ColdMark Data Sheet Specifications Indication Type Visual, irreversible clear to violet color change Activation Temperature Levels Sensitivities available between -3C and 10C. See Product Selection table for details. Temperature Accuracy +1C / +2F Activaoti n Temperature Exposure Time Period 30 minutes or less Product Life 2 years Mounting Method Pressure-sensitive adhesive Storage Conditions Unused product must be stored above activation temperature and below 43C / 110F Dimensions 3.3 x 0.8 x 0.4in / 83.82 x 20.32 x 10.16mm Weight (varies by sensitivity) 3.06g Product Selection Part Number Activation Temp CM -3/-26 -3C/26F ColdMark should be used when monitoring products that must be maintained at temperatures above a specified temperature CM 0/32 0C/32F CM 2/36 2C/36F CM 5/41 5C/41F CM 10/50 10C/50F Pressure-Sensitive Adhesive Data Product Descripoti n High performance, acrylic pressure-sensitive adhesive (2 mil thick film) that provides excellent adhesion to most smooth surfaces Provides aggressive tack and high shear strength Excellent UV light stability and elevated temperature resistance Temperature Range Guidelines Physical Properties Typical Values* Application: Above 10C/50F for best performance Quick Tack End Use: -40C to 121C/-40F to 250F 4.0 lbs./sq.in. Stainless Steel Peel Adhesion Chemical Resistance 4.1 lbs./in. Stainless Steel - 30 minute residence Resistant to water, detergent, alcohol, aliphatic and some aromatic Shear hydrocarbons. Not recommended for use in contact with active solvents 300+ hours to fail Stainless Steel - 1000 g/sq. in. 72F such as ketones, esters, and some chlorinated hydrocarbons. Thickness *Values given are typical and are not necessarily for use in specifications. Product reinforced .002 inches Adhesive only with 2 mil PET during adhesion tests. www.spotsee.io 1Drawings How to Mount Temperature indicators are best suited for monitoring product or the controlled environment of the product. ColdMark descending temperature indicators are best used when mounted directly to the product being monitored or when placed inside the product shipper. Indicators should not be placed directly on gel packs, phase change materials, etc. In rare cases, temperature indicators are mounted on external packaging to monitor ambient temperature conditions. This product contains Ethylene Glycol a chemical known to the state of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov/product. Rev:08/2019