A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK13 Reed Sensors
MK13 Series
Reed Sensors
Features: Standard Screw Fastening Reed Sensor with Cable Termination, Five Operation Sensitivities
Applications: End Motion Detection, Door/Flap Control, Hydraulic Actuator Position Indication & Others
Markets: Appliance, Industrial, Security & Others
Part Description: MK 13 - 0 X00 X -000 X
Contact Contact Magnetic
Cable Length
Switch Model Termination
(mm)
QTY Form Sensitivity
200, 300, 500, 1,000,
01 A, B, C 66, 75, 90 B, C, D, E W
1,500, 2,000, 3,000, 5,000
Customer Options Switch Model
Unit
66 75 90
Contact Data
Rated Power (max.)
10 10 10 W
Any DC combination of V&A not to exceed their individual max.s
Switching Voltage (max.)
200 230 175 V
DC or peak AC
Switching Current (max.)
0.5 0.5 0.5 A
DC or peak AC
Carry Current (max.)
1.0 1.0 1.0 A
DC or peak AC
Contact Resistance (max.)
150 200 150 mOhm
@ 0.5V & 50mA
Breakdown Voltage (min.)
0.25 0.4 0.2 kVDC
According to EN60255-5
Operating Time (max.)
0.7 0.5 0.7 ms
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
0.1 0.1 1.5 ms
Measured with no Coil Excitation
Insulation Resistance (typ.)
10 10 9
10 10 10 GOhm
Rh<45%, 100V Test Voltage
Capacitance (typ.)
0.3 0.4 1.5 pF
@ 10kHz across open Switch
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com
Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
www.standexmeder.com
Series Datasheet MK13 Reed Sensors
Housing and Cable Specifications MK13 Reed Sensor
Housing Material PBT Glass Fibre Reinforced
Case Color White
Sealing Compound Polyurethan
Cable Typ Flat Cable
Cable Material PVC
Cross Section (mm) 2 x 0.14 / 3 x 0.14
Environmental Data Unit
Shock Resistance (max.)
50 g
1/2 sine wave duration 11ms
Vibration Resistance (max.) 20 g
Operating Temperature
-30 to 70 C
Cable not moved Handling & Assembly Instructions
Operating Temperature
-05 to 70 C
Max torque of screw is 0,5Nm
Cable moved
Storage Temperature -30 to 70
C
Cable bending-radius is diameter x 15
Min. bending distance to housing is 5mm
Glossary Contact Form
Drag mark out of the mounting area forbidden
NO = Normally Open Contacts
Form A
Decrease switching distance by mounting on iron
SPST = Single Pole Single Throw
Do not use magnetically inductive screws
NC = Normally Closed Contacts
Form B
SPST = Single Pole Single Throw
Series resistor recommended for > 5m cable length
Changeover
Form C
SPDT = Single Pole Double Throw
Life Test Data
*Load increase reduces life expectancy of Reed Switches
Glossary Magnetic Sensitivity
Sens. A B C D E F G
AT 05-10 10-15 15-20 20-25 25-30 30-35 35-40
USA: +1.866.782.6339 salesusa@standexmeder.com
Version 01
Europe: +49.7731.8399.0 info@standexmeder.com
27.01.2015
Asia: +86.21.37820625 salesasia@standexmeder.com