ShockLog Cellular Data Sheet The ShockLog Cellular Impact Recording and Tracking System combines advanced tri-axial piezoelectric accelerometer technology with sophisticated electronics and software to oeff r an advanced shock and vibration data logger with real-mti e tracking. When a programmed impact level is exceeded, a detailed event curve will be recorded, and the ShockLog Cellular module will send a real-mti e alert leng ytti ou know when and where a potenati lly damaging impact has occurred. Benet ffi rom knowing where your asset is with location messages sent on a user programmable interval (1 hour to 24 hours). ShockLog Cellular System Specifications ShockLog Impact Recording Device System Specification Operating Temperature Range -40C to 85C / -40F to 185F 4.8 in x 3.1 in x 2.2 in Dimensions 123 mm x 78 mm x 55 mm Weight 1.1 lbs / 515 g without batteries Batteries 3.6V lithium or 1.5V alkaline AA Battery Life* Up to 18 months Case Material Aluminum Case Rating IP67 Web Hosted Application Supported on Chrome, IE & Firefox ShockLog Desktop Software Functions on Windows XP, Vista, 7, 8, 10 Cellular Communications / Interfaces USB 2 iBuott n A-D Converter Resolution 12 bits Flash Memory for Data 4096 kbytes Data Collection Event Processor Wake-up Delay 0.25 ms Timeslot Interval 600 to 3600 seconds Samples per Channel per Event 512 to 4096 (user defined) Maximum Number of Events (detailed) 108 to 870 (user defined) Event Duration 1 to 128 seconds (user defined) *Battery Tips Always use lithium batteries for journeys where the temperature may be outside the -5C to +50C range. The capacity of alkaline batteries drops dramatically when exposed to temperatures below 10C. If using a lithium battery and the ShockLog will be traveling by air, make sure the battery is approved for air cargo. If the batteries are accidentally installed with the wrong polarity, the ShockLog will not be damaged however, the life of the battery may be severely affected. www.spotsee.io 1 ShockLog Cellular Data Sheet Accelerometers Low Frequency Cutoff (-3dB 10g 100g) 0.1 - 0.5 Hz High Frequency Cutoff (-3dB) 250 300 Hz Hardware Filters (Programmable) 10 Hz, 40 Hz, 50 Hz, 90 Hz, 120 Hz and 250 Hz Resolution (% of full scale) 1% for Peaks 0.1% Scale Factor Accuracy at 5G (event record) 2% Additional Error Other Ranges 2% Additional Error Peak Capture 5% Change of Scale Factor over Temperature 4% Acceleration Ranges 1% to 200 G Wake-up Threshold (% of range)** 5 to 95% Warning and Alarm Thresholds (% of range)** 7 to 95% Humidity/Temperature Specifications* Temperature Measuring Range -40 to 85 C / -40 to 185 F Temperature Accuracy 2 C / 4 F Temperature Resolution 0.1 C Humidity Measuring Range 0 - 100% RH Humidity Accuracy 3% RH Humidity Resolution 0.1% RH -40C to 85 C / -40 F to 185 F Dew Point Measuring Range 0 - 100% RH Dew Point Relative Accuracy 2 C / 4 F (-20 to 70C, 25 to 75% RH) Dew Point Resolution 0.1 C Tilt & Roll Specifications Tilt Range Monitored 180 Resolution 0.1 Transverse Sensitivity 5% **Recommend 2% minimum difference between wake up and warning and between warning and alarm www.spotsee.io 2