A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK02 Reed Sensors
MK02 Series
Reed Sensors
Features: Ferrous Metal Detection, Front or Above Operation, Choice of Cable Termination & Lengths
Applications: Door & Window Control, Fire Protection Doors, Safety & Interlock Sensing & Others
Markets: Appliance, Industrial, Security & Others
Part Description: MK 02 / 0 - 0 X00 -000 X
Operation Contact Contact Switch
Cable Length
Termination
(mm)
Series QTY Form Model
200, 300, 500, 1000, 1500,
0, 1, 2, 3, 4 01 A, B, C 66, 90 W
2000, 3000, 5000
Customer Options Switch Model
Unit
66 90
Contact Data
Rated Power (max.)
10 10 W
Any DC combination of V&A not to exceed their individual max.s
Switching Voltage (max.)
200 175 V
DC or peak AC
Switching Current (max.)
0.5 0.5 A
DC or peak AC
Carry Current (max.)
1.00 1.0 A
DC or peak AC
Contact Resistance (max.)
150 150 mOhm
@ 0.5V & 50mA
Breakdown Voltage (min.)
0.25 0.2 kVDC
According to EN60255-5
Operating Time (max.)
0.7 0.7 ms
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
0.05 1.5 ms
Measured with no Coil Excitation
Insulation Resistance (typ.)
10 9
10 10 GOhm
Rh<45%, 100V Test Voltage
Capacitance (typ.)
0.3 1.5 pF
@ 10kHz across open Switch
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK02 Reed Sensors
Housing and Cable Specifications MK02 Reed Sensor
Housing Material PBT Glass Fibre Reinforced
Case Color Blue
Sealing Compound Polyurethan
Cable Typ Round Cable
Cable Material PVC
Cross Section (mm) 4 x 0.14 / 2 x 0.25
Environmental Data Unit
Shock Resistance (max.)
50 g
1/2 sine wave duration 11ms
Handing & Assembly Instructions
Vibration Resistance (max.) 20 g
Operating Temperature
Max torque of screw is 1Nm
-5 to 80 C
Cable not moved
Cable bending-radius is diameter x 15
Operating Temperature
-30 to 80 C
Cable moved
Min. bending distance to housing is 5mm
Storage Temperature -30 to 80
C
Drag mark out of the mounting area forbidden
Decrease switching distance by mounting on iron
Glossary Contact Form Do not use magnetically inductive screws
NO = Normally Open Contacts Series resistor recommended for > 5m cable length
Form A
SPST = Single Pole Single Throw
NC = Normally Closed Contacts
Form B
Life Test Data
SPST = Single Pole Single Throw
*Load increase reduces life expectancy of Reed Switches
Changeover
Form C
SPDT = Single Pole Double Throw
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved.