Revised : 2015-01-24 TYPE MV002 Series Relay TYPE MV002 Series Relay Issued : 2012-08-22 Type List Designation (provided with) Terminal Contact Flanged cover style form Dust cover Flux tight (Dust cover) MV002-1AH-F-D MV002-1AH-F-D1 Plug-in terminal ------ MV002H-1AH-F-D MV002H-1AH-F-D1 1A (SPDM) MV002P-1AH-F-C PCB terminal ------ ------ MV002HP-1AH-F-C Ordering Information MV002 H P - 1A H - F - C - R1 XXX 1 2 3 4 5 6 7 8 9 1. MV002 -- Basic series designation S -- Sealed type washable D1 -- Flanged cover (Dust cover) 2. Blank -- Standard C1 -- Flanged cover (Flux tight) H -- High power type S1 -- Flanged cover (Sealed type washable) D1SW -- Steel bracket (dust cover with weather 3. Blank -- Socket terminal proof) P -- PCB terminal D1SF -- Steel bracket (dust cover with shroud) D1S -- Steel bracket (dust cover) 4. 1A -- Single-pole, double-make (SPDM) C1S -- Steel bracket (flux tight) S1S -- Steel bracket (sealed type washable) 5. H -- Contact material Ag alloy 8. Blank -- Standard type 6. Blank -- Standard type R1 -- Coil parallel with resistor 1/2W for F -- Class F 12V 680 7. D -- Dust cover 9. XXX -- Special feature code C -- Flux tight Contact Rating Type Standard High power type 30A 60VDC 40A 60VDC Rated load (Resistive) 20A 72VDC Max. Switching Capacity 1800W 2400W P. 1 / 3 ENMV00201 Revised : 2015-01-24 TYPE MV002 Series Relay TYPE MV002 Series Relay Issued : 2012-08-22 Coil Rating (DC) Pick up Drop out Max. Power Rated Rated current Coil resistance Voltage Voltage continuous consumption voltage 10 % at 23C 10 % at 23C (Max) (Min) voltage at rated (V) (mA) () (1) at 23C at 23C at 23C voltage 12 133.3 90 75% of 5% of 130% of 24 66.7 360 rated rated rated approx. 1.6W voltage voltage voltage 48 33.3 1440 Notes (1) Without contact load. Specification Contact material Ag alloy (1) Voltage drop Typ.50 mV at 10A (1) Operate time 20ms Max. (1) Release time 20ms Max. (1) Insulation resistance 20M Min. (DC 500V) Between open contact : AC 750V, 50/60Hz 1 min. (1) Dielectric strength Between contact and coil : AC 750V, 50/60Hz 1 min. Operating extremes 10~500Hz, 5.0G Vibration resistance Damage limits 10~500Hz, 5.0G Operating extremes 10G Shock resistance Damage limits 100G 1000,000 operations Mechanical (frequency 9,000 operations/hr) Life expectancy 10,000 operations Electrical (frequency 600 operations/hr) Operating ambient temperature -40+85C (no freezing) Weight Approx. 40 g Note(1) Initial value. Operate and release time excluding contact bounce. (2) All tests are conducted under room temperature and room humidity. (3) Consider the heat of PCB is necessary, please check the actual condition of PCB. (4) If it includes ripple, the ripple factor should be less than 5%. And do not have a parallel connection with diode for the purpose of coil surge instead of diode, a varistor (ZNR) is recommend for the absorber. (5) Do not use the relay exceeding the coil rating, contact rating and life expectancy, or this may cause the risk of overheating. (6) To assure optimum performance, avoid the relay from dropping, hitting, or other unnecessary shocks. (7) Do not switch the contacts without any load as the contact resistance may become increased rapidly. P. 2 / 3 ENMV00201