Power Supplies 3 SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications. Power factor correction to meet European directives, hazardous location approvals and optional redundant accessories allow the SDN series to be used in a wide variety of applications. Wide operation temperature range, high tolerance to shock and vibration and reliable design make the SDN series the preferred choice of users. UL 60950 E137632 EMC and E61379 UL 508 Listed E137632 Low Volt. E234790 IND. CONT. EQ. CUL/CSA-C22.2 Directive Applications E61379 No. 234-M90 Industrial/Machine Control Certifications and Compliances * Process Control All Models Conveying Equipment Listed, Ind. Control Equipment, E61379 Material Handling UL 508 Listed - UL 508, CSA C22.2 No. 107.1 IND. CONT. EQ. Vending Machines E61379 UL Recognized Component, ITE, E137632 UL 60950 Packaging Equipment E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition CUL/CSA-C22.2 No. 234-M90 TM DeviceNet UL Recognized Component, Haz. Loc., UL 60950 E137632 E234790 Amusement Park Equipment CUL/CSA-C22.2 No. 234-M90 - ISA 12.12.01, CSA C22.2 No. 213 Semiconductor Fabrication Equipment - Class I, Division 2, Groups A, B, C, D - Low Voltage Directive Features - IEC/EN60950-1, 2nd Edition Power Factor Correction (per EN61000-3-2) Sag Immunity: SEMI F47 Auto Select 115/230 Vac, 50/60 Hz Input RoHS Compliant Improved metal mounting clip DC OK Signal Models SDN 2.5-24-100P, SDN 4-24-100LP Adjustable Voltage Class 2 per UL 1310, CSA C22.2 No. 223 Parallel Capability standard on all units Related Products Industrial grade design SDP Series - -10C to 60C operation without derating. Indefinite short circuit, overvoltage and overtemperature protection. SCP Series - Powers high inrush loads without shutdown or foldback SCL Series - Rugged metal case and DIN connector SDU UPS Narrow width on rail for space critical applications User-friendly front panel - Large, rugged, accessible, multiple connection screw terminations - Easy installation 12 Vdc and 48 Vdc single phase models available Highly efficient >90% switching technology High MTBF and reliability Accessories Chassis Mount Bracket (SDN-PMBRK2) * Refer to user manual for installation requirements when used in hazardous locations. Contact Technical Services at (800) 377-4384 with any questions. 123 Visit our website at www.solahd.com. Power Supplies 3 SDN-P Specifications (Single Phase), 24 Vdc Output Catalog Number Description SDN 2.5-24-100P SDN 4-24-100LP SDN 5-24-100P SDN 10-24-100P Input Nominal Voltage 115/230 Vac, Auto select 85-264 Vac 85-132/176-264 Vac -AC Range 1 90 - 375 Vdc 210 - 375 Vdc -DC Range 47 - 63 Hz -Frequency 2 1.3 / 0.7 A 2.1 / 1.0 A 2.2 / 1.0 A 5 / 2 A typ. Nominal Current typ. < 25 A typ. < 20 A typ. < 40 A -Inrush current max. 3 > 87.5% typ. (8.6 W) > 88% typ. (13.1 W) > 88% typ. (16.4 W) > 88% typ. (32.7 W) Efficiency (Losses ) Units Fulfill EN61000-3-2 Power Factor Correction Output 24 Vdc 24 Vdc 24 Vdc Nominal Voltage (22.5 - 28.5 Vdc adj.) (22.5 - 28.5 Vdc adj.) (22.5 - 28.5 Vdc adj.) < 2% overall (combination Line, load, time and temperature related changes) -Tolerance 4 < 50 mVpp -Ripple < 33 Vdc < 27 Vdc < 33 Vdc Overvoltage Protection 2.5 A (60 W) 3.8 A (92 W) 5 A (120 W) 10 A (240 W) Nominal Current Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) -Current Limit 5 > 20 ms full load Holdup Time Single or Parallel use is selectable via Front Panel Switch Parallel Operation (SDN 2.5, 4 should not be used in parallel as Class 2 rating would be violated.) General EMC: EN61000-6-3, -4 Class B EN55011, EN55022 Radiated and Conducted including Annex A. EN61000-3-2 -Emissions EN61000-6-1, -2 EN61000-4-2 Level 4, EN61000-4-3 Level 3 EN61000-4-6 Level 3 EN61000-4-4 Level 4 input and Level 3 output -Immunity EN61000-4-5 Isolation Class 4, EN61000-4-11 o o o o o Storage: -25 C...+85 C Operation. -10-60 C full power with operation to 70C possible with a linear derating to half power from 60 C to 70 C (Convection cooling, no forced air required). Temperature Operation up to 50% load permissible with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing IEC 68-2-2, 68-2-3. Humidity > 820,000 hours > 640,000 hours > 600,000 hours MTBF: o Bellcore Issue 6 Method 1 Case 3 40 C - Standard 5 year limited warranty Warranty Protected against continuous short-circuit, overload, open-circuit. Protection Class 1 (IEC536), General Protection/Safety degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc. EN60950) Green LED and DC OK signal (N.O. Solid State Contact rated 200 mA / 60 Vdc) Status Indicators Installation Fusing Inter nally fused. Exter nal 10 A slow acting fusing for the input is recommended to protect input wiring. -Input Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/ -Output loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required). Mounting 2 2 Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm ) for solid conductors. 16-12 AWG (0.5-4 mm ) for Connections 2 flexible conductors. Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm ) for solid conductors. Fully enclosed metal housing with fine ventilation grid to keep out small parts. Case 25 mm above and below, 25 mm 70 mm above and below, 25 mm 25 mm above and below, left and right, left and right, -Free Space 25 mm left and right, 10 mm in front 15 mm in front 15 mm in front 4.88. x 1.97 x 4.55 4.88 x 2.56 x 4.55 4.88 x 3.26 x 4.55 H x W x D inches (mm) (124.0 x 50.0 x 116.0) (124.0 x 65.0 x 116.0) (124.0 x 83.0 x 116.0) 1.6 (.73) 2.4 (1.10) 3.3 (1.50) Weight lbs (kg) 4. Ripple/noise is stated as typical values when measured with a 20 MHz, 1. Not UL listed for DC input. 2. Input current ratings are conservatively specified with low input, worst case bandwidth scope and 50 Ohm resistor. 5. Full load, 100 Vac Input T = +25C efficiency and power factor. amb 3. Losses are heat dissipation in watts at full load, nominal input line. Contact Technical Services at (800) 377-4384 with any questions. 124 Visit our website at www.solahd.com.