Uninterruptible Power Supplies SDU AC -A Series, DIN Rail UPS The SDU AC - A Series DIN Rail UPS combines an industry leading compact design with a wide operation temperature range, enhanced communication and unique installation options. The SDU series provides economical protection from damaging impulses and power interruptions. These units include easy to wire screw terminations for critical devices needing battery back up such as computer based control systems. Applications Programmable Logic Controllers Factory Automation E179213 Robotics Conveying Equipment Certifications and Compliances Computer-based Control Systems - Low Voltage Directive: EN62040-1 Features - EMC Directive: EN62040-2 Lightweight, compact industrial design Class 1 Division 2 - ANSI ISA 12.12.01/CSA 213 Communications port for optional Industrial Ether net Pending protocols or discrete communication card RoHS Compliant W ide operation temperature range (0 C to 50 C) UL Recognized Component, UPS Equipment Cold start capability UL 60950 E137632 - UL 1778 5th Ed., CSA C22.2 No. 107.3 CUL/CSA-C22.2 Software and cable included for easy installation No. 234-M90 - Suitable for UL 508 at full load output (no derating) and Simulated sinewave output Ind. Control Equipment Applications USB communication port - CSA C22.2 No. 107.1 Remote tur n-on and shutdown capabilities - Overvoltage Cat III, Pollution Degree III Two year limited warranty - ODVA Compliant Panel/wall mounting brackets (optional) EtherNet/IP SDUENETIPCARD has been tested and approved for conformance by the ODVA. More information about EtherNet/IP and the ODVA can be obtained from the following website: www.odva.org. Related Products Portable MCR Power Conditioners STV Surge Protective Devices SDN DIN Rail Power Supplies STFV Plus Active Tracking Filters Selection Table Typical Back-Up Time Catalog Capacity Input/Output Approx. Ship Volts, Frequency In/Out (minutes) Number (VA/W) Connections Weight - lbs (kg) At full load/half load. 500/300 4/18 10.6 (4.8) SDU 500A 120 Vac, 50/60 Hz 850/510 2/10 11.5 (5.2) SDU 850A IP20 touch proof, screw terminals. W ire range: 10 ~ 18 AWG. 500/300 4/18 10.6 (4.8) SDU 500A-5 230 Vac, 50/60 Hz 850/510 2/10 11.5 (5.2) SDU 850A-5 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 67 January 2017Uninterruptible Power Supplies Specifications Catalog Number SDU 500A SDU 850A SDU 500A-5 SDU 850A-5 500/300 850/510 500/300 850/510 Capacity (VA/Watts) 0.6 Load Power Factor Dimensions - inches (mm) 4.87 x 11.1 x 4.81 (123.7 x 281.9 x 122.3) Unit (H x W x D) - in. (mm) 10.6 (4.8) 11.5 (5.2) 10.6 (4.8) 11.5 (5.2) Weight - lbs (kg) Input Parameters 120 V (+10%, -20%) 230 V (+/- 15%) Voltage 50 +/- 5 Hz or 60 Hz +/- 6 Hz (auto sensing) Frequency Output AC Parameters Simulated sinewave Voltage (Battery Mode) +/- 5% 50 or 60 Hz +/- 0.3 Hz Frequency (On Battery) UPS automatic shutdown if overload exceeds: 105% of nominal at 20 seconds, Overload Protection 120% of nominal at 10 seconds, 130% of nominal at 3 seconds UPS shutdown, auto-recovery Short Circuit Battery Parameters Sealed, non-spillable, maintenance-free lead acid batteries Battery Type 4 - 6 ms typical Transfer Time Back-Up Time (minutes) 4/18 2/10 4/18 2/10 Full Load/Half Load 8 hours to 90% capacity of full discharge Recharge Time Environmental 0 C to 50 C Operating Temperature -15 C to 60 C Storage Temperature 0 to 95%, non-condensing Relative Humidity 0-95% humidity non-condensing, 0-50 C up to 5,000 ft. (1500m) Ambient Operation < 40dBA (1 meter from surface) Audible Noise Standards FCC Part 15, Subpart B, Class A Level 4 EMC: EN62040-2 EN55032 CISPR22 EMC EN61000-3-2 IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -2-2 5000 ft. without derating Elevation Meets IEEE C62.41, Category A Surge Protection Operating - IEC60068-2-27, Half Sine Wave: 10G for a duration of 11ms, shock for 1 direction (X axis) Shock Non-operating - IEC60068-2-27, Half Sine Wave : 30G for duration of 11ms, 3 shocks for all 3 axes Operating - IEC60068-2-6, Sine Wave: 10Hz to 500Hz 19.6m/S, displacement of 0.35mm, 60 min per axis for all X, Y, Z direction. Vibration Non-operating - IEC60068-2-6, Random : 5hz to 500Hz (2.09Grms) 20 min per axis for all X,Y,Z To be mounted on DIN TS35/7.5 or TS35/15 rail system. Chassis mounting permissible via optional brackets (SDU-PMBRK). Mounting Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 68 January 2017