFE Elite Series - SolaHD Tracking Filters with Surge Protection Specifications Description STFEXXX10N STFEXXX24L 120 V (0-150 Vrms) 240 V (0-275 Vrms) Input Voltage 47 - 63 Hz Line Frequency < .5 nanoseconds normal mode, <5 nanoseconds common mode Response Time Fully Enclosed Metal Housing Enclosure Reference Fuse/Circuit Breaker Chart Fusing Green LED OK/form C Contact/10 Amps 250 Vac or 5 Amps 100 Vdc Status Indication DIN Rail Mount Connection/Mounting Type -40 C to +50 C (-40 F to +122 F) at full load Derate Linearly to 60% at +70 C (+158 F) Operating Temperature 1.7 (0.70) Weight - lbs (kg) 4.88 x 2.56 x 4.56 Dimensions - in (mm) (124.0 x 65.0 x 116.0) (H x W x D) 0% to 95% Non-condensing Operating Humidity Per Phase 19,500 Amps Line to Neutral 13,000 Amps Peak Surge Current Capability Line to Ground 6,500 Amps Neutral to Ground 6,500 Amps 10 milliseconds 5 x Nominal Load Surge Current Rating 1 second 3 x Nominal 10 seconds 2 x Nominal Frequency Response 100 kHz to 50 MHz -90 dB Max Normal Mode (Forward-Reverse) 5 MHz to 50 MHz -60 dB Max Common Mode (Forward-Reverse) Typical Category A Ringwave < 60 V Peak (6 kV, 200 A, 100 kHz) Transient Reduction (IEEE C62.41) Typical Category B Ringwave <100 V Peak UL 1449 (6 kV, 500 A, 100 kHz) 5 year limited warranty Warranty Connection Diagram LINE INPUT FROM SOURCE LINE LOAD L/L1 L/L1 L/L1 L/L1 TO LOAD OR EQUIPMENT N/L2 N/L2 N/L2 N/L2 PROTECT RELAY CONTACTS GND GND GND GND NO COM NC TO REMOTE INDICATION IF NEEDED Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 34 January 2021