DATA SHEET Liquid Level Switches Honeywell LLE Standard Temp Series Alternatives For part numbers LLE101000, LLE102000, LLE103000 and LLE105000 FEATURES Liquid level switches that can detect almost any liquid type oil or water based Choice of mounting internal or external Choice of threads Housing/ Output Supply Output Temp Mounting Type/Logic Voltage Current BENEFITS OUTPUT VALUES b Output Voltage (Vout): lout = 100mA Low power Output High Vout = Vs - 1.5V max Low cost Output Low Vout = 0V + 0.5V max Compact design TECHNICAL SPECIFICATIONS Supply voltage (Vs) 4.5V to 15.4V DC DC Supply current (ls) 2.5mA max. (Vs = 15.4V ) DC Output sink and source Other sensor options available on request, email: current (lout) 100mA technical sstsensing.com Operating temperatures -25C to +80C Storage temperatures -30C to +85C Need help Ask the expert a Housing material Polysulfone Tel: + 44 (0)1236 459 020 and ask for Technical Sensor termination 24AWG, 250mm PTFE wires, 8mm tinned a) Before use check that the fluid in which you wish to use these devices is compatible with Polysulfone. b) Voltages applicable to output value stated. NOTES OUTLINE DRAWING HOUSING SPECIFICATIONS All dimensions shown in mm. Tolerances = 1mm. Housing Series - External Mounting Type 1 Type 2 Type 1 M12x1x8g Thread M12x1x8g with c hex nut d Pressure 7 bar / 101 psi maximum Tightening 1.5 Nm / 13.26 in-lbs maximum Torque Type 2 Housing Series - Internal Mounting Type 3 Type 5 M12x1x8g Thread with M10x1 c hex nut d Pressure 7 bar / 101 psi maximum Tightening 1.5 Nm / Not Applicable Torque 13.26 in-lbs maximum Type 3 NOTE: In the cases of Type 1 and Type 3 sensors, the rear of the SST sensors are slightly longer than the Honeywell sensors. NOTE: The dimensions of the Type 5 part make it a push in part the same as LLE105000. Note that the sensor can also be secured using an M10 nut. ELECTRICAL INTERFACE Type 5 Wire Designation Red Vs Green Output Blue 0V c) Hex nut and washer supplied with Type 1, Type 2 and Type 3. NOTES d) When correctly sealed.