A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components Series Datasheet HE Reed Relays www.standexmeder.com HE Series Reed Relays Features: High Voltage Relay, Through-Hole / Axial Wire Option, Compact Design, Special Pin-Outs Applications: High Voltage Test Sets, Cable Testers, Medical Equipment & Others Markets: Medical, Test and Measurement & Others Part Description: HE 00 - 0 X -00 -00 Nominal Voltage Contact QTY Contact Form Switch Model Pin Out 05, 06, 12, 24, 48 1, 2 A, B 69, 83 02, 03, 150, 300 Customer Options Switch Model Unit Contact Data 69 83 Rated Power (max.) 50 50 W Any DC combination of V&A not to exceed their individual max.s Switching Voltage (max.) 10,000 7,500 V DC or peak AC Switching Current (max.) 3.0 3.0 A DC or peak AC Carry Current (max.) 5.0 5.0 A DC or peak AC Contact Resistance (max.) 150 150 mOhm 0.5V & 50mA Breakdown Voltage (min.) 15 10 kVDC According to EN60255-5 Operating Time (max.) 3.0 3.0 ms Incl. Bounce Measured with w/ Nominal Voltage Release Time (max.) 1.5 1.5 ms Measured with no Coil Excitation Insulation Resistance (typ.) 12 12 10 10 Ohm Rh<45%, 100V Test Voltage Capacitance (typ.) 0.2 0.2 pF 10kHz across open Switch USA: +1.866.782.6339 salesusa standexmeder.com Version 01 Europe: +49.7731.8399.0 info standexmeder.com 27.01.2015 Asia: +86.21.37820625 salesasia standexmeder.com Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components Series Datasheet HE Reed Relays www.standexmeder.com Coil Data Coil Voltage Coil Resistance Pull-In Voltage Drop-Out Voltage Nominal Coil Power Contact Switch (nom.) (typ.) (max.) (min.) (typ.) Form Model Unit VDC Ohm VDC VDC mW 12 110 9 1 1,310 69 24 465 18 2 1,240 1A 12 260 9 1 554 83 24 1050 18 2 554 12 260 9 1 554 69 24 1,050 18 2 548 1B* 12 410 9 1 351 83 24 1,520 18 2 378 2A 83 12 140 9 1 1,000 The Pull-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per C. * Re-closure of Form B may occur if the max. coil voltage is exceeded. Coil polarity on Form B must be observed. Pin 2 is positive. Environmental Data Unit HE Reed Relay Shock Resistance (max.) 50 g 1/2 sine wave duration 11ms Vibration Resistance (max.) 20 g Operating Temperature -20 to 70 C Storage Temperature -35 to 105 C Soldering Temperature (max.) 260 C 5 sec. max. Handling & Assembly Instructions Switching inductive and/or capacitive loads create voltage and/or current peaks, which may damage the relay. Life Test Data Protective circuits need to be used. *Load increase reduces life expectancy of Reed Switches External magnetic fields needs to be taken into consideration, including a too high packing density. This may influence the relays electrical characteristics. Mechanical shock impacts e.g. dropping the relays may cause immediate or post-installation failure. Wave soldering: maximum 260/5 seconds. Reflow soldering: Recommendations given by the soldering paste manufacturer need to be considered as well as the temperature limits of other components/processes. USA: +1.866.782.6339 salesusa standexmeder.com Version 01 Europe: +49.7731.8399.0 info standexmeder.com 27.01.2015 Asia: +86.21.37820625 salesasia standexmeder.com Modifications in the sense of technical progress are reserved.