A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components Series Datasheet SIL Reed Relays www.standexmeder.com SIL Series Reed Relays Features: Dual In-Line IC Compatible Relay, Available with Dielectric Strength 4.25VDC Applications: General Purpose, Measuring and Testing Devices & Others Markets: Telecommunications, Test and Measurement, Security & Others Part Description: S I L 00 - 0 X00 -00 X Nominal Contact Switch Contact QTY Pin Out Option Voltage Form Model 03, 05, 12, L, M, D, Q 1 A, B, C 31, 72, 75, 90 71, 72, 73, 74, 15, 24 (HR = High Resistance Version) Switch Model Customer Options Unit Contact Data 31 72 75 90 Rated Power (max.) 50 10 10 10 W Any DC combination of V&A not to exceed their individual max.s Switching Voltage (max.) 500 200 500 175 V DC or peak AC Switching Current (max.) 0.5 0.5 0.5 A 2 DC or peak AC Carry Current (max.) 1.0 1.0 1.2 A 2 DC or peak AC Contact Resistance (max.) 80 100 200 150 mOhm 0.5V & 50mA Breakdown Voltage (min.) 2,1 0.25 0.6 0.2 kVDC According to EN60255-5 Operating Time (max.) 0.5 0.5 0.7 ms 1,2 Incl. Bounce Measured with w/ Nominal Voltage Release Time (max.) 1 0.1 0.1 1.5 ms Measured with no Coil Excitation Insulation Resistance (typ.) 10 10 9 1010 10 10 10 GOhm Rh<45%, 100V Test Voltage Capacitance (typ.) 0.3 0.4 1.0 pF 0,3 10kHz across open Switch USA: +1.866.782.6339 salesusa standexmeder.com Version 01 Europe: +49.7731.8399.0 info standexmeder.com 27.01.2015 Asia: +86.21.37820625 salesasia standexmeder.com Modifications in the sense of technical progress are reserved. A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components Series Datasheet SIL Reed Relays www.standexmeder.com Coil Data Coil Voltage Coil Resistance Pull-In Voltage Drop-Out Voltage Nominal Coil Power Contact Switch (nom.) (typ.) (max.) (min.) (typ.) Form Model Unit VDC Ohm VDC VDC mW 05 80 3.5 0.75 312 31 12 500 8.4 1.8 288 03* 500 2.1 0.45 18 05 500 (200) 3.5 0.75 50 (125) 1A 72, 75 12 1,000 8.4 1.8 145 15 2,000 10.5 2.2 110 24 2,000 16.8 3.6 290 05 HR 1,000 3.5 0.75 25 72 12 HR 2,000 8.4 1.8 70 1B, 05 200 3.5 0.75 125 90 1C** 12 1,000 8.4 1.8 145 The Pull-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per C. * Coil Voltage 03 only available with Switch Model 72. **Contact Form 1C90 only available with Coil Voltage 05 () Data in () are valid for Switch Models 75 and 84. Environmental Data Unit SIL Reed Relay Shock Resistance (max.) 50 g 1/2 sine wave duration 11ms 20 g Vibration Resistance (max.) Operating Temperature -20 to 70 C Storage Temperature -35 to 95 C Soldering Temperature (max.) 260 C 5 sec. max. Handling & Assembly Instructions Switching inductive and/or capacitive loads create voltage and/or current peaks, which may damage the relay. Life Test Data Protective circuits need to be used. *Load increase reduces life expectancy of Reed Switches External magnetic fields needs to be taken into consideration, including a too high packing density. This may influence the relays electrical characteristics. Mechanical shock impacts e.g. dropping the relays may cause immediate or post-installation failure. Wave soldering: maximum 260/5 seconds. Reflow soldering: Recommendations given by the soldering paste manufacturer need to be considered as well as the temperature limits of other components/processes. USA: +1.866.782.6339 salesusa standexmeder.com Version 01 Europe: +49.7731.8399.0 info standexmeder.com 27.01.2015 Asia: +86.21.37820625 salesasia standexmeder.com Modifications in the sense of technical progress are reserved.